DESMOCAL LED PAR LIGHT Manual de usuario

LED PAR LIGHT
USER MANUAL
DESMOCAL, S.L.
Murcia ( Spain)
Tels.: 968850439 & 617339732
968850439 & 617339732968850439 & 617339732
968850439 & 617339732
WWW.BLACKHAWK
WWW.BLACKHAWKWWW.BLACKHAWK
WWW.BLACKHAWK-
--
-SPAIN.COM
SPAIN.COMSPAIN.COM
SPAIN.COM
Email.:
Email.:Email.:
Email.: desmocal@desmocal.com
desmocal@desmocal.com desmocal@desmocal.com
desmocal@desmocal.com
CONTENTS
BEFORE YOU BEGIN………………………………………3

What is included…………………………………………………………3
Unpacking Instructions…………………………………………………3
AC Power………………………………………………………………3
Safety Instructions………………………………………………………3
INTRODUCTION………………………………………………4
Specifications…………………………………………………………4
Features…………………………………………………………4
SETUP
……………………………………………………5
Installation Requirement…………………………………………5
T h e i n s t a l l a t i o n a n d u s a g e o f g l a r e
s h i e l d … … … … … … … … … … … … 5
Connection of power……………………………………………5
Connection of DMX Signal Wire………………………………6
OPERATING INSTRUCTIONS……………………………6
Control Panel Functions…………………………………………………6
Menu Map…………………………………………………………7
Operating instructions……………………………………………………8
DMX512 Controller Mode………………………………………8
DMX512 Channel Values………………………………………9
ID Address Instructions………………………………………………11
Master/Slave Control Mode…………………………………………12
C o n t a c t
Us…………………………………………………13
BEFORE YOU BEGIN
What is included
1 x Fixture
1 x DMX signal cable
1 x User Manual

Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton; check the contents to
ensure that all parts are present, and have been received in good condition. Notify the
shipper immediately and retain packing material for inspection if any parts appear
damaged from shipping or the carton itself shows signs of mishandling. Save the carton
and all packing materials. In the event that a fixture must be returned to the factory, it is
important that the fixture be returned in the original factory box and packing.
AC Power
This fixture has an auto-switching power supply that can accommodate a wide range of input
voltages. The only thing necessary to do before powering on the unit is to make sure the line
voltage you are applying is within the range of accepted voltages. This fixture will
accommodate between 100V and 240V AC 50-60 Hz.
Safety Instructions
This light belongs to grade I protection device, therefore the light must connect to the earth
excellently. And the power connection must be operated by the professional technician.
Make sure that the working voltage will not higher or lower than the rated value.
Make sure that the cable didn’t be damage or lacerated by sharp.
The light must be power off when it’s standing idle or before clearing.
The cable must with plug, and you must pull out the cable by handle the plug.
Please be careful when installing the lighting. Never touch the bared cable, or it will cause
the deadly electric shock.
Please never look at the beam directly, or it will hurt your eyes.
The light must keep a distance at least 0.5m with the projected objects.
Please use the suitable and safe cable to connect the light.
Please never remodel the light randomly, we will not take the guarantee for the faulty and
damage which caused by dismantle、repair or remodel of the nonprofessional person.
Maximum ambient temperature 40°C. Do not operate fixture at temperatures higher than
this.
Never connect the device to a dimmer pack.
INTRODUCTION
Specifications
Voltage Rating:AC100V~240V□
Power Rating: 40W/120W
LED Quantity: 36LEDs (12R+12G+12B)
LED: 350 mA /700mA
Beam Angle: 15°/30°
Product Size: 270×220×300mm
Package Size: 290x290x370 mm
N/W: 3.2KG
G/W: 4.1KG
Features

RGB color mixing with or without DMX controller
5 distinct dimming curves
User defined program/ inner optional program
Strobe/Fade-in & Fade-out/RGB mixing/ ID intelligent addressing
LED display with password protection
Transfer custom programs between fixtures
Operating Modes: DMX512 Connection with ID Address/Master & Slave...
DMX Channels: STAG/ col.d…
10channels:RGB+ Dimmer + Macro + strobe + AUTO + Auto speed +
dimming speed +ID
4 channels:RGB + Dimming
SETUP
Installation Requirement
This product can be used in a variety of situations, can hang and put on the ground.
If hanging the fixture for over head use, then please follow the below steps.
Please choose the suitable location to put or hang the light when installing it. You
must use the exclusive clamp hanger and screw when hanging it, and make sure
the weight of the light is within limits of the hanger.
Please make sure without any flammable objects within 0.5m when installing the
light.
The installation should be operated by professional person; any irregular installation
will cause the body injury or equipment damage.
Block access below the work area and use suitable and stable platform when
installing or servicing fixture.
Lamps must be placed in the ventilation position, at least 50 cm from the ground.
Make sure the ventilation holes without clogging.

POWER CONNECTION
This fixture has an auto-switching power supply ,The only thing necessary to do before
powering on the unit is to make sure the line voltage you are applying is within the
range of accepted voltages. This fixture will accommodateAC100V~240V 50-60 Hz.
Connection of DMX Signal Wire