Delsys TRIGNO Manual de usuario

TRIGNOTM Wireless System
User’s Guide
Feb. 2009 Edition
Copyright © 2009 by Delsys Incorporated
Specifications and procedures outlined in
this document are subject to change
without notice.
Delsys Logo, EMGworks, and Myomonitor
are Registered Trademarks of Delsys
Incorporated.
MAN-012-1-0


1
Table of Contents
Table of Contents .............................................................. 1
Important Information ....................................................... 3
Intended Use .......................................................................... 3
Contraindications.................................................................... 3
Technical Service and Support............................................... 3
Warnings and Precautions...................................................... 4
Device Information.................................................................. 5
Disclaimer............................................................................... 7
Limited Warranty..................................................................... 7
TrignoTM Wireless EMG System...................................... 8
TrignoTM System Components........................................ 9
Wireless EMG Sensor ............................................................ 9
Sensor LED Indicator Status ...................................................... 9
Base Station ......................................................................... 10
Power Supply........................................................................ 10
Sensor Adhesive Skin Interfaces.......................................... 11
Getting Started with the TrignoTM System................... 12
Powering the Base Station ................................................... 12
Charging the Sensors........................................................... 12
Turing the Sensor ON........................................................... 12
Using EMGworks with the TrignoTM System....................... 13
Using the Wireless EMG Sensors ........................................ 14
Orienting the EMG Sensors on the Skin................................... 14
Using the Delsys Adhesive Sensor Interface ........................... 15
Maintenance and Care..................................................... 16
Trigno Sensors ..................................................................... 16
Recharging Base Station...................................................... 16
Specifications .................................................................. 18
Trigno Sensors ..................................................................... 18
Trigno Recharging Base Station........................................... 19

2 Trigno Wireless System User’s Guide

3
Important Information
Intended Use
The TrignoTM Wireless EMG Systems are designed for research,
investigational and scholarship purposes only. Delsys®products
are not intended for measurement purposes or for use in the
treatment and diagnosis of humans.
Rx ONLY
Contraindications
Technical Service and Support
For information and assistance visit our web site at:
www.delsys.com
Contact us at:
E-mail: [email protected]m
tel: (617) 236 0599
DO NOT USE on Patients with implanted electronic devices of
any kind, including cardiac pace-makers or similar assistive
devices, electronic infusion pumps, and implanted stimulators.
DO NOT USE on irritated skin or open wounds.
DO NOT USE on Patients with allergies to Silver.

4 Trigno Wireless EMG System User’s Guide
TM
Warnings and Precautions
Consult all accompanying documents for precautionary statements and
other important information.
Consult accompanying user’s guide for detailed instructions.
Keep the device dry. The presence of liquids may compromise the
safety features of the device.
Handle with care.
Sensitive electronic device. Avoid static discharges. Do not operate or
store near strong electrostatic, electromagnetic, magnetic or radioactive
fields. Interference from external sources may decrease the signal-to-
noise ratio or result in corrupted data.
Connect only to Delsys-approved devices.
Connecting a patient to high-frequency surgical equipment while using
Delsys EMG systems may result in burns at the site of the EMG sensor
contacts.
Immediately discontinue device use if skin irritation or discomfort
occurs.
Immediately discontinue device use if a change in the device’s perfor-
mance is noted. Contact Delsys technical support for assistance.
Delsys Inc. guarantees the safety, reliability, and performance of the
equipment only if assembly, modifications and repairs are carried out by
authorized technicians; the electrical installation complies with the
appropriate requirements; and the equipment is used in accordance with
the instructions for use.
Device contains a Lithium-Polymer battery. Do not damage, crush,
burn, freeze or otherwise mishandle the device. Recharge only with the
approved power supply and recharger.
Trigno Systems should be stored and operated between 5 and 50 degrees
Celsius due to the presence of an internal Lithium Polymer rechargeable
cell. Storing or operating the device, and consequently the cell, outside
of this temperature range may compromise the integrity and the safety
features of the cell.

5
Device Information
Complies with Requirements put forth by the Medical Device Directive
93/42/EEC. Class I device, Annex VII.
Type BF device (IEC 60601-1).
Isolated device, (Class II, IEC 60601-1)
Do not dispose this product with house waste. Contact Delsys Inc. for
instructions on responsibly disposing this device. This product should
not be mixed with other commercial wastes.
Date of Manufacturing (appears on device)
Serial Number (appears on device)
FCC ID: W4P-SP-W02 (Trigno Base Station)
FCC ID: W4P-SP-W01 (Trigno Sensor)
IC: 8138A-DST01 (Trigno System)
This device complies with Part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may not cause
harmful interference. and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This product complies with FCC OET Bulletin 65 radiation exposure
limits set forth for an uncontrolled environment.
Changes not expressly approved by Delsys Inc.could void the User’s
authority to operate the equipment
REPEC
EMERGO EUROPE
Molenstraat 15
2513 BH, The Hague
The Netherlands
DELSYS INC.
650 Beacon St.
Boston MA 02215
USA
Authorized Representative Manufacturer

6 Trigno Wireless EMG System User’s Guide
TM
To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radi-
ated power (EIRP) is not more than that required for successful commu-
nication.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. There is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which canbe determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into outlet on a separate circuit.

7
Disclaimer DELSYS INC. makes no warranties, express or implied, as to
the quality and performance of this product including but not
limited to, any implied warranty of applicability for other than
research uses by qualified individuals. DELSYS INC. shall not
be liable to any person for any medical expenses or any direct or
consequential damages resulting from any defect, failure or mal-
function, whether a claim for such damages is based upon theory
of warranty, contract, tort or otherwise. No representative, agent,
or licensed practitioner is authorized to waive this disclaimer.
DELSYS INC. makes no diagnosis or prescription by virtue of
anything about this product.
Limited Warranty
The TrignoTM Wireless EMG Systems are warranted against fail-
ure of materials and workmanship for a period of 1 year from the
date of delivery, provided that the product is given proper care
and has not been subject to abuse during this period. This war-
ranty is in lieu of all other warranties expressed or implied.
Operation of this device outside specifications determined by
DELSYS INC. or use with any other input devices other than
DELSYS INC. sensors constitute an invalidation of this limited
warranty. This warranty is not transferable.

8 Trigno Wireless EMG System User’s Guide
TM
TrignoTM Wireless EMG System
The TrignoTM Wireless EMG System is a high-performing
device unparalleled in its sophistication, its reliability and its
ease-of-use. Each EMG sensor has a built-in triaxial
accelerometer, a guaranteed transmission range of 20m and a
rechargeable battery lasting 7 hours. The system is capable of
streaming data to EMGworks Acquisition and Analysis software
and of generating 16 EMG and 48 accelerometer analog
channels for integration with motion capture and other 3rd party
data acquisition systems. Full triggering features further expand
the possibility for integration with additional measurement
technologies.
Figure 1. Complete Trigno Wireless System
1Wireless Sensor 5Analog Output Connectors
2Base Station 6Trigger Port
3USB Port 7Antenna
4Power Jack/Power Supply 8EMGworks Software
(not shown)
12
6
4
7
5
3
Otros manuales para TRIGNO
5
Tabla de contenidos
Otros manuales de Sistema de micrófono de Delsys
Manuales populares de Sistema de micrófono de otras marcas

Sennheiser
Sennheiser Evolution Wireless Digital EW-DX EM 2 Manual de usuario

Alpha Technologies
Alpha Technologies RBMS Manual de usuario

SWIT Electronics Co.,LTD.
SWIT Electronics Co.,LTD. CW-S150 Manual de usuario

Shure
Shure UA844 Manual de usuario

Panasonic
Panasonic SHFX70 - DVD HOME THEATER WIRELESS SYSTEM Manual de usuario

Pyle
Pyle PDWM5000 Manual de usuario