Datamars Unigizer 1 J Manual de usuario

1
1, 2, 3 J MkII Unigizer™
USER GUIDE
© 2006-2020 Datamars Limited.
All product names and brand names in this document are trademarks or registered trademarks of their respective holders.
No part of this publication may be photocopied, reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise without the prior written permission of Datamars Limited. Product specifications may change without prior notice.
For more information on other quality Datamars brands and products, visit datamars.com
Datamars Limited
25 Carbine Road
Mt Wellington
Auckland 1060
New Zealand
Postal address:
P O Box 51
078
Pakuranga
Auckland 2140
New Zealand
(EN) EU Importer:
(ES) Importador de la UE:
(PT) Importador da UE:
(FR) Importateur UE :
(DE) EU
-Importeur:
(SV) EU
-importör:
(NL) EU
-importeur:
(DA) EU
-importør:
Datamars Slovakia s.r.o.
Dolné Hony 6, 949 01 Nit
ra,
Slovak Republic
Datamars Ltd thanks the International Electrotechnical Commission (IEC) for permission to reproduce Information from its International Publication 60335-2-76 ed.2.2 (2013). All such extracts
are copyright of IEC, Geneva, Switzerland. All rights reserved. Further information on the IEC is available from www.iec.ch. IEC has no responsibility for the placement and context in which the
extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.
480 0000-798 Issue 4 05/2020

2
Contents
Safety Information (EN) 3
Información de seguridad (ES) 11
Informações de segurança (PT) 19
Consignes de sécurité (FR) 27
Sicherheitsinformationen (DE) 36
Säkerhetsinformation (SV) 44
Veiligheidsinformatie (NL) 51
Sikkerhedsinformation (DA) 60
Installing the energizer (EN) 68
Instalación del energizador (ES) 79
Instalação do energizador (PT) 88
Installation de l'électrificateur (FR) 96
Weidezaungerät installieren (DE) 105
Installera aggregatet (SV) 113
Elektro-afrasteringsapparaat installeren (NL) 121
Installation af spændingsgiveren (DA) 129

3
ENGLISH
Safety information
WARNING: READ ALL INSTRUCTIONS
Note:
This product has been designed for use with electric animal fences.
General warnings
WARNING!
-This energizer is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
energizer by a person responsible for their safety.
-Children should be supervised to ensure that they do not play with the energizer.
Cleaning and user maintenance shall not be made by children without supervision.
-Disconnect the energizer before installation or performing any work on the fence.
-Risk of electric shock! This energizer should be opened or repaired only by
qualified personnel.
Warnings specific to this energizer
Warning!
-
USA and Canada
- To reduce the risk of electric shock, the energizer's power
adaptor may have a polarized plug (one blade is wider than the other). This plug
will fit in a polarized outlet one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install the
proper outlet. Do not change the plug in any way.
-Check your installation to ensure that it complies with all local safety regulations.

4
-Do not connect simultaneously to a fence and to any other device such as a cattle
trainer or a poultry trainer. Otherwise, lightning striking your fence will be
conducted to all other devices.
-Use only the mains/line power adaptor or battery leads supplied with this
energizer or a genuine replacement part.
-The power input socket on the back of the energizer is for 12 V DC only.
-
Europe
- The energizer must be located in a shelter, and the cable must not be
handled when the temperature is below 5 °C.
Important safety instructions for Class 2 power
units (USA/Canada only)
When using electrical products, basic precautions should always be practiced including
the following:
1READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2Read and follow all instructions that are on the product or provided with the
product.
3Do not use an extension cord.
4Reference the National Electrical Code, ANSI/NFPA 70, specifically for the
installation of wiring and clearances from power and lighting conductors.
5Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated
construction.
6Do not install or use within 3 m (10') of a pool.
7Do not use in a bathroom.

5
8WARNING: Risk of Electric Shock. When used outdoors, install only to a covered
Class A GFCI protected receptacle that is weatherproof with the power adaptor
connected to the receptacle. If one is not provided, contact a qualified electrician
for proper installation. Ensure that the power adaptor and cord do not interfere
with completely closing the receptacle cover.
9WARNING: Risk of Fire. Installation involves special wiring methods to run wiring
through a building structure. Consult a qualified electrician.
10 WARNING: Risk of Electric Shock. Mount the unit at a height greater than 30 cm
(1') from the ground surface.
11 SAVE THESE INSTRUCTIONS – This manual contains important safety and
operating instructions for power adaptors.
Important safety instructions for power adaptors
(all other countries)
DANGER! RISK OF ELECTRIC SHOCK. INDOOR LOCATIONS ONLY.

6
Key to symbols on the energizer
Fence earth terminal. Connect the fence earth terminal to the energizer
earth system.
Fence output terminal. Connect the fence output terminal to the fence.
Risk of electric shock! This energizer should be opened or repaired only by
qualified personnel.
Read full instructions before use.
This symbol on the product or its packaging indicates that this product
must not be disposed of with other waste. Instead, it is your responsibility
to dispose of your waste equipment by handing it over to a designated
collection point for the recycling of waste electrical and electronic
equipment. The separate collection and recycling of your waste equipment
at the time of disposal will help conserve natural resources and ensure
that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your
waste equipment for recycling, please contact your local city recycling
office or the dealer from whom you purchased the product.
Energizers marked with this symbol are time delayed electric fence
energizers with a delay time of 20 seconds.
Only use with a Datamars Ltd approved power adaptor. This must be
either the power adaptor provided with the energizer or a genuine
replacement part supplied by Datamars (see details marked on the
energizer, beside the power inlet).

7
Definition of special terms
Energizer
– An appliance that is intended to periodically deliver voltage impulses to a
fence connected to it.
Fence
– A barrier for animals or for the purpose of security, comprising one or more
conductors such as metal wires, rods or rails.
Electric fence
– A barrier which includes one or more electric conductors, insulated
from earth, to which electric pulses are applied by an energizer.
Fence circuit
– All conductive parts or components within an energizer that are
connected or are intended to be connected, galvanically, to the output terminals.
Earth electrode
– Metal structure that is driven into the ground near an energizer and
connected electrically to the fence earth terminal of the energizer, and that is
independent of other earthing arrangements.
Connecting lead
– An electric conductor, used to connect the energizer to the electric
fence or the earth electrode.
Electric animal fence
– An electric fence used to contain animals within or exclude
animals from a particular area.
Requirements for electric animal fences
In accordance with Annex BB Section BB.1 of IEC 60335-2-76
Electric animal fences and their ancillary equipment shall be installed, operated and
maintained in a manner that minimises danger to persons, animals or their
surroundings.
Electric animal fence constructions that are likely to lead to the entanglement of
animals or persons shall be avoided.

8
WARNING!
Avoid contacting electric fence wires especially with the head, neck or
torso. Do not climb over, through or under a multi-wire electric fence. Use a gate or
a specially designed crossing point.
An electric animal fence shall not be supplied from two separate energizers or from
independent fence circuits of the same energizer.
For any two separate electric animal fences, each supplied from a separate energizer
independently timed, the distance between the wires of the two electric animal fences
shall be at least 2.5 m (8'). If this gap is to be closed, this shall be effected by means
of electrically non-conductive material or an isolated metal barrier.
Barbed wire or razor wire shall not be electrified by an energizer.
A non-electrified fence incorporating barbed wire or razor wire may be used to support
one or more off-set electrified wires of an electric animal fence. The supporting devices
for the electrified wires shall be constructed so as to ensure that these wires are
positioned at a minimum distance of 150 mm (6") from the vertical plane of the non-
electrified wires. The barbed wire and razor wire shall be earthed at regular intervals.
Follow our recommendations regarding earthing.
A distance of at least 10 m (33') shall be maintained between the energizer earth
electrode and any other earthing system connected parts such as the power supply
system protective earth or the telecommunication system earth.
Connecting leads that are run inside buildings shall be effectively insulated from the
earthed structural parts of the building. This may be achieved by using insulated high
voltage cable.
Connecting leads that are run underground shall be run in conduit of insulating
material or else insulated high voltage cable shall be used. Care must be taken to
avoid damage to the connecting leads due to the effects of animal hooves or vehicle
wheels sinking into the ground.

9
Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.
Connecting leads and electric animal fence wires shall not cross above overhead
power or communication lines.
Crossings with overhead power lines shall be avoided wherever possible. If such a
crossing cannot be avoided it shall be made underneath the power line and as nearly
as possible at right angles to it.
If connecting leads and electric animal fence wires are installed near an overhead
power line, the clearances shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line voltage
Clearance
≤1000 V 3 m (10')
>1000 V to ≤33,000 V 4 m (13')
>33,000 V 8 m (27')
If connecting leads and electric animal fence wires are installed near an overhead
power line, their height above the ground shall not exceed 3 m (10'). This height
applies to either side of the orthogonal projection of the outermost conductors of the
power line on the ground surface, for a distance of:
•2 m (6'6") for power lines operating at a nominal voltage not exceeding 1000 V.
•15 m (50') for power lines operating at a nominal voltage exceeding 1000 V.
Electric animal fences intended for deterring birds, household pet containment or
training animals such as cows need only be supplied from low output energizers to
obtain satisfactory and safe performance.
In electric animal fences intended for deterring birds from roosting on buildings, no
electric fence wire shall be connected to the energizer earth electrode. A warning sign
shall be fitted to every point where persons may gain ready access to the conductors.

10
Where an electric animal fence crosses a public pathway, a non-electrified gate shall
be incorporated in the electric animal fence at that point or a crossing by means of
stiles shall be provided. At any such crossing, the adjacent electrified wires shall carry
warning signs.
Any part of an electric animal fence that is installed along a public road or pathway
shall be identified at frequent intervals by warning signs securely fastened to the fence
posts or firmly clamped to the fence wires.
•The size of the warning sign shall be at least 100x200 mm (4x8").
•The background colour of both sides of the warning sign shall be yellow. The
inscription on the sign shall be black and shall be either:
or the substance of "CAUTION: Electric fence".
•The inscription shall be indelible, inscribed on both sides of the warning sign and
have a height of at least 25 mm (1").
Ensure that all mains-operated, ancillary equipment connected to the electric animal
fence circuit provides a degree of isolation between the fence circuit and the supply
mains equivalent to that provided by the energizer.
Protection from the weather shall be provided for the ancillary equipment unless this
equipment is certified by the manufacturer as being suitable for use outdoors, and is of
a type with a minimum degree of protection IPX4.
Este manual sirve para los siguientes modelos
5
Tabla de contenidos
Idiomas:
Otros manuales de Fuente de alimentación de Datamars

Datamars
Datamars 0.5 J MkII Unigizer Manual de usuario

Datamars
Datamars Unigizer 6 J Manual de usuario

Datamars
Datamars Patriot PMX50 Manual de usuario

Datamars
Datamars Unigizer 6 J Manual de usuario

Datamars
Datamars Patriot PMX350 Manual de usuario

Datamars
Datamars B500 Manual de usuario

Datamars
Datamars UNIGIZER 15J Manual de usuario