DCS DishDrawer DD124P5 Manual de usuario

MODELS:
DD124P5
DD224P5
DISHDRAWER®
Installation Guide

Important safety precautions!
Installation of this DishDrawer® requires basic mechanical and electrical skills.
Be sure to leave these Instructions with the Customer.
Installation must comply with your local building and electricity regulations.
At the completion of the DishDrawer® installation, the Installer must perform
Final Check List on Page 29.
Remove all packaging materials supplied with the DishDrawer®.
This dishwasher is manufactured for indoor use only.
Ensure all water connections are turned OFF. It is the responsibility of the plumber and
electrician to ensure that each installation complies with all Codes and Regulations.
The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is
required.
The switched power outlet must be outside the DishDrawer® cavity so that it is accessible after
installation.
Care should be taken when the appliance is installed or removed to reduce the likelihood of
damage to the power supply cord.
If the DishDrawer® is to be relocated from one installation to another it must be kept upright to
avoid damage from water spillage.
Make sure only new hoses are used for connection (supplied with DishDrawer®).
Old hoses should not be reused.
Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the
vehicle, boat or mobile facility containing the product to the service shop at your expense or pay
the service technician’s travel to the location of the product.
WARNING!
Cut Hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
Safety and warnings
WARNING!
Electrical hazard
Before installing the DishDrawer®, remove the house fuse or open the circuit
breaker.
If permanently connecting the DishDrawer®, be sure the power is isolated
and the DishDrawer® unplugged.
This appliance must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electric shock by providing
a path of least resistance for electric current. This appliance is equipped
with a cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is installed
and grounded in accordance with all local codes and ordinances. Improper
connection of the equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service representative if
you are in doubt as to whether the appliance is properly grounded.
Do not modify the power supply plug provided with the appliance - if it will
not fit the outlet, have a proper outlet installed by a qualified electrician. Do
not use an extension cord, adapter plug or multiple outlet box.
Failure to do so may result in electrical shock or death.
US CA

1
Contents
DOUBLE MODELS
Product and cabinetry dimensions
2
Installation
Cavity preparation
4
Optionally hard wiring the product
5
Route the hoses and move into the cavity
6
Removing the tub and levelling the product
7
Securing the product and refitting the tub
8
Fitting the toekick
9
Plumbing and drainage - OPTION 1
10
Plumbing and drainage - OPTION 1 (connection)
11
Plumbing and drainage - OPTION 2
12
Plumbing and drainage - OPTION 2 (connection)
13
Plumbing and drainage - OPTION 3
14
Plumbing and drainage - OPTION 3 (connection)
15
SINGLE MODELS
Product and cabinetry dimensions
16
Installation
Cavity preparation
18
Optionally hard wiring the product
19
Route the hoses and move into the cavity
20
Removing the tub and securing the product
21
Plumbing and drainage - OPTION 1
22
Plumbing and drainage - OPTION 1 (connection)
23
Plumbing and drainage - OPTION 2
24
Plumbing and drainage - OPTION 2 (connection)
25
Plumbing and drainage - OPTION 3
26
Plumbing and drainage - OPTION 3 (connection)
27
Refitting the tub
28
Final checklist
29
Important!
SAVE THESE INSTRUCTIONS
The models shown in this User Guide may not be available in all markets and are
subject to change at any time. For current details about model and specification
availability in your country, please go to our website www.dcsappliances.com or
contact your local DCS Customer Care Representative.
US CA

2
DOUBLE MODELS
US CA Product dimensions
Product dimensions (inches (mm))
Prenished
Flat door
DD224P5
Aoverall height* of product 32 ¼ - 34 ⁄”
(819.5- 879.5)
Boverall width of product 23 ⁄”(605)
Coverall depth of product (excl. curvature/handle) 22 ⁄” (570)
Ddepth of drawer (open) (excl. curvature/handle) 20 ⁄” (520)
Eheight* of chassis 31 ⁄” (809)
Fheight range of levelling feet 2 ⁄” (60)
Gdepth of chassis 21 ¾” (552)
Hdepth of drawer front panel (excl. curvature/handle) 1” (25)
Idepth of handle 3 ⁄” (81)
Jdepth of kickstrip 2 - 4 ⁄” (50 - 110)
Kheight of upper drawer front 15 ⁄” (398)
Lheight of lower drawer front 14” (356)
Mheight of kickstrip (adjustable) 2 ¾ - 4 ¾” (70 - 120)
Nheight of installation tab slots (on top of chassis) ¾” (2)
Oheight of drawer fronts 30 ⁄” (764)
Pheight* of top of upper drawer to top of chassis ¾” (2)
* Chassis heights include tab slots
O
B
C
E
D
F
G
H
J
N
P
I
K
L
M
A
N
G
C
I
Installation diagrams for illustration purposes only

3
DOUBLE MODELS
US CA
Cabinetry dimensions
A
B
C
D
E
Installation diagrams for illustration purposes only
Cabinetry dimensions (inches (mm))
Prenished
Flat door
DD224P5
Ainside height of cavity 32 ⁄ - 34 ¾”
(820 - 882.5)
Binside width of cavity 24”(610)
Cinside depth of cavity (inside) 22 ⁄”(580)
Dheight of adjacent cabinetry 28 ⁄”(720)
Eheight of kickstrip 2 ¾- 4 ¾” (70 - 120)
Minimum clearances (inches (mm))
⁄” (2.5 mm)
⁄” (2.5 mm)
½” (13 mm)

4
90o
2”x 4”
DOUBLE MODELS
US CA
Note: Services can be located
either side of DishDrawer®.
Cavity preparation
Parts supplied
Important!
Be sure the edges of the services hole are smooth or covered. If the service hole is through a metal partition
the hole must be protected with the Edge Protector supplied to prevent damage to the power cord or hoses.
These marks indicate mounting tab screw locations
Preferred position. If adequate clearance, services hole can be higher to clear toe kick space.
If hole is higher, ensure drain hose(s) are routed straight into the waste connection.
110-120 VAC
max. 15 A
Moisture
protection
tape must
be applied.
max. ø
1 ½” (
38 mm)
*
*
*
min.
7 ⁄”
(
200 mm)
Clamp (1)
Wire clip (2) Phillips
16 mm
screws (9)
Drain hose
support (1)
Moisture
protection
tape (1)
(to prevent
moisture damage)
Drain hose
joiner (1)
Install
tabs (2)
Prefinished toe kick (1)
White or Black
Washer (1)
Edge Protector (1)
(if service hole
partition is metal)
⁄”
(
10 mm)
max.
17 ⁄”
(
450 mm)
If no side partition,
use a brace for
securing.
If the Drain hose(s) supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit
P/N 525798 which will extend the drain hose(s) by 3.6m. The kit is available from the nearest DCS
Authorized Service Agent, or by phone: 1-888-281-5698, or www.dcsappliances.com. DO NOT extend beyond this limit.
Hexagonal
socket (2)
(Long & Short)
Side flexible
extrusions (2)
Top flexible
extrusion (1)

5
DOUBLE MODELS
US CA
Optionally hard wiring the product
30 mm
12
3
4
5
6
7
9
7
8
8
13
17
14
15
15
16
12
11
11
10
4
1 2
3
1 ⁄”
(
30 mm)
Ensure the tub is removed and
then rotated counter-clockwise
to prevent kinked hoses.
Before refitting the tub,
ensure the hoses are not
twisted and the latches at
the rear of each drawer
runner are facing forward.
Ensure the tub clips on
both sides are reset.
Ensure the tub is
now rotated
clockwise back.
Remove power supply cord.
Remove knock-out for cable
clamp. Fit suitable cable clamp for
the conduit and terminate the
wiring as shown.

6
DOUBLE MODELS
US CA
2
3
1
1
1
2
4
4
optional
1b
2
optional
1a
Tie together to avoid kinking.
Route the hoses and move into the cavity
If top two tabs are being used,
ensure they’re securely fitted
before sliding product into
cavity.
Ensure hoses and cord
are not kinked or twisted.
Loosen feet first, but
do not fully extend
until product is in cavity.
Side
extrusion
Lip
Chassis
trim
edge
Flexible
extrusions
Open drawer
If cavity is bigger than
specified (Pg 3), flexible
extrusions can be stuck along
the top and sides of the product.
Ensure extrusions do not prevent
the drawer from closing completely.

7
DOUBLE MODELS
US CA
Removing the tub and levelling the product
30 mm
x 4
1
2
3
4
5
5
123
4
5
3
4
Ensure the tub is removed and
then rotated counter-clockwise
to prevent kinked hoses.
Ensure product is level. Using the most appropriate length
Hexagonal socket supplied, and a screwdriver, fully extend
levelling feet up to required distance.
Hexagonal socket

8
DOUBLE MODELS
US CA Securing the product and retting the tub
A
1
2
4
5
4
3
CC
BB
A
5
optional
6
max.
¾” (19 mm)
The mounting tabs
are in pairs, one on
each side of the
product. At least two
sets of tab pairs must
be used.
Aand Btab pairs
OR Band Ctab pairs
or all three pairs.
Ensure the sound
insulation is
repositioned
correctly.
Before refitting the tub,
ensure the hoses are not
twisted and the latches at
the rear of each drawer
runner are facing forward.
Ensure the tub clips on
both sides are reset.
Ensure the tub is
now rotated
clockwise back.
Otros manuales para DishDrawer DD124P5
3
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas:
Otros manuales de Lavavajillas de DCS

DCS
DCS DishDrawer DD24 series Manual de usuario

DCS
DCS DishDrawer DD24DUT7 Manual de usuario

DCS
DCS DishDrawer DD124P5 Manual de usuario

DCS
DCS DishDrawer DD224P5 Manual de usuario

DCS
DCS DishDrawer DD124 Series Manual de usuario

DCS
DCS DD24SUT Manual de usuario

DCS
DCS DishDrawer DD24DUT7 Manual de usuario

DCS
DCS DishDrawer DD24 series Manual de usuario

DCS
DCS DishDrawer DS224 Series Manual de usuario

DCS
DCS DD124-C Manual de usuario