DeWalt XR FLEXVOLT DCB500-QS Manual de usuario

DCB500
Final print size: A6 (105mmx148mm)

English (original instructions) 3
Copyright
DeWALT

1
Fig. A
1
2
8
3
Fig. B 2
3
4
5

2
Fig. C
Fig. D
73
6

ENGLISH
3
English (original instructions)
CORDED POWER SUPPLY
DCB500
Congratulations!
You have chosen a
DeWALT
tool. Years of experience, thorough product development
and innovation make
DeWALT
one of the most reliable partners for professional power
toolusers.
Technical Data
DCB500-QS DCB500-GB DCB500-LX DCB500-XE
Power source AC AC AC AC
Type 1111
Max. current A16 13 16 10
Mains voltage VAC 230 230 115 230
Weight kg 1.1 1.1 1.1 1.1
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please read the
manual and pay attention to thesesymbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will
result in death or seriousinjury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could
result in death or seriousinjury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderateinjury.
NOTICE: Indicates a practice not related to personal injury which, if not avoided,
may result in propertydamage.
Denotes risk of electricshock.
Denotes risk offire.
WARNING: Read all safety warnings and all instructions. Failure to follow the
warnings and instructions may result in electric shock, fire and/or seriousinjury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE

4
ENGLISH
Safety Rules for the Corded Power Supply
DANGER: High voltage present inside the unit. Do not probe with conductive
objects. Danger of electric shock or electrocution.
DANGER: If the corded power supply case is cracked or damaged, do not plug
into AC outlet or insert into tool. Return the unit to an authorized
DeWALT
service
center. Danger of electric shock or electrocution.
DANGER: The corded power supply and power tool may produce a small
magnetic field. Users with cardiac pacemakers should keep the corded power
supply and power tool at least 15cm away from implanted device. Users
should immediately stop using this product, remove power, and call physician
if any physical effects are felt.
WARNING: We recommend the use of a residual current device with a residual current
rating of 30mA or less.
WARNING: Review and follow all instructions and warnings contained within
the tool's instruction manual connected with the corded power supply
manual. Failure to follow the warnings and instructions may result in electric shock,
fire and/or serious injury.
• Do not use under wet conditions or in presence of flammable liquids or gases.
• Do not expose corded power supply to rain or snow.
• Use of an attachment not recommended or sold by
DeWALT
may result in a risk of fire,
electric shock, or injury to persons.
• This corded power supply is not intended for any uses other than powering D
eWALT
2x54V
FLEXVOLT™ tools. Any other uses may result in risk of fire, electric shock or electrocution.
• Pull by the plug rather than the cord when disconnecting the corded power
supply. This will reduce the risk of damage to the electric plug and cord.
• Make sure that the cord is located so that it will not be stepped on, tripped over or
otherwise subjected to damage or stress.
• Do not use an extension cord unless it is absolutely necessary. Use of improper
extension cord could result in risk of fire, electric shock or electrocution.
• When operating the corded power supply outdoors, always provide a dry location
and use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor
use reduces the risk of electric shock.
• Do not force the corded power supply. Use the correct power tool for your application.
• Avoid body contact with earthed or grounded surfaces, such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is
earthed or grounded.

5
ENGLISH
• Do not operate the corded power supply with damaged cord or plug. In case
of damaged power supply cord, the supply cord must be replaced immediately by the
manufacturer, its service agent or similar qualified person to prevent any hazard.
• Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled
cords increase the risk of electric shock.
• Do not operate corded power supply if it has received a sharp blow, been dropped,
or otherwise damaged in any way. Take it to an authorised service centre.
• Do not store or use the tool and battery pack in locations where the temperature may
reach or exceed 40 ˚C.
NOTICE: Under certain conditions, with the corded power supply plugged into the
power supply, the corded power supply can be shorted by foreign material. Foreign
materials of a conductive nature such as, but not limited to, grinding dust, metal
chips, steel wool, aluminum foil, or any buildup of metallic particles should be kept
away from corded power supply. Always unplug the corded power supply from the
power supply when not connected to the tool. Unplug the corded power supply before
attempting to clean.
Electrical Safety
The
DeWALT
corded power supply may be used on all 2x54V FLEXVOLT™tools with a
current rating less than or equal to the current rating shown on the
DeWALT
corded power
supply rating label. Always check that the power supply corresponds to the voltage on the
rating plate of the corded power supply.
Your
DeWALT
corded power supply is double insulated in accordance with
EN62841; therefore, no earth wire isrequired.
WARNING: 115 V units have to be operated via a fail-safe isolating transformer with
an earth screen between the primary and secondary winding.
If the supply cord is damaged, it must be replaced by a specially prepared cord available
through the
DeWALT
serviceorganisation.
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
• Safely dispose of the oldplug.
• Connect the brown lead to the live terminal in theplug.
• Connect the blue lead to the neutralterminal.
WARNING: No connection is to be made to the earthterminal.

6
ENGLISH
Follow the fitting instructions supplied with good quality plugs. Recommended fuse: 13A.
Using an Extension Cable
An extension cord should not be used unless absolutely necessary. Use an approved
extension cable suitable for the power input of your charger (see Technical Data). The
minimum conductor size is 1.5mm2; the maximum length is30m.
When using a cable reel, always unwind the cablecompletely.
SAVE THESE INSTRUCTIONS
Package Contents
The package contains:
1 Corded power supply
1 Instruction manual
• Check for damage to the tool, parts or accessories which may have occurred
duringtransport.
• Take the time to thoroughly read and understand this manual prior tooperation.
Markings on Corded Power Supply
The following pictograms are shown on the tool:
Read instruction manual before use.
Date Code Position (Fig. A)
The date code 8, which also includes the year of manufacture, is printed into thehousing.
Example:
2016 XX XX
Year of Manufacture
Description (Fig. A–D)
WARNING: Never modify the power tool or any part of it. Damage or personal injury
couldresult.
1 AC connector
2 Release button
3 Cord clip
4 Dust cover (Fig.B)
5 Tool's corded power supply AC
connector receptacle (Fig.B)
6 Dust cover holder (Fig.C)
7 Tool's cord clip holder (Fig.D)

7
ENGLISH
Intended Use
This corded power supply is designed for professional use in
DeWALT
2x54V FLEXVOLT™
tools.
DO NOT use or store under wet conditions or in the presence of flammable liquids orgases.
DO NOT let children come into contact with the tool. Supervision is required when
inexperienced operators use thistool.
• Young children and the infirm. This appliance is not intended for use by young
children or infirm persons without supervision.
• This product is not intended for use by persons (including children) suffering from
diminished physical, sensory or mental abilities; lack of experience, knowledge or skills
unless they are supervised by a person responsible for their safety. Children should
never be left alone with thisproduct.
Introduction
The DCB500
DeWALT
corded power supply is designed to provide power for
DeWALT
2x54V FLEXVOLT™ cordless tools.
Your
DeWALT
corded power supply should only be used with a power supply
corresponding to the voltage on the rating plate of the DCB500, and not with DC
powersources.
The DCB500 corded power supply is suitable for use with double insulated 2x54V
FLEXVOLT™ cordless tools.
Additional Specific Usage Instructions
The corded power supply may become warm to the touch during use. This is a normal
condition and does not indicate a problem.
IMPORTANT. The power supply is not user serviceable. There are no user serviceable
parts inside the power supply. Cord replacement may be conducted at an authorized
servicecentre.
Installing and Removing the Corded Power Supply into and
from Tool (Fig.B–D)
Before inserting the corded power supply into your tool, remove the end of the dust cover
(4, Fig.B) from the tool's corded power supply receptacle if applicable. Pull the dust cover
away from the tool’s corded power supply receptacle so that it does not interfere with
insertion of the corded power supply. Inspect the tool's corded power supply receptacle for
debris. Debris inside the receptacle can prevent the corded power supply from fully seating.
If debris is present, clean it using low pressure air or vacuum cleaner. Refer to tool manual.

8
ENGLISH
WARNING: To minimize the risk of eye injury, always wear ANSI Z87.1 approved eye
protection and respiratory protection when performing this.
NOTICE: The corded power supply is for AC power sources only when used with
a tool. Use with DC power sources could result in damage to the tool.
To install the corded power supply into your tool
• With the corded power supply unplugged, align its AC connector 1 with the tool's
corded power supply receptacle (5, Fig.B) then snap into place.
• Ensure that it is fully seated in the tool and does not disengage.
• If applicable, attach the dust cover 4 to the dust cover holder (6, Fig.C) in the corded
power supply.
• Secure the cord clip 3 into the tool's cord holder (7, Fig.D), if applicable. Firmly press
the clip into the holder.
• With the tool turned off, plug the corded power supply into a standard 230V household
electric power outlet. UK 115V units should be plugged into a 115V transformer. Do not
attempt to use the corded power supply on any other voltage.
• Use the tool according to the tool instructions, making sure the cord is located so that it
will not be stepped on, tripped over, or otherwise subjected to damage or stress.
• To remove the corded power supply from the tool (Fig.B), first unplug the corded
power supply from the outlet, then press the release button 2 and firmly pull the
corded power supply out of the tool. If applicable, firmly press the end of the dust cover
4 into the tool’s corded power supply receptacle 5.
MAINTENANCE
The corded power supply is not serviceable. There are no serviceable parts inside the
corded power supply.
Do not attempt to repair the corded power supply. To assure product safety and reliability,
repairs, maintenance, and adjustments should be performed by authorized
DeWALT
service
centers. Your
DeWALT
corded power supply has been designed to operate over a long
period of time with a minimum of maintenance. Continuous satisfactory operation depends
upon proper care and regularcleaning.
WARNING: To reduce the risk of serious personal injury, turn tool off and disconnect
battery pack before making any adjustments or removing/installing attachments or
accessories. An accidental start-up can causeinjury.
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Otros manuales de Fuente de alimentación de DeWalt