10
5- START UP
Make sure that the mains voltage is between 110 and 230 V.
Connect the power cable to the rear plug and to the network.
Consult the indicative flow table and install the appropriate tube.
See tips in the Tube Change and Head Description section.
Select the desired function.
OPERATING MODES.
Available modes:
A- Pumping mode.
B- Ramp mode.
Programming.
Access to the use of the Ramp.
C- Cyclic dosing mode.
Programming.
Access to the use of Cyclic Dosing
D- Pedal dosing mode.
Programming.
Access to the use of Dosage with pedal.
· Pumping mode.
This mode is used to work with the pump continuously, to transfer liquids.
If the pedal is connected, while it is pressed, the head will work, if it is released, the head will stop.
1- Activate rear switch nº1 Pphoto a) O/1.
2- Activate the front switch nº7 (Photo a), it will light up in blue and the display will turn on.
3- Select the motor speed in % by pressing the decrease or increase keys nº5 or nº6(Photo a).
4- If it is necessary to change the direction of rotation, press keys no. 1 or no. 2 (Photo a).
5- Press the No. 4 (Photo a) Start / Stop key to start pumping. To stop pumping, use the same key
no. 4 (Photo a).
If we have the pedal connected, we can start pumping by pressing key no. 4 (Figure a) or by
keeping the pedal pressed. Working with the pedal, the pump will stop when we stop pressing the
pedal.
6- The equipment can be programmed so that if there is a power outage, when it is restored, it
continues to work at the speed that has been programmed. To program this function and at the
speed at which it should resume operation, press key no. 4 (Photo a) for 5 seconds. Its pilot light
will flash and with keys no. 5 or no. 6 (Photo a) we will enter the speed at which we want it to
work if there is a power cut and it is restored, it will be memorized by simply pressing key no. 4
(Photo a) Start / Stop.
To make loading, purging or cleaning tasks easier, press key no. 3 (Photo a) Full. The speed will
progressively increase to the maximum and we will see how it increases on the display up to 99. Pressing
the Full key again will recover the programmed speed, lowering the display to that speed.