DART SYSTEMS MINI DARTEYE Manual de usuario

1
MINI DARTEYE –USER GUIDE
CONTENTS
Introduction
Mini DartEye Controls
Monitor Controls, Battery Meter
Light Operation, Sonde Operation
Distance Counter, Screen Titler
Wi-Fi
Wi-Fi App Note
Battery Charging/Recharging
Specifications
DS100 Initial Setup
DVR System Settings
Set Time Date menu
Manual Capture menu
Auto Capture menu
Motion Detect menu
Advanced Setting menu
Using the Display controls
Using the DVR Controls
Screen Icons
Keypad Controls
Still Image Capture
Manual Record and Playback
Charging the Batteries
Powering the system from AC adapter
Quick Tips
Specifications
Notes
2
3
6
6
7
8
9
10
11
12
14
17
18
20
21
21
22
23

2
MINI DARTEYE –USER GUIDE
INTRODUCTION
DartEye Mini Variants
Variant Part No Description
1 565-900 Mini DartEye 30 Mtr Standard Unit
2 565-901 Mini DartEye 30 Mtr Sonde & Meter Counter
3 565-902 Mini DartEye 30 Mtr Sonde, Meter Counter, Text
Editor & Wi-Fi
SAFETY WARNINGS
The system is not earthed. If mains operated equipment is connected to the system
then the external equipment must be earthed.
Do not use the Mini DartEye system in potentially explosive environments. This
equipment is not approved for use in hazardous environments.
Foul water can be a source of biological hazards. Wear appropriate protection at all
times.
The camera head will get hot during use, this is normal. Take care when handling
the camera at all times.

3
MINI DARTEYE –USER GUIDE
MINI DARTEYE CONTROLS
1. On / Off Switch
2. Monitor Controls
3. Recording Controls
4. Battery Charge Socket
5. 12v Adapter Socket
6. SD Card Slot
7. Battery Status Indictor
8. Light Control
9. Meter Counter Controls (Variant 2 & 3)
10. Video out Socket
11. Keyboard Socket (Variant 3) –Provides 10 pages of saveable text
plus shortcuts
12. 33Khz Sonde Switch (Variant 2 & 3) Switches Sonde off / on
13. Camera Connection Socket
2
3

4
MINI DARTEYE –USER GUIDE
13
5
4
1
6
9
8
7
12
Fig 2
Fig 1

5
MINI DARTEYE –USER GUIDE
11
10
Fig 3

6
MINI DARTEYE –USER GUIDE
MONITOR CONTROLS
Switch on
Turn the system on using the power
switch located at (fig 1 (1)).
The splash panel displays DartEye
Mini –No keyboard.
If version 3 unit then screen will
display DartEye Mini –keyboard
when turned on if the keyboard is
connected.
The total length of cable fitted to the
unit is displayed momentarily in the
bottom right of the screen.
Battery Meter
Check the battery level by pressing
and holding button (fig 2(7)) on the
Hub Control Panel, each
illuminated segment represents
20% battery life remaining.
Brake
Release the brake to allow the
camera and cable to be used by
lifting and turning the spring
plunger. To engage the brake turn
the spring plunger and the plunger
will drop into the next hole on the
reel hub.
Skids
The 50mm Skid provided with the
system is for use in pipes from
50mm to 100mm. The Camera can
be used without the skid fitted if
pipes under 50mm diameter are to
be inspected.
Monitor Removal
To remove the monitor from the
frame, loosen the two star knobs on
the reverse of the monitor and slide
the monitor up. The monitor can
then be used remotely. To store the
monitor in the transit case (optional)
unscrew the collar from the
connection cable and then pull to
release.
Connection is the reverse of this
operation.
When refitting the monitor to the
frame the cable should be routed
through the central slot in the
monitor mount plate.
LIGHT OPERATION
The Mini DartEye Camera head
has six high output LED’s. Use the
control knob on the Hub Control
Panel to vary the intensity of the
LED’s depending on working
conditions.

7
MINI DARTEYE –USER GUIDE
Sonde 33 KHz (Variant 2
& 3)
The unit is fitted with a high output
Sonde Transmitter which operates
at a frequency of 33KHz. The
Sonde is locatable by a standard
Camera / Cable locator with a
depth function.
To turn the Sonde on press the
Sonde Button (fig 2 (12)). A green
LED illuminates signifying that the
Sonde is working.
Due to the high output of the
transmitter the image is turned off
whilst the sonde is turned on, due
to interference caused by the high
signal strength.
DISTANCE COUNTER
(Variant 2 & 3)
The on screen distance counter
provides an estimate of how much
rod has been deployed, which can
be used to establish the position of
the camera head. The counter
should be calibrated before cable
deployment. The cable count can
be reset to zero at any time to give
a relative distance count, by
pressing F12.
Before each operation the system
should be calibrated with the
Camera Head in the Rod guide and
the entire rod stored in the reel and
pressing F11 on the keyboard.
When starting a survey the counter
can be zeroed by pressing F12.
Screen Titler Controls
(Variant 3)
NOTE –When the keyboard is
plugged in control of the meter
counter switches to the keyboard
from the Hub Plate. When the
keyboard is disconnected
control of the meter counter
switches back to the Hub Plate.
F1-F10 -Text Pages, loads a text
page, or toggles it off.
F11 -'CAL' function. Zero’s the
absolute count, and the relative
offset. It should only be used with
the entire rod on the reel.
F12 -'Zero' function. Updates the
distance offset so that the
displayed relative meterage will
read zero at this point.
Control-C -Clears the text display
and the current page from the
memory.
To move around the screen use the
arrow keys (up, down, left, right)
and the backspace / delete keys.
Control-M -Cycles meterage mode,
from metric, to imperial, to off, and
back to metric.

8
MINI DARTEYE –USER GUIDE
Control-D -Types the diameter
symbol.
Control-K -Types the degrees
symbol.
Control-E -Types the euro symbol.
Please ensure that the keyboard is
plugged in and disconnected whilst
camera is powered off. If the
keyboard isn’t functioning correctly
turn the camera off and back on
again.
Wi-Fi (Variant 3)
Go to the google play store or APP
store and search for “WIFIAV-
HD” and install the APP (see
logo for relevant APP) on the
device.
The icon should now appear on
your device.
Go to the Wi-Fi settings on your
device and select WIFIAV (Default
password: 12345678).
To view images remotely select the
APP on your device. Only one
device can be linked to the live view
at a time.
Controls
1 Press to record video, red
clock logo will appear in the
top left when view is being
recorded
2 Not Used
3 Press to save still image
4 Press to view recorded
video files
5 Press to view still images
6 Settings allows the
password to be changed
Zoom in and zoom out function can
be used if the mobile device allows.
1 2 3 4 5 6

9
MINI DARTEYE –USER GUIDE
Wi-Fi APP NOTE
The WIFI module in the DS100 is
by DEFAULT set for use with
iPhone SSID:WIFIAV (this is the
name of the WiFi connection as
seen on the mobile device).
If required the mode can be
changed to operate with any
ANDROID handset by following the
instructions below:
The DS100 monitor should be
powered on during this process.
On the back of the DS100 to the
right hand side of the product label
is a small hole. Using a pin, or
similar instrument, press the
internal switch 4 times to ENABLE
SSID:WIFIAV-SAMSUNG (this is
the name of the WiFi connection as
seen on the mobile device).
Check your mobile device to see
that WIFIAV-SAMSUNG is
available.
To return to iPhone press the
internal switch and hold for a
minimum of 10 secs.
Check your mobile device to see
that WIFIAV is available.
IT IS RECOMMENDED THAT THE
RESET HOLE BE COVERED
USING ONE OF THE LABELS
SUPPLIED TO PREVENT
MOISTURE AND DUST INGRESS.
Wifi reset switch
Tabla de contenidos
Otros manuales de Instrumento analítico de DART SYSTEMS
Manuales populares de Instrumento analítico de otras marcas

EXTOL PREMIUM
EXTOL PREMIUM 8820043 Instrucciones de instalación y funcionamiento

RIDGID
RIDGID SeeSnake Compact Manual de usuario

Teledyne
Teledyne 3000PA Manual de usuario

YDLIDAR
YDLIDAR TIA Manual de usuario

Olympus
Olympus IPLEX FX Series Manual de usuario

Bosch
Bosch GLM 50 C Professional Manual de usuario