Digitus Biometrics db ProxLock Manual de usuario

db ProxLock
Installation Manual

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 2 of 10
Table of Contents
Determining which Lock Pawl to use .......................................................................................... 3
Overview ......................................................................................................................... 4
Securing the Door Lock Step 1 ............................................................................................... 5
Mount the tie down pads to the Door and Cabinet – Step 2 ................................................................ 6
Route the Cable between the lock and the door hinge – Step 3 ............................................................ 7
Connect the cable to the Remote Node / db Sentry Controller – Step 4 ................................................... 8
Connect the db ProxLock to a 3
rd
party access control panel (ACM) – Step 5 .............................................. 9

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 3 of 10
Determining which Lock Pawl to use
•As all cabinets vary, we offer a wide range to pawls to suit the particular dimensions of your cabinet.
•If new pawls are required, there is a simple measurement that needs to be taken to determine which pawl you will
need. Using the existing mechanical lock, measure the length of “H” in millimeters (mm) as shown in figure 1. Using
“H” determine which pawl is required from Table 1.
•Once the correct pawl model has been determine, please contact our lock support team on +1 912 231 8175
Figure 1
Standard Pawl Pawl with Rod Control
H (mm)
Model #
H (mm)
Model #
4 1000 112 4 1000 U63
6
1000
22
6
1000
U21
8 1000 113 8 1000 U64
10
1000
21
10
1000
U22
13 1000 20 13 1000 U23
14
1000
19
14
1000
U24
16 1000 18 16 1000 U25
18
1000
17
18
1000
U26
20 1000 16 20 1000 U27
22 1000 15 22 1000 U28
24
1000
14
24
1000
U29
25 1000 27 25 1000 U30
26
1000
50
26
1000
U31
28 1000 13 28 1000 U32
30
1000
28
30
1000
U33
32 1000 26 32 1000 U34
34
1000
12
34
1000
U35
35 1000 11 35 1000 U36
36
1000
51
36
1000
U37
38 1000 52 38 1000 U38
40 1000 25 40 1000 U39
42
1000
53
42
1000
U40
44 1000 54 44 1000 U41
45
1000
10
45
1000
U42
47 1000 55 47 1000 U43
50
1000
56
50
1000
U44
Table 1
In most situations the pawl from the existing mechanical handle can be re-used with the new lock.

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 4 of 10
Overview
•If you are installing the lock into to a cabinet that already has a lock installed, remove the existing lock at this time.

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 5 of 10
Securing the Door Lock - Step 1
•
Secure the lock to the door using the top mounting bracket and bottom mounting bracket as show in Figure 1. Do
not over tighten the screws in the bottom mounting bracket as this may jam the lock mechanism.
•Page 3 of this document describes how to determine which pawl you will need, depending on the make and model
of cabinet.
•Pay particular attention to the rotation limiter. This is installed as shown depending on whether you have a right on
left hand opening door.
Pawl
Rotation Limiter
Figure 1
Note. Do not use an electric screwdriver to tighten the screws.

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 6 of 10
Mount the tie-down pads to the Door and Cabinet – Step
•The ties down pads are used to secure the supplied 6’ cable from the lock to the door hinge.
•Ensure that the door surface is clean and free from any debris. (Using neat alcohol to clean the surface is highly
recommended. Allow drying time before proceeding.)
•Remove the protective cover from each tie down pad and situate as shown in Figure 2.
Figure 2

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 7 of 10
Route the Cable between the lock and the door hinge – Step 3
•Route the cable as show in Figure 3. Secure the cable to the tie down pads using the supplied cable ties.
Figure 3

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 8 of 10
Connect the cable to the Remote Node / db Sentry Controller – Step 4
Connect the RJ45 coupler to the RJ45 plug on the cable coming from the db ProxLock
Use the Digitus Application to connect between the RJ45 coupler and the Node or Sentry device.
Note that is a door needs to
be fully removed at any time, the lock can be unplugged from the RJ45 coupler, and re attached once the door is replaced.
Locks are connected to the Remote Node or db Sentry’s socket circled in the diagram below.
Each Remote Node / db Sentry Controller has two device inputs, Dev 1 and Dev 2.
Side View of Remote Node
Side View of db Sentry
It is recommended that for a cabinet with 2 doors, the front door is connected to Dev 1 and the back door is connected to
Dev 2.
If the db ProxLock is being connected directly to a
rd
-party access control panel, rather than Digitus
control equipment, skip straight to Step 5

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 9 of 10
Connect the db ProxLock to a 3
rd
-party access control panel (ACM) – Step 5
Orange/White – GND, Ground
Orange – LOCK CTRL. Requires a 12V (24V if a 24V version of the db ProxLock was purchased) control line to
unlock the handle
Green/White – Wiegand DATA 1
Blue – V+, Requires a 12VDC Supply
Blue/White – LATCH POS (used to indicate if lock is open or closed) – Will be pulled to Ground (GND) if the handle is closed.
Will be open circuit if the handle is open. See diagram below
Green – Wiegand DATA 0
Brown/White – No connection
Brown – No connection
If the db ProxLock is being connect to a Digitus Node or Sentry, this step is not required.

Model: db ProxLock Version: May 2017 Digitus Biometrics, nc. 2017
Page 10 of 10
Digitus Biometrics, Inc.
2 East Bryan Street, Suite 502
Savannah, GA 31401 USA
Phone: 912 231 8175
Fax: 912.629.9478
www.digitus biometrics.com
support@digitus biometrics.com
Specifications subject to change without notice.
Tabla de contenidos
Otros manuales de Cerradura de puerta de Digitus Biometrics