diversey TASKI swingo 760E Manual de usuario



2
Translation of the original instructions of use
Legend:
Content
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Cleaning products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Further documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Structural layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Prior to commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Beginning work with the machine . . . . . . . . . . . . . . . . . . . . . . . 7
End of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Service, maintenance and care. . . . . . . . . . . . . . . . . . . . . . . . . 10
Malfunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Transport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Machine dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Intended use
The machine is intended for commercial use (e.g. in hotels,
schools, hospitals, factories, shopping centers, offices, etc.).
Subject to strict compliance with the instructions of use, these
machines are used for the wet cleaning of hard flooring.
These machines are exclusively designed for use in interior
zones.
Safety instructions
Due to their design and construction, TASKI machines comply
with the relevant essential health and safety requirements of
the EC directives; they therefore have the CE sign.
CAUTION!
Always read the instructions of use and
the safety instructions before using the
machine for the first time.
The instructions of use must be kept in a
safe and well accessible place so that
you can refer to them at any time.
Caution:
This sign designates important informa-
tion. Failure to follow these instructions
may result in danger to persons and/or ex-
tensive damage to property!
Attention:
This sign designates important informa-
tion. Failure to follow these instructions
may result in faults and damage to proper-
ty!
Notice:
This sign designates important information
regarding the efficient use of the product.
Failure to follow these instructions may re-
sult in faults!
It includes instructions for the work steps that
you must carry out in order.
t
Attention:
The machine must not be used for polish-
ing, oiling, the application of wax, carpet
cleaning or dust removal. The wet clean-
ing of parquet and laminate flooring with
this machine is at your own risk.
Caution:
Changes to the machine that have not
been authorized by Diversey will lead to
the expiry of safety marks and CE confor-
mity. Using the machine for purposes oth-
er than the intended purpose can cause
injuries to persons, and damage to the ma-
chine and the working environment. Such
cases will usually result in the termination
of any warranty and possible guarantee
claims.
Caution:
The machine may only be used by per-
sons who are adequately trained for the
use of the machine or who have provided
proof of their skills regarding the use of the
machine and who are explicitly commis-
sioned to use the machine.
Caution:
The machine must not be used by people
with reduced physical, sensory or mental
capacities, including children or people
who lack experience or knowledge.
Children must be supervised to ensure
that they do not play with the machine.
Caution:
Do not use the machine in rooms where
explosive or highly combustible substanc-
es (e.g. gas, solvents, heating fuel, dust,
etc.) are stored or processed.
These substances could be ignited by the
electrical or mechanical components of
the machine.

3
Caution:
Do not use the machine for the vacuum
cleaning of poisonous, harmful, caustic or
irritating substances (e.g. dangerous dust,
etc.). The filter system does not adequate-
ly filter out these kinds of substances.
Possible impacts on the health of the user
or third persons cannot be ruled out.
Caution:
Pay attention to the local situation as well
as to third persons and children! In the vi-
cinity of blind spots such as doors or
curves in particular, it is important to re-
duce speed.
Caution:
Do not transport other persons and objects
with this machine.
Caution:
In case of malfunction or defect or after
collisions or toppling over, the machine
must be inspected by an authorized expert
before restarting. The same applies if the
machine was left outdoors, immersed in
water or subjected to moisture.
Caution:
The machine must be stopped immediate-
ly in case of damage to safety relevant
parts such as brush covers, power supply
cords or covers that enable access to live
parts.
Caution:
The machine must not be stopped, parked
or stored on slopes.
Caution:
The machine must be switched off for any
work carried out on the machine.
Caution:
Do not use the machine in rooms with high
electromagnetic interference (electric
smog).
Caution:
The machine must not be used on slopes
>2%.
Sharp cornering on slopes can affect the
stability of the machine and is therefore
prohibited. Danger of accident.
Attention:
The machine must be protected against
unauthorized use. Therefore, keep the
machine in a locked room before leaving it.
Attention:
Operate and keep the machine in a dry
and low-dust environment at temperatures
between +10°C / + 50 °F and +35°C/ + 95
°F degrees only.
Attention:
Only authorized experts who are familiar
with all safety instructions relevant for this
machine are allowed to repair mechanical
or electrical machine parts.
Attention:
Only tools (brushes, pads or similar) that
are specified in these instructions of use
under accessories, or which have been
recommended by a TASKI consultant,
may be used. Any other brushes might im-
pair the safety and functions of the ma-
chine.
Attention:
National regulations for personal protec-
tion and accident prevention as well as the
manufacturer's instructions for the use of
cleaning solutions must be consistently
observed.
Attention:
It is forbidden to plug in or unplug the main
power supply cord with wet hands!
Attention:
Make sure that the rated voltage stated on
the machine label is the same as the volt-
age rating of the plug socket!
Attention:
Take care not to damage the power supply
cord by rotating tools (brushes, pads or
similar), crimping, tearing or damaging the
power supply cord through heat, oil, or
sharp objects!
Attention:
In case of foam or liquid leakage from the
machine, the suction unit must be
switched off immediately.
Attention:
TASKI machines and devices are de-
signed such that health risks caused by
noise emissions or vibrations can be ruled
out according to the current state of sci-
ence.
See the technical data on page 12.
EN

4
Cleaning products
Further documents
Notice:
TASKI machines are designed in such a
way that optimal cleaning results can be
achieved if TASKI cleaning products are
used.
Other cleaning products may cause mal-
functions and damage to the machine or
the environment.
Therefore, we recommend the exclusive
use of TASKI cleaning products.
Faults caused by inappropriate cleaning
products are not covered by the guaran-
tee.
For further details, please contact your
TASKI service partner.
Notice:
The electric diagram of this machine is
provided in the spare parts list.
Please contact your customer service for
further information.

5
Structural layout
1Switch bracket drive
2Driving handles
3Operating hour counter (option)
4Drain hose cleaning solution (blue cover)
5Drain hose waste water (red cover)
6Water regulating set
7Foot pedal tool
8Foot pedal squeegee
9Squeegee
10 Tools (brushes, pads, etc.)
11 Brush unit
12 Cleaning solution switch
13 Suction unit switch
14 Main switch
15 Fresh water tank filter
16 Recovery tank
17 Float (Overfill protection recovery tank)
18 Suction filter
19 Dirt sieve
20 Solution tank
21 Dosage aid
22 Tank lid
23 Tank lid unlocking
8
910
7
6
2
3
4
5
1
14
13
12
11
20 1921
15
16
17
18
23
22
max.60°C
max.140°F
EN

6
Prior to commissioning
Brush installation
Before inserting, please check:
• that the brush does not fall below the red marking (bristles)
or 1cm of bristle length.
• the pad for wear and cleanliness before use.
Squeegee assembly
Filling the fresh water tank
Attention:
Do not use brushes which have reached
their wear limit. The wear limit is indicated
by the length of the red bristle. Do not use
worn or contaminated pads. Use original
TASKI brushes only. Failure to observe
these instructions may result in inade-
quate cleaning results or even floor dam-
age.
• The machine must be switched off (main switch).
• Position the tools under the tool unit.
• Plug the power supply cord into the mains socket.
• Switch on the machine (key switch).
Switch lights up
• Unlock the foot pedal and lower the
tool slowly.
• Briefly press the operating lever.
In this way the tool is centered and engaged.
Notice:
Lightly moving the machine backwards
and forwards at the driving handle helps it
to engage.
• The machine must be switched off (main switch).
• Position the squeegee (2) below the
squeegee holder (1).
• Press the foot pedal down until the
squeegee holder engages.
• Attach the suction hose to the con-
nector.
Attention:
Max. permissible water temperature
60 °C/140 °F.
Diversey recommends using cold water
since hot water will adjust to the floor tem-
perature as soon as it is in contact with the
floor. Thus there are no advantages to us-
ing hot water.
• The machine must be switched off.
• Put your hand into the opening be-
tween tank cover and tank.
Palms upwards.
• Open the tank cover until the support engages in the tank
wall.
• Remove the dosage aid.
• Fill the fresh water tank with water.
Maximum filling level (page 5).
• Tip the tank cover back into its original position and press
it down until it locks.
1
22
1

7
Dosing
Dosage cup application
Pre-cleaning
Beginning work with the machine
Cleaning start
Attention:
Wear gloves, goggles and appropriate
(protective) working clothes when han-
dling chemical products!
Notice:
Use chemical products recommended by
Diversey only and always observe the
product information.
Caution:
Using unsuitable products (e.g. products
containing chlorine, acids or solvents) may
cause harm to health and severe damage
to the machine.
Notice:
For a precise dosage, use the scale in the
dosage cup.
The filling level mark on the tank corre-
sponds to the mark in the dosage cup. The
type of machine is also noted in the dos-
age cup!
Information on
the package of
the product
Tank capacity Dosage cup
0.5% 1/2 1 x 1/2
MAX 1 x MAX
1% 1/2 1 x MAX (2 x 1/2)
MAX 2 x MAX
• Fill the product you have measured with the dosage cup
into the fresh water tank.
• Slightly lift the tank cover.
• Push the tank cover support slightly inwards.
• Close the tank lid.
• By pushing gently on the front part of the tank cover you
lock the tank.
Attention:
Remove any objects (wooden, metal parts
etc.) from the cleaning surface.
The objects could be catapulted by the ro
-
tating tool, and thereby cause injuries to
people and damage to the environment.
Attention:
Always wear slip-resistant shoes and ap-
propriate working clothes when working
with this machine!
Attention:
Start familiarization with the machine by
making your first driving attempts in a free
area.
• Lower the squeegee.
• Plug the power supply cord into the mains socket.
• Switch on the machine (key switch).
Switch lights up
• Unlock the foot pedal and lower the
tool slowly.
• Switch off the suction unit.
Switch lights up
• Switch off the water pump.
Switch lights up
• Use the quantity control to dose the
cleaning solution.
• Pull the switch bracket drive on the
driving handle.
The tool starts to rotate and the
cleaning solution supply starts.
EN

8
Cleaning method
Direct working method:
Scrubbing and suction in one work step.
Indirect working method:
Applying the cleaning solution, scrubbing and suction in sev-
eral work steps.
Replenishing cleaning solution
Soiled water full
Recovery tank full:
End of operation
Notice:
More precise details regarding the direct
and indirect working method can be found
on the respective method sheet.
Please contact your TASKI customer con-
sultant for further details.
Notice:
The machine guiding might be impaired in
case of special combinations of flooring/
contamination and cleaning product.
Optionally available wheels can improve
the traction of the machine on the floor.
Please contact your TASKI customer con-
sultant.
Attention:
The flooring may be damaged when work-
ing without cleaning solution.
Notice:
A rattling sound of the pump indicates that
the fresh water tank is empty.
Attention:
The pump must never run dry for an ex-
tended period.
• The machine must be switched off.
• Open the tank lid.
• Fill the fresh water tank with water, see page 6.
• Add the cleaning product using the dosing cup.
• Close the tank lid.
• If the recovery tank is full, the floater
will be sucked onto the suction filter.
This will be indicated by a change of
the noise by increasing the suction
speed as well as residual water at the
bottom.
• Drain the recovery tank, see page 9.
• Switch off the water pump.
The cleaning solution supply is
stopped.
• Continue to drive a few meters.
Notice:
Very important for TASKI contact pads!
• To lift the tool, push the foot pedal
downwards until it engages.
• Drive on for a few meters in order to absorb the remaining
drain water.
• Switch off the suction unit.
The switch lights up; the suction en
-
gine stops.
• Switch the machine off (ON/OFF)
and pull the power supply cord out of
the mains socket.
Attention:
The machine must now be emptied and
cleaned. Switch off the machine (main
switch) and remove the plug from the
mains socket.
Tabla de contenidos
Idiomas:
Otros manuales de Máquina de piso de diversey

diversey
diversey Taski ergodisc 2000 Manual de usuario

diversey
diversey TASKI swingo 1655 XD Manual de usuario

diversey
diversey TrailBlazer Guía del usuario

diversey
diversey TASKI swingo 1260B Power Manual de usuario

diversey
diversey swingo 4000 Manual de usuario

diversey
diversey TASKI swingo 1260B Power Manual de usuario

diversey
diversey Taski swingo XP CO75XP.2 Manual de usuario