dymax ECE ZIP Shutter Manual de usuario

ECE ZIP™ Shutter
For Use with Dymax ECE Flood Lamp Systems
Instructions for Safe Use
Setup and Operation
Maintenance
Ordering Spare Parts and Accessories

2
Dymax ECE ZIP™ Shutter User Guide
About Dymax
UV/Visible light-curable adhesives. Systems for light curing, fluid dispensing, and fluid packaging.
Dymax manufactures industrial adhesives, light-curable adhesives, epoxy resins, cyanoacrylates, and activator-cured adhesives.
We also manufacture a complete line of manual fluid dispensing systems, automatic fluid dispensing systems, and light-curing systems.
Light-curing systems include LED light sources, spot, flood, and conveyor systems designed for compatibility and high performance
with Dymax adhesives.
Dymax adhesives and light-curing systems optimize the speed of automated assembly, allow for 100% in-line inspection, and increase
throughput. System designs enable stand-alone configuration or integration into your existing assembly line.
Please note that most dispensing and curing system applications are unique. Dymax does not warrant the fitness of the product for the
intended application. Any warranty applicable to the product, its application, and use is strictly limited to that contained in the Dymax
standard Conditions of Sale. Dymax recommends that any intended application be evaluated and tested by the user to ensure that desired
performance criteria are satisfied. Dymax is willing to assist users in their performance testing and evaluation by offering equipment trial
rental and leasing programs to assist in such testing and evaluations. Data sheets are available for valve controllers or pressure pots upon
request.

3
Dymax ECE ZIP™ Shutter User Guide
Contents
Introduction.................................................................................................................................................... 4
Introduction to the User Guide ....................................................................................................................................... 4
Where to Get Help .......................................................................................................................................................... 4
Safety.............................................................................................................................................................. 4
General Safety Considerations ........................................................................................................................................ 4
Specific Safety Considerations......................................................................................................................................... 5
Product Overview ........................................................................................................................................... 5
Description of the ECE ZIP Shutter................................................................................................................................... 5
System Components........................................................................................................................................................ 6
Assembly and Setup........................................................................................................................................ 7
Unpacking and Inspecting Your Shipment....................................................................................................................... 7
Parts Included in the ECE ZIP Shutter (PN 40885)............................................................................................................ 7
Installation and System Interconnect.............................................................................................................................. 8
Operation ..................................................................................................................................................... 11
Maintenance................................................................................................................................................. 12
Check and Adjust Curtain Drive-Belt Tension................................................................................................................ 12
Shutter Curtain Assembly Replacement........................................................................................................................ 13
Troubleshooting............................................................................................................................................ 14
Spare Parts and Accessories.......................................................................................................................... 15
Specifications................................................................................................................................................ 16
Systems Specifications (Clear Aperture)........................................................................................................................ 16
Definition of Terms ....................................................................................................................................... 17
Warranty ...................................................................................................................................................... 18
Index............................................................................................................................................................. 19

4
Dymax ECE ZIP™ Shutter User Guide
Introduction
Introduction to the User Guide
This guide describes how to assemble, use, and maintain the ECE ZIP™ Shutter safely and efficiently.
Intended Audience
Dymax prepared this user guide for experienced process engineers, technicians, and manufacturing personnel.
If you are new to UV light curing and do not understand the instructions, contact Dymax Application
Engineering to answer your questions before using the equipment.
Where to Get Help
Dymax Customer Support and Application Engineering teams are available in the United States, Monday
through Friday, from 8:00 a.m. to 5:30 p.m. Eastern Standard Time. You can also email Dymax at
[email protected]. Contact information for additional Dymax locations can be found on the back cover of this
user guide.
Additional resources are available to ensure a trouble-free experience with our products:
Detailed product information on www.dymax.com
Dymax adhesive Product Data Sheets (PDS) on our website
Material Safety Data Sheets (MSDS) provided with shipments of Dymax adhesives
Safety
WARNING! If you use a Dymax shutter without first reading and understanding the
information in this user guide, injury can result from exposure to high-intensity light. To reduce
the risk of injury, read and ensure you understand the information in this user guide before
assembling and operating a Dymax shutter in a UV flood lamp system.
General Safety Considerations
All users of Dymax equipment should read and understand this user guide before assembling and using the
equipment.
To learn about the safe handling and use of light-curable formulations, obtain and read the MSDS for each
product. Dymax includes an MSDS with each adhesive sold. In addition, fluid product MSDS can be requested
through our website.

5
Dymax ECE ZIP™ Shutter User Guide
Specific Safety Considerations
Dymax shutters are designed to maximize operator safety and minimize exposure to UV light. To use the
shutter safely, it must be set up and operated in accordance with the instructions in this user guide. Please
also read and understand the following safety considerations.
WARNINGS! To prevent eye injury, always wear protective goggles when working near a UV
light-curing system.
Long-sleeved shirts or a lab coat are recommended to protect the arms and use of UV opaque
gloves will protect the hands from UV exposure.
Product Overview
Description of the ECE ZIP Shutter
Dymax shutters were developed as auxiliary devices to improve operator safety and to control the dose of
curing energy directed onto adhesives in a flood-lamp curing systems. The ECE ZIP Shutter is compatible with
Dymax ECE 2000 and ECE 5000 flood lamps. The shutter can be used as an integral part of the Dymax ECE light
shield.
Dymax flood lamps use a medium-pressure arc bulb as a source of curing energy. The bulb requires a few
minutes to warm up after ignition before it reaches a steady state and needs a few minutes to cool before
being able to re-ignite after being turned off. Repeatedly turning the power to the bulb off and on negatively
affects its lifetime. With a Dymax shutter installed, the flood lamp may stay on continuously. Objects needing
curing may be loaded and unloaded from underneath the shutter when it is closed without exposing parts or
operators to UV light. In addition, control of curing times can be achieved by timed shutter operation.
Dymax flood lamp systems are used for a wide variety of applications where a relatively large area of
illumination is needed. These applications may be cured using one of two types of systems: the first is with
continuous illumination in conveyorized curing systems where the dose is defined by the conveyor belt speed.
The second type uses a free-standing flood lamp where accurate timing is required. In the second type, the
shutter can ensure the proper dose.

6
Dymax ECE ZIP™ Shutter User Guide
System Components
Figure 1. ECE ZIP Shutter Component Diagram
Digital Potentiometer (Timer) (1) - The operator sets the shutter’s “open time”using the digital
potentiometer (timer) on the control panel. The shutter’s “open time” can be set from 1 to 99
seconds.
Actuate Button (2) - Depressing the actuate button activates the gear motor inside the shutter. The
unit can also be actuated by foot switch. The foot switch can be connected to the foot switch
connection (5) on top of the rear panel.
Mode Selector Rocker Switch (3) - There are two operation modes available: manual and timed.
The mode selector rocker switch is used to select the mode of operation.
Mounting Plates/Adapter Plates - The ZIP Shutter includes two mounting plates for various reflector
housings. The first has a clear aperture of 5" x 5" and should be used with the ECE 5000. The second
has a clear aperture of 8" x 8" for use with an ECE 2000. The ZIP Shutter has a clear aperture,
therefore there is no distraction of the light flow when the shutter is open.
Reflector Cable Connection (4) - The power (24V) to the ZIP Shutter comes directly from the flood
lamp’s power supply, which is connected through this receptacle on top of the shutter’s rear panel.
Belt Tension Adjustment Screw (6) - Used to tighten the curtain drive belt.

7
Dymax ECE ZIP™ Shutter User Guide
Assembly and Setup
Unpacking and Inspecting Your Shipment
When your ECE Zip Shutter arrives, inspect any boxes for damage and notify the shipper immediately of box
damage.
Open each box and check for equipment damage. If parts are damaged, notify the shipper and submit a claim
for the damaged parts. Contact Dymax so that new parts can be shipped to you immediately.
Check that the parts included in your order match those listed below. If parts are missing, contact your local
Dymax representative or Dymax Customer Support to resolve the problem.
Parts Included in the ECE ZIP Shutter (PN 40885)
ECE ZIP Shutter (1)
Dymax Shutters for ECE Systems User Guide (2)
Interconnect Cable (3) - Connects the Shutter to the Flood Lamp
Foot Switch (4)
Brackets (5) - Connect the ECE Shutter to the ECE Light Shield
Tools & Hardware - M4 x 25 mm Screws (6), M4 x 8 mm Screws (7), & Hex Wrench (8)
Mounting Plates - for the ECE 2000 (9) & ECE 5000 (10)
Plenum Assembly for the ECE 5000 (11)
Figure 2. ECE Zip Shutter Components

8
Dymax ECE ZIP™ Shutter User Guide
Installation and System Interconnect
NOTE: Setup of the ECE flood lamps is covered in the ECE-series user guides. Refer to MAN045 –ECE-Series
Flood Lamp User Guide.
ECE 5000 Flood Lamp
1. Remove the Mounting Plate from the ZIP Shutter by removing the four M4 x 8 mm flat head screws (Figure 3).
Figure 3. ECE ZIP Shutter with Mounting Plate Installed
NOTE: If the ZIP Shutter and the Lamp Assembly are NOT installed into a Light Shield, the Glass
Containment Shield must be installed.
2. Install the Glass Shield (if applicable). Follow the instructions below:
Remove the Filler Plate from the Reflector Housing and install the glass on the Reflector Housing
edges.
Replace the Filler Plate and screws securely.
Figure 4. Reflector Housing with Filler Plate
Figure 5. Reflector Housing, Filler Plate
Removed
3. Place the Mounting Plate onto the Reflector Housing (Figure 6) and then place the Air Plenum on top of
the Mounting Plate (Figure 7). Attach all three components together with four new M4 x 25 mm screws.
M4 x 8 mm Flat Head Screws
Mounting Plate

9
Dymax ECE ZIP™ Shutter User Guide
Figure 6. Attach Mounting Plate to
Reflector Housing
Figure 7. Attach Air Plenum to Filler
Plate/Reflector Assembly
4. Install the Lamp Housing Assembly into the ZIP Shutter and attach it with four M4 x 8 screws (Figure 9).
NOTE: One side of the Filler Plate has a third screw hole (Figure 8). When in the correct position, this screw
hole will be at the rear of the Shutter.
Figure 8. Lamp Housing Assembly
Figure 9. ECE 5000 Lamp Housing
Assembly Installed with M4 x 8 Screws
Four M4 x 8 screws (two located on opposite side)
Third Screw Hole

10
Dymax ECE ZIP™ Shutter User Guide
ECE 2000 Flood Lamps
NOTE: If the ZIP Shutter and Lamp Assembly are NOT installed into a Light Shield, the Glass Containment Shield
must be installed.
1. Install the Glass Shield (if applicable) (Figure 10).
2. Install the ECE 2000 Mounting Plate on the base of the ECE 2000 Lamp Housing (Figure 11) by installing
the M4 x 8 mm screws.
3. Install the Glass Shield (if applicable).
Figure 10. Reflector Housing with Glass
Shield Installed
Figure 11. Lamp Housing with
Mounting Plates Installed
4. Install the Lamp Housing Assembly into the ZIP™ Shutter and attach it with four M4 x 8 mm screws
(Figure 13).
NOTE: One side of the Mounting Plate has a third screw hole (Figure 12). When in the correct position, this
screw hole will be at the rear of the Shutter.
Figure 12. Lamp Housing Assembly
Figure 13. ECE 2000 Lamp Housing
Assembly Installed with M4 x 8 Screws
Four M4 x 8 screws (two located on opposite side)
Third Screw Hole
Tabla de contenidos
Otros manuales de Equipo de iluminación de dymax
Manuales populares de Equipo de iluminación de otras marcas

Qazqa
Qazqa Suplux SL 3 Black 103062 Manual de usuario

Commercial Electric
Commercial Electric 54568141 Manual de usuario

CREE LIGHTING
CREE LIGHTING 304 Series Manual de usuario

Goobay
Goobay 49867 Manual de usuario

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manual de usuario

Alkalite
Alkalite Krypton KT-81 Manual de usuario