Dear Daxom User, For correct operation and safety of this
device, follow the instructions in this manual during installation
and use. Unauthorised assembly or maintenance of this
device will void the warranty, and our company will not be
responsible for any defects or accidents that may occur with
the product. Please keep this instruction manual in good
condition for future reference.
1. The boiler must be installed by qualified tradespeople
(electrician/plumber) according to the instructions in this
manual.
2. The boiler must initially be started up by a qualified
technician , do not attempt to start the device yourself.
3. The boiler must be safely and securely connected to the
water and heating system .
4. Ensure that the mains voltage is correct. (Please note:
Depending on the model, the voltage specified may differ)
5. If using an external electricity source ( (such as a generator)
safe operation of the boiler must be ensured.
6. Install the appliance with the appropriate diameter cable
specified in this manual. The boiler needs to be connected via
a MCB/RCD as outlined in this instruction manual and secure
earth grounding needs to be in place for safe operation.
7. This appliance should not be installed in humid or external
environments.
8. Do not store flammable or explosive substances or articles
near the appliance.
1. SAFETY WARNINGS
2

9. This installation and operating manual is part of the product.
Keep it for reference.
10. This boiler should only be used for its intended purpose.
The manufacturer rejects all contractual or non-contractual
obligations in advance for damage to property or injury to
persons or animals resulting from misuse, installation,
adjustment and maintenance.
11.After removing the packaging, make sure all parts are
included and in good condition. If parts are missing or
damaged, contact the retailer where you purchased your
boiler.
12. The safety valve outlet must be connected to the
appropriate drain and ventilation system. The manufacturer
disclaims all liability in the event of damage caused by any
intervention to the safety valve.
13. Carefully dispose of all packaging.
14. In case of water leakage, the water supply must be
switched off and the manufacturer needs to be immediately
informed.
15. The operating pressure of the hydraulic system must be
between 1 and 2 bars and therefore must not exceed 3 bars. If
necessary, the pressure may be reset as shown in the
paragraph "Filling the System".
3

16. The Mg-Anode rod inside the enamel coated cylinder
provides corrosion resistance. Check the Mg-Anode rod every
three years and replace it if necessary.
17. The domestic water network pressure can be up to 6 bar. If
the mains pressure exceeds 6 bar, water is automatically
discharged from the safety valve. If the mains pressure is
above 6 bar, a pressure reducer must be installed at the device
or incoming water supply.
18. The anti-Legionella function increases the Cylinders
temperature to 65 °C once a day to provide hygienic water.
19. If the boiler is not going to be used for a long time, it is
recommended to perform the following steps:
•Turn off the power switch
•Drain the water in both the heating and hot water circuits,
and close off the taps to prevent freezing.
20. The boiler should not be used by children without
supervision.
21.In case of a smoke or burn smell originating from the
device, turn off the power switch and contact the manufacturer.
22. Do not touch the device with wet hands or when the
outside of the device is wet.
23.Do not use chemicals such as detergents or thinners for
cleaning the boiler. Turn off power to the appliance, and then
clean the exterior of the appliance with a slightly damp cloth.
24. The first time you turn on the hot water tap, the water
coming out may be of a very high temperature. Please take
care and check the water temperature.
4

1.Adjust the indoor temperature settings to your needs.
2. Having the heating operation set according to your intended use
will increase energy savings.
3. Savings can be made by adjusting the required temperature
value for each section (of the property with thermostatic
radiator valves), However, simultaneous use of a room
thermostat and thermostatic valves may cause problems.
4. It is important to position the room thermostat away from
objects, such as curtains, articles, etc., which could disrupt the
ambient airflow.. This will ensure that the device can correctly
detect the temperature.
5. The room thermostat should be located at a suitable height
and away from the Boiler and other devices that would affect
detection of the actual ambient temperature.
6. Long-term ventilation of the heated environments will
increases energy loss. Short-term ventilation should be
provided. If long-term ventilation is required, closing the
radiator valves or reducing the device temperature setting
saves energy.
7. Setting the boiler to a lower temperature overnight or when
not at home will save energy while maintaining the ambient
temperature.
8. Setting the operating temperature of the device according to
the outside temperature saves energy.
9. Setting domestic water temperature to a moderate level
saves energy.
2. RECOMMENDATIONS FOR ECONOMICAL USE
5

Your device has a 50 litre integrated enamelled cylinder. From
start up to 65º C DHW will take 10 minutes. During the use of
DHW the cylinder continuous heating, providing continuous hot
water even at very low water pressure and flows.
3. CONFIGURATION OF YOUR DEVICE
4. TECHNICAL INFORMATION
6

Technical Specifications
Model
Power (kW)
Weight
Without
Water (Kg)
Boiler
Volume (l)
3~400 V 50 Hz Electrical Boiler With Cylinder
UKDAX-10EBT
10
50
50
UKDAX-12EBT
12
50
UKDAX-16EBT
16
52
UKDAX-18EBT
18
52
UKDAX-20EBT
20
52
UKDAX-24EBT
24
52
1~220 V 50 Hz Electrical Boiler With Cylinder
UKDAX-6EDM
6
50
50
UKDAX-10EDM
10
50
UKDAX-12EDM
12
50
UKDAX-16EDM
16
52
UKDAX-18EDM
18
52
Technical Specifications
Heating
Tap Water
Min. Operation
Pressure
bar
1
-
Max Operation
Pressure
bar
3
6
Min. Setting
Temperature
oC
35
30
Max. Setting
Temperature
oC
80
65
Connections
inc
h
3/4
1/2
Dimensions
m
m
770*560*390
7

The boiler must be installed by a qualified technician.
5. BOILER ASSEMBLY
5.1 Installation requirements and safety instructions
8

For ease of maintenance, observe the minimum distances
specified in the installation in order to access the boiler.
For correct device positioning:
•Do not place above a stove hob or similar cooking
appliances.
•Do not leave flammable products in the room where the
boiler is installed
•Heat-sensitive walls (eg wooden walls) need proper
insulation. Insulation must be installed between the wall and
boiler.
• Before installation, carefully flush all system piping to remove
any debris that may interfere with the operation of the boiler. In
case of leakage due to overpressure of the heating system,
place a water collection funnel with a suitable drain pipe under
the safety valve. There is no need for a safety valve in the
9

mains hot water circuit, but make sure that the water system
does not exceed 6 bars. If in doubt, have a pressure reducer
installed.
•The area where the boiler is installed must be free of
obstructions and protrusions during repair or maintenance.
•The electrical connection of the boiler must be made with
suitable cables, MCB/RCD and grounding must be installed.
• The wall on which your device is mounted must be strong enough
to bear the weight of the device.
The appliance must be installed exclusively on a vertical and solid
wall that can support the weight of the boiler. M8 screws with
appropriate anchors conforming to the type of the wall itself are
recommended.
Pipe of appropriate diameter to ensure adequate circulation of
the heating water must be used during installation. If the
correct diameter heating pipes are not used, constriction or
blockages in the installation may result in insufficient heating
circulation. Connections to the boiler should be easily
detachable if necessary. Non return Valves should be used
with the inlet pipes. Separate shut-off valves should be used at
the inlet and outlet of the heating circuit. A reducer valve
should be used at the boiler cold water inlet.
5.2. Wall Mounting of the Boiler
5.2.1. Heating and Plumbing Connections
10
Otros manuales para UKDAX-10EBT
2
Este manual sirve para los siguientes modelos
10
Tabla de contenidos
Otros manuales de Caldera de DAXOM

DAXOM
DAXOM THERMOCAR 16B Manual de usuario

DAXOM
DAXOM Naviels Manual de usuario

DAXOM
DAXOM Naviels Manual de funcionamiento

DAXOM
DAXOM Naviels UKDAX-10EDT Manual de usuario

DAXOM
DAXOM Naviels UKDAX-10EDT Manual de usuario

DAXOM
DAXOM UKDAX-80Y10BT Manual de usuario

DAXOM
DAXOM Navidens 50 Manual de usuario

DAXOM
DAXOM Thermotank UKDAX-160GB25 Manual de usuario