Dynascan LeakVIE M016 Manual de usuario

LeakVIEW
D016-047-1
USER GUIDE
Seal Integrity & Leak Detection Systems
FOR USE WITH MODEL NUMBERS:
M016-011 (Automatic IVG - Size 1)
M016-012 (Automatic IVG - Size 2)
M016 LeakVIEW

D016-047-1 LeakVIEW User Guide Page 2 of 22
CONTACT INFORMATION
For technical assistance or servicing, in the initial instance please contact your
supplier.
Manufactured by:
Cambridge Sensotec Ltd.
29 Stephenson Road
St. Ives
Cambridgeshire
PE27 3WJ
United Kingdom
Dynascan is the leak detection brand of Cambridge Sensotec Ltd
Tel: +44 (0) 1480 462142
Email: info@dynascan.co.uk
Website: www.dynascan.co.uk
© 2018 Cambridge Sensotec Ltd. Document number D016-047-1 (Feb 2018)
SUPPLIED BY:
Serial Number:
CONTACT INFORMATION

D016-047-1 LeakVIEW User Guide Page 3 of 22
SAFETY INSTRUCTIONS
• Do not subject the test chamber to differential temperature fluctuations.
• Disconnect the power supply before opening the connection box.
• Do not allow any liquid to come in contact with any electrical component.
• The system must only be filled with water that is of a temperature not greater
than the ambient temperature as the test chamber.
• Do not subject the test chamber to shock, especially when under vacuum.
• Do not allow the test chamber to come into contact with substances that can
attack the acrylic.
• Do not allow the weight of the test chamber to rest on the drain tap.
• Do not exceed the stated air supply pressure.
• Do not exceed the stated vacuum level.
• Do not attempt to relocate the system when it is filled with liquid.
• The compressed air supply should be isolated when not in use.
• This manual should be read and understood in its entirety before installation
or operation of the LeakVIEW system.
SAFETY INSTRUCTIONS

D016-047-1 LeakVIEW User Guide Page 4 of 22
SPECIFICATIONS
CONTROLS
Control Front Panel:
Touch screen display
START Button.
STOP / RESET Button.
Run / Program key.
Power indicator.
Control Rear Panel:
Power switch.
TECHNICAL
Vacuum control range – 200 to -800 mbars.
SIZE
M016-011
External dimensions: Height = 553mm, Width = 510mm, Depth = 430mm.
Internal Test Chamber dimensions: Height = 255mm (*175mm), Width = 440mm, Depth = 310mm).
* Base to clamp plate dimension
M016-012
External dimensions: Height = 643mm, Width = 625mm, Depth = 500mm.
Internal Test Chamber dimensions: Height = 330mm (*260mm), Width = 500mm, Depth = 330mm.
Pressure Plate to Base Height = 175mm.
* Base to clamp plate dimension
CONTROLLER
External dimensions: Height = 235mm, Width = 430mm, Depth = 345mm.
WEIGHT
M016-011 = 45kg (Dry).
M016-012 = 65kg (Dry).
CONTROLLER = 7kg
OPERATING TEMPERATURE
15-40C (Storage 0-50C).
ELECTRICAL SUPPLY
230 V, 50Hz. 300 VA.
COMPRESSED AIR SUPPLY
6.5 bar (7 bar max.) 8mm Push-in connection.
Capacity : >150l/min
MANUFACTURING STANDARDS
CE Marked.
SPECIFICATIONS

D016-047-1 LeakVIEW User Guide Page 5 of 22
SPECIFICATIONS
DECLARATION OF CONFORMITY
Name of manufacturer or supplier: Cambridge Sensotec Limited
Full postal address including country of origin: 29 Stephenson Road
Saint Ives
Cambridgeshire
PE27 3WJ
United Kingdom
DECLARATION OF CONFORMITY
We Cambridge Sensotec under our sole responsibility declare that the product listed below:
Description Category: BUBBLE EMISSION PACK TESTING DEVICE (CONTROLLER)
Model Designation (s): M016-020
Serial Number: ____________
Conforms to the principle safety objectives of the European Directive 2006/95/EC by application of the following
standard: EN 61010-1:2010
Conforms to the protection requirements of European Directive 2004/108/EC by application of the following stand-
ard: EN 61326: 2006 (industrial).
Year of affixation of the CE Marking 2018
Place of issue: St. Ives
Name of authorised Representative: Mark Swetnam
Position of authorised Representative: Managing Director
Signature of authorised representative
Date 29th March 2018

D016-047-1 LeakVIEW User Guide Page 6 of 22
1.1 INTENDED USE
The LeakVIEW is a package testing system based on the Pharmaceutical industry standard Bubble
Emission test method. The unit may also be used without water, where the visible leakage of pack
contents may be observed.
The system is intended for use in laboratory and manufacturing environments.
1.2 OPERATING PRINCIPLE
The LeakVIEW comprises a test chamber and vacuum generator controller. The vacuum and test time
may be programmed and monitored on the control panel. The test chamber is filled with water (enough
to cover the perceived range of packs when they are inflated), alternatively the test chamber may be
left empty for tests where visible pack content leakage is observed or for burst testing.
For a standard bubble emission test the following sequence takes place:
1. The packs are placed in the chamber and the lid is closed. This causes the pressure plate to
submerge the pack.
2. The operator presses the START button. This causes the air supply to the vacuum generator to
be switched on for the EVACUATION phase.
3. When the target vacuum is achieved, the vacuum generator is switched off and the system en-
ters then vacuum HOLD phase, where the vacuum will be held constant.
4. The operator observes the pack for any bubble stream due to a pin hole or seal defects.
5. When the test time has elapsed, the system enters the VENT phase and the vacuum is de-
stroyed, the lid can then be opened and the pack removed.
INTRODUCTION
SECTION 1: INTRODUCTION
This section describes:
• What the LeakVIEW unit should be used for
• The operating principle
• LeakVIEW unit features and benefits

D016-047-1 LeakVIEW User Guide Page 7 of 22
2.1 TYPOGRAPHICAL CONVENTIONS
The following conventions are used in this document:
2.2 WARNINGS, CAUTIONS AND NOTES
A WARNING indicates a potentially hazardous situation, which if not avoided may
result in injury.
A CAUTION indicates where a failure to observe an instruction or precaution could
result in equipment damage or undesirable operation.
A NOTE indicates important information that helps the operator make better use of
the equipment.
CAPITALS Status indicator names (where applicable)
BOLD CAPS Switch (switch) names (where applicable)
CONVENTIONS
SECTION 2: CONVENTIONS
This section describes:
• The typographical conventions
• Warnings, cautions and notes
WARNING
CAUTION
NOTE

D016-047-1 LeakVIEW User Guide Page 8 of 22
3.1 UNPACKING
The LeakVIEW is supplied in a packing crate that should be retained should the unit require returning
to the supplier. The crate side and top faces should be removed. The base unit should be unpacked
first and located in its final position. The test chamber can then be unpacked and placed on the base
unit. It is suggested that a small screw or bottle jack with a padded contact area is placed centrally
within the base unit. The chamber can then be lifted onto this and then lowered into position.
If the test chamber is supplied with its fittings attached, do not allow the weight of the
chamber to bare down on the drain tap fitted to the base. The test chamber is also
heavy, this may require two people to lift it. Ensure body parts are kept clear of the
base of the chamber when it is being lowered into position.
3.2 POSITIONING
The Test Chamber should be positioned, such that it is level and subjected to minimal vibration or
movement, A position that affords an all-round view would be an advantage. The supporting surface
must be able to withstand the weight of the system when filled with water. Access to the drain tap
should also be considered. The Controller Unit should be placed to one side of the Test Chamber such
that the front panel controls are in easy reach.
INSTALLATION
SECTION 3: INSTALLATION
This section describes:
• How to unpack the LeakVIEW
• Positioning of the LeakVIEW unit
Figure 3.1
CAUTION
Drain tap position.

D016-047-1 LeakVIEW User Guide Page 9 of 22
INSTALLATION
3.3 ELECTRICAL SUPPLY
The power lead (supplied) must be connected to an AC supply as specified on the rating plate located
next to the IEC power inlet connector.
This equipment must be connected to a protective earth (grounded power supply).
3.3.1 POWER SUPPLY FUSE
There is a single fuse fitted inside the fuse holder within the IEC mains connector on
the rear panel. Replace with the same specification fuse. The LeakVIEW fuse type
and rating is a T type (Anti-surge) with a 5 Amp rating. See Fig 3.2.
CAUTION
3.3.2 MAINS SWITCH
The mains switch is incorporated within the IEC mains connector. It is a rocker type switch and is la-
belled 1 for ON and 0 for OFF. It is advisable to switch the unit off when not in use (Fig 3.2).
Figure 3.2
Fuse location.

D016-047-1 LeakVIEW User Guide Page 10 of 22
INSTALLATION
3.4 PNEUMATIC SUPPLY
An air supply of 6 bar (7bar max) should be connected to the Air Supply connection port on the rear
panel. This air supply must be dry and oil free.
Ensure the air supply is connected to the correct port. Provision must be made to iso-
late the air supply in an emergency.
3.5 TEST CHAMBER CONNECTIONS
The Vacuum and Sense tubing from the test control unit should be connected to the ports on the lid of
the Test Chamber. These are push-fit couplings and are free to rotate.
WARNING
Figure 3.4
Air Supply
Vacuum Line
Sense Line
Figure 3.3
Example of a push-fit connection.
Este manual sirve para los siguientes modelos
2
Tabla de contenidos