If attachingthePowerhouse to a pipeor postusing the pipe bracket, first ensurethe pole isstrong enoughto support the
weight ofthePowerhousethen proceedas follows:
•
Establish the correct position for the MightylitePro on the pipe ensuring the wirescaneasily reachthe unit.
•
Positionthepipe bracketandU bracketaroundthepipeand secureusingappropriatenuts boltsand washers(included),
as shown in[Fig.5].
•
OfferthePowerhouseup to the U bracketandsecureusingthe securing bolts, springwashersand washers
provided [Fig.2].
•
Loosen the 4 screwsholdingthe front of the connection box in place, and remove.
•
Feedthewirethroughthecablegland,gentlytighteningglandnutupagainsttheglandbody[Fig.4]to ensurethe
wire(s)is secured in placeand no water can get though into the connection box.
•
Wire the Powerhouse as described in Section4.
•
Oncethepowercablehasbeenfedthroughthecable gland,approximately6mmof insulationshouldbestripped
from each of the coresof AC cablereadyto attachit to theterminalblock in the front of the lightfitting.
NOTE: The Diodor LED Powerhouse DIO-FL120W-WM and DIO-FL200W-WM areClass1 fittings and therefore needto be
Earthed
4.1 CONNECTING TO POWERSUPPLY
IMPORTANT:DiodorLEDPowerhouse hastwodualchanneldriverswhichcontrolthe4LEDarrays withintheMightylitePro.
ThefourBROWN(Live)wiresinthePowerhouseterminal,eachoperateas theLiveforeachoftheLEDarrays,enablingthe
arraystobe wiredto beswitched onandoffindependentlyofeachother(SeeSection4.2WiringOptions).ThetwoBLUE
(Neutral)wiresintheterminaloperateastheNeutralforeachofthedrivers.
Theunitis suppliedwithall4wireslinkedinto2 terminalswhichare,in turn,connectedby asingleBROWNwire.Towirethe
unitsoall4LEDarraysoperatetogetherfromasingleswitch(SingleLevelwiring)proceedasfollows:
•
ConnecttheBROWNorRED(Live)wiretoeitherterminal(marked“L”)holding2BROWNwiresinthefloodlightunit,
and linked together by a singleBROWN wire[Fig.6].
•
ConnecttheBLUEor BLACK(Neutral)wiretotheterminal(marked“N”)holdingthe2BLUEwiresinthefloodlightunit
[Fig.6].
•
ConnecttheYELLOW/GREENorBARE(Earth)wiretotheterminal(marked“EARTH”)holdingtheYELLOW/GREEN
wire in the floodlightunit
Note:OneswitchoperatesthePowerhouse whichis always
atfullpower(100%lightlevel)whenswitchedon. Note: One switch operates two of the Powerhouse LED arrays,
and another controls the other two arrays, enabling the unit to
operate at 50% or 100%power dependenton switching.
3.2. OPTION
2: ATTACHING THE Diodor LED Powerhouse VIA THE PIPE BRACKE
T
4. WIRING THE
FLOODLIGHT
4.2
WIRING OPTIONS
7
Live
Neutral