Dataman S6 Manual de usuario

Dataman-S6 - User's Manual
Dataman-S6
Compact USB Programmer
User's Manual
StockCheck.com

Dataman-S6 - User's Manual
Contents
Chapter 1 Product Description
1-1 Introduction
1-2 Safety Information
1-3 Precautions
1- Operating System, Hardware Requirements
1-5 Accessories
Chapter 2 Product Installation
2-1 Hardware Installation
2-2 Software Installation
2-3 Driver Installation
Chapter 3 IC Insertion
3-1 General IC Insertion (DIP package)
3-2 Special IC Insertion via Adapter (Special package)
Chapter Software Operation
-1 Main Screen
-1-1 IC Information Column
-1-2 Message Window
-1-3 Programming Result Statistics
-1- Other Operation Buttons
-2 Device Select/Project
-2-1 Device Select
-2-2 Device Type
-2-3 Device Search
-2- Device Search Operators
-2-5 Device Search Results
-2-6 Selected Device History
-3 File Load
-3-1 Load File Path
-3-2 File Format
-3-3 Source Select
-3- Destination Select
-3-5 “Fill Unused With” Function
- Edit
- -1 Display Mode (8 Bits/16 Bits)
- -2 View/Edit Mode
-5 Option Settings
-5-1 General System Settings
-5-2 Insertion Detection
-5-3 Device ID Check
StockCheck.com

Dataman-S6 - User's Manual
-5- Confirm Error List
-5-5 Programming Area Selection
-5-6 Message Column Settings
-5-7 Self-Test Function
-5-8 Device Options
-6 Save
-6-1 Save File Path and Name
-6-2 Save File Format
-6-3 Buffer Range for Saving
-7 Device Processing Procedure
-7-1 Read
-7-2 Data Confirm
-7-3 Erase
-7- Blank Check
-7-5 Program
-7-6 Verify
-7-7 Protect
-7-8 RUN ALL
-7-9 Description of Actions
Chapter 5 Basic Operation Examples
5-1 Programming an MCU from user data located on the computer and
protecting the IC
5-2 Reading the internal memory of an IC and saving the data out in Binary
format
5-3 Using the system's Self Test function to detect and test the programmers
hardware
Chapter 6 Troubleshooting
Chapter 7 Glossary of Terms
StockCheck.com

Dataman-S6 - User's Manual
Chapter 1 Product Description
1-1 Introduction
With 30 years experience Dataman is the world’s leading provider of device programmers. We offer
a comprehensive range of programming solutions suitable for every requirement from design and
development to large scale production.
We are committed to providing continued development, manufacturing and support and to deliver
customer specific innovative solutions.
All Dataman products come with comprehensive warranties, free lifetime support and free software
updates via our website and telephone helpdesk.
1-2 Safety Information
All the operations, maintenance and repair services are required to follow the below safety
information. We do not take responsibility for unexpected problems by misusing the equipment.
1. The programmer must be connected to the host computer using the supplied Y type USB
cable. Check that both USB plugs are connected to the computer and confirm that the
available USB power is sufficient to operate the programmer correctly. If the computer is
connected through a USB Hub it will need to be a powered hub (+5V/1A or above).
2. Do not operate the product near flammable gases. High-temperatures and humidity should
also be avoided.
3. Do not remove the product's case to adjust or replace any internal parts.
. Sockets or adapters are considered consumables. The life time is determined from the
frequency of use specified in the manufactures specification. If a socket is used beyond the
rated number of actuations specified by the manufacturer, the socket will start to give errors
caused by poor contact. This will result in an increasing number of contact errors and burn
failures.
5. When using this product as mass production or production for master tape, please take the
appropriate testing precautions before assembling the completed product. All the risks
attributed to using the product or operating the software are undertaken by the user.
6. This manual is for reference and preservation of the consumer. Product specifications and
manuals are subject to change without notice.
7. The company or trademarks mentioned in this manual are the property of their respective
owners.
1-3 Precautions
1. When you work with your IC using our programmer it will access the device using a high
frequency signal. To ensure proper programming and high yield rates you must observe the
following:
a) During any operation with the IC (read / verify / programming / erase / blank check ...
etc) do not touch the IC or ZIF socket. When inserting an IC into the ZIF socket,
please take note of basic electrostatic protection measures.
1
StockCheck.com

Dataman-S6 - User's Manual
b) If you need adapters for other kinds of IC package (for example, TSOP, PLCC, TQFP,
QFN ... etc.) we would advise that you contact Dataman. Do not use inferior quality
adapters or try to create adapters yourself. The Dataman-S6 programmer
communicates with the IC using a high-frequency signal. If external adapters are of
poor quality we will be unable to give any guarantee on the programming results!
2. When connecting the Dataman-S6 programmer to the computer please note:
a) You must use the supplied Y-type USB cable. Check that both USB plugs are
connected to the host computer before connecting the programmer. An ordinary
single USB cable is not suitable as it will not supply enough power to the unit and you
may experience problems with stability during programming.
b) When the Dataman-S6 software is launched and connection to the programmer is
established the programmer will check the USB power supply, if the power supply is
not sufficient a warning message will be displayed. If you are using an external USB
hub its supply may be limited. In which case you would need to use a power adapter
capable of (5V, 1A or greater) to improve it.
On the warning message window you can press the "Retry" button to re-test the
supply once you have made a change. You can also press the "Cancel" button to skip
the power detection. However by doing so the system can not guarantee 100%
correct operation.
1- Operating System, Hardware Requirements
Operating System: Windows XP / Windows Vista / Windows 7
CPU: PC / Pentium IV or above
Memory: 512 MB RAM or above
Hard disk space: 500 MB or more (main program)
1 GB or more (program buffer (depending on
selected device capacity))
Monitor Resolution: 800 x 600 pixels or above
Interface: USB 2.0 High Speed
2
StockCheck.com

Dataman-S6 - User's Manual
Power Requirements: 2 x USB Ports providing +5 V power supply
Dimensions: 130 (L) x 90 (depth) x 20 (high) mm
Note: Height does not include ZIF Socket
Weight: 290g
Operating temperature: +5 to + 5 ℃ ℃
1-5 Accessories
Programmer: 1
Special Y-USB cable: 1
CD-ROM (software and manual): 1
3
StockCheck.com

Dataman-S6 - User's Manual
Chapter 2 Product Installation
2-1 Hardware Installation
1. Use the supplied Y-type USB cable connected two USB ports on the host computer. If you
use an external USB Hub, please connect it to a power adapter rated at (5V,> 1A or above),
and remove any other USB powered devices such as external hard drives...and so on.
2. The blue LED on the Dataman-S6 will not illuminate until the software driver has been
installed. After installing the driver the programmers' LED will flash twice then turn off. When
in operation the LED will be illuminated, when the software is closed down the LED will turn
off.
2-2 Software Installation
1. Please note that when installing the software on your computer, the operating system will
require "administrator" permissions. If you do not have administrator permissions it may
result in an unsuccessful installation.
2. Insert the CD, the installation screen should automatically appear. If there's no installation
screen please install through "My Computer" > CD-ROM drive > and execute the
AUTORUN.EXE
3. Press the "Install" button to start the installation, modify the installation path and name of the
start menu link if required. Finally press the "Finish" button to complete the software
installation.
. Next, click on the database installation files on the CD (or download from
www.dataman.com). This will update the IC database.
2-3 Driver Installation
1. Please install the main software on your computer first and then connect the programmer to
computer using the supplied Y-type USB cable. The driver installation will automatically start.
2. The first time the programmer is connected to the host PC it will display a message about
finding new hardware, and will then ask if you want to go ahead and install the driver. Please
follow these steps to complete the installation.
StockCheck.com

Dataman-S6 - User's Manual
5
Check this item
StockCheck.com

Dataman-S6 - User's Manual
3. The path is set to "C:\Dataman Programmers\USBDrv" (Check the item “Include this location
in the search”.)
. After installation, you will see the the "Dataman-S6” device listed under “Device manager”-
Control Panel \ System \ Hardware \ Device Manager. This shows that the installation was
successful.
6
check this item
Set the driver path
check this item
Choose to continue the installation
StockCheck.com

Dataman-S6 - User's Manual
7
This icon represents successful driver
installation
Press [Finish] To Complete
the installation
StockCheck.com
Tabla de contenidos
Otros manuales de Placa madre de Dataman

Dataman
Dataman DATAMAN-448PRO2 Manual de usuario

Dataman
Dataman S4 Manual de usuario

Dataman
Dataman 448PRO2 Manual de usuario

Dataman
Dataman DATAMAN-848PRO2 Manual de usuario

Dataman
Dataman DATAMAN-848PRO2 Manual de usuario

Dataman
Dataman 448PRO2AP-AU Manual de usuario

Dataman
Dataman 48UXP Manual de usuario

Dataman
Dataman 448PRO2AP Manual de usuario
Manuales populares de Placa madre de otras marcas

Telit Wireless Solutions
Telit Wireless Solutions SL869-3DR Manual de usuario

Gigabyte
Gigabyte GA-9IVDT Manual de usuario

Texas Instruments
Texas Instruments ADS8372EVM Manual de usuario

Commell
Commell MS-C73 Manual de usuario

IBT Technologies
IBT Technologies MB860 Manual de usuario

Nvidia
Nvidia TEGRA DG-04927-001_V01 Manual de usuario