Danfoss VLT AAF006 Manual de usuario

At the end of this document you will find links to products related to this catalog. You can go directly to our shop by
clicking HERE. HERE

MAKING MODERN LIVING POSSIBLE
Operating Instructions
VLT® Active Filter AAF006
www.danfoss.com/drives


Contents
1 Introduction 4
1.1 Purpose of the Manual 4
1.2 Additional Resources 4
1.3 Product Overview 4
1.3.1 Working Principle 4
1.3.2 IEEE519 Compliance 5
1.4 Ordering Information 6
1.4.1 Filter Configurator 6
1.4.2 Ordering Form Type Code 6
2 Safety 7
2.1 Safety Symbols 7
2.2 Qualified Personnel 7
2.3 Safety Precautions 7
3 Mechanical Installation 8
3.1 Pre-installation 8
3.1.1 Planning the Installation Site 8
3.1.2 Receiving the Active Filter 8
3.1.3 Transportation and Unpacking 8
3.1.4 Lifting 8
3.1.5 Mechanical Dimensions 9
3.2 Mechanical Installation 11
3.2.1 Tools Needed 11
3.2.2 Clearance Requirements 11
3.2.3 Power Terminal Locations 12
3.2.4 Cooling and Airflow 13
3.2.5 Gland/Conduit Entry - IP21 (NEMA 1) and IP54 (NEMA12) 14
4 Electrical Installation 15
4.1 Safety Instructions 15
4.2 Electrical Installation 15
4.2.1 Power Connections 15
4.2.2 Grounding 16
4.2.3 EMC Interference 17
4.2.4 Extra Protection (RCD) 18
4.2.5 RFI Switch 18
4.2.6 Torque 18
4.2.7 Current Transformer (CT) 18
4.2.8 Auto CT Detection 22
Contents Operating Instructions
MG90V302 Danfoss A/S © 09/2014 All rights reserved. 1

4.2.9 Summation Transformers 23
4.2.10 Operating with Capacitor Banks 24
4.2.11 Fuses 26
4.2.12 Mains Disconnectors 26
4.2.13 Control and CT Cable Routing 26
4.2.14 Control Wire Installation 26
4.2.15 Unscreened Control Wires 27
4.2.16 Electrical Installation, Control Cables 28
4.3 Installation Checklist 29
5 User Interface 30
5.1 Local Control Panel Operation 30
5.1.1 Modes of Operation 30
5.1.2 How to Operate Graphical LCP (GLCP) 30
5.1.3 Changing Data 33
5.1.4 Changing a Text Value 33
5.1.5 Changing a Group of Numeric Data Values 33
5.1.6 Changing of Data Value, Step-by-Step 33
5.1.7 Readout and Programming of Indexed Parameters 33
5.1.8 Quick Transfer of Parameter Settings with the LCP 34
5.1.9 Initialisation to Default Settings 34
5.1.10 RS485 Bus Connection 35
5.1.11 Connection to a PC 35
6 Applications and Basic Programming 36
6.1 Paralleling of Active Filters 36
6.2 Programming 38
6.3 Description of Parameters 41
6.4 0-** Operation/Display 41
6.5 5-** Digital I/O Mode 46
6.6 8-** General Settings 48
6.7 14-2* Trip Reset 50
6.8 15-** Drive Information 52
6.9 16-** Data Readouts 56
6.10 300-** AF Settings 58
6.11 301-** AF Readouts 61
6.12 Parameter Lists 62
6.12.1 Default Settings 62
6.12.2 0-** Operation/Display 63
6.12.3 5-** Digital In/Out 64
6.12.4 8-** Comm. and Options 64
Contents Operating Instructions
2 Danfoss A/S © 09/2014 All rights reserved. MG90V302

6.12.5 14-** Special Functions 65
6.12.6 15-** FC Information 65
6.12.7 16-** Data Readouts 67
6.12.8 300-** AF Settings 68
6.12.9 301-** AF Readouts 68
7 RS485 Installation and Set-up 69
7.1 Installation and Set-up 69
7.2 Network Configuration 70
7.3 FC Protocol Message Framing Structure 70
7.3.12 Conversion 73
7.4 How to Access Parameters in Modbus RTU 74
8 Maintenance, Diagnostics and Troubleshooting 75
8.1 Maintenance and Service 75
8.2 Warning and Alarm Types 75
8.3 Active Filter Warning and Alarm Definitions 76
9 Specifications 81
9.1 Power Rating 81
9.2 Derating for Altitude and Ambient Temperature 84
9.3 Acoustic Noise 84
10 Appendix 85
10.1 Abbreviations and Conventions 85
Index 86
Contents Operating Instructions
MG90V302 Danfoss A/S © 09/2014 All rights reserved. 3

1 Introduction
1.1 Purpose of the Manual
These operating instructions provide information for safe
installation and commissioning of the filter.
The operating instructions are intended for use by
qualified personnel.
Read and follow the operating instructions to use the filter
properly, and pay particular attention to the safety
instructions and general warnings. Keep these operating
instructions available with the filter at all times.
VLT®is a registered trademark.
1.2 Additional Resources
Resources available to understand advanced active filter
functions and programming:
•The VLT
®
Advanced Active Filter Service Manual
provides information on troubleshooting and
testing for field service technicians, as well as
disassembly and assembly instructions.
1.3 Product Overview
1.3.1 Working Principle
The VLT®Advanced Active Filter is used for harmonic
current mitigation and reactive current compensation. The
unit can integrate with various systems and applications as
a centrally installed filter or be combined with a VLT®
frequency converter as a packaged low harmonic drive
solution.
M
M M
130BB717.10
Illustration 1.1 Multiple Working Environments
The active shunt filter monitors all 3-phase line currents
and processes the measured current signal via a digital
signal processor system. The filter then compensates by
actively imposing signals in counter phase to the
unwanted elements of the current (harmonic distortion).
130BB718.10
Illustration 1.2 Active Filter Principles
The filter sets different IGBT switches in real time feeding a
DC voltage into the grid, which creates counter phase
signals. A built-in LCL filter smooths the compensated
current waveform, ensuring that the IGBT switching
frequency and DC component is not imposed to the grid.
The filter operates on generator or transformer supply and
can reduce individual motor loads, non-linear loads, or
Introduction Operating Instructions
4 Danfoss A/S © 09/2014 All rights reserved. MG90V302
1
1

mixed loads. Non-linear loads (diode feed loads) must hold
AC coils to protect against overcurrent of the input diodes.
Control Manual
Disconnect
Fuse
Option
Soft charge
circuit
130BB719.10
Illustration 1.3 Block Diagram
The filter allows either overall or selective harmonic
compensation modes. In overall compensation mode, all
harmonics are reduced. In this mode, the filter balances
the load to reduce uneven load distribution among the 3
phases. The steady state performance allows compensation
of harmonics to the 40th order, but the ultra-quick current
injection allows the filter to compensate flicker and other
quick and short-term phenomena. In selective mode, the
user can program acceptable individual harmonic levels
between 5th and 25th order. In selective mode, the filter
does not reduce harmonics in twos and threes, and does
not support phase load balancing and flicker reduction.
See parameter 300-00 Harmonic Cancellation Mode.
Program the filter priority as either reactive current or
harmonic compensation. If harmonic compensation is first
priority, the filter uses the current needed for harmonic
reduction and uses energy for reactive current correction
only if there is excess. The filter automatically and contin-
uously assigns energy between first and second priority to
provide the highest possible mitigation of both reactive
and harmonic compensation. The power factor is
optimised continuously and the supply transformer is used
to its maximum capacity. See parameter 300-01 Compen-
sation Priority.
The active filter has an optional RFI filter for Class A1 equal
to category C2.
1.3.2 IEEE519 Compliance
The active filter is designed to meet IEEE519 recommen-
dation for Isc/Il >20 for even individual harmonic levels.
The filter has a progressive switching frequency that
creates a wide frequency spread, giving lower individual
harmonic levels above the 50th harmonic level.
Introduction Operating Instructions
MG90V302 Danfoss A/S © 09/2014 All rights reserved. 5
11

1.4 Ordering Information
1.4.1 Filter Configurator
Use the ordering number system to design an active filter according to the application requirements. For the VLT
®
Active
Filter AAF 006 Series, it is possible to order standard filters and filters with integral options by sending a type code string
describing the product to the local Danfoss sales office. For example: AAF006A190T4E21HXXGCXXXSXXXXAXBXCFXXXDX
This section describes each character in the type code. In the example, a standard 190 A active filter in an enclosure with
IP21 protection rating is selected for a 380–480 V net. The internet-based configurator configures the right filter for the right
application and generates a type code string. The configurator automatically generates an 8-digit sales number to be
delivered to the local sales office. It is also possible to establish a project list with several products and send it to a Danfoss
sales representative. The configurator can be found at www.danfoss.com/BusinessAreas/DrivesSolutions/.
1.4.2 Ordering Form Type Code
130BB504.10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
A FA x0 0 A T 4 E H x G C x x x x x x x B x C x x x x xDAS
Illustration 1.4 Type Code Example
Possible choice
Product groups 1-3 AAF
Series 4-6 006
Current rating 7-10 A190: 190 A
A250: 250 A
A310: 310 A
A400: 400 A
Phases 11 T: 3 Phases
Mains Voltage 12 4: 380–480 V AC
Enclosure 13-15 E21: IP21/Nema Type1
E54: IP54/Nema Type 12
E2M: IP21/Nema Type 1 with
mains shield
E5M: IP54/Nema Type 12 with
mains shield
RFI filter 16-17 HX: No RFI filter
H4: RFI filter, Class A1 (optional)
Display (LCP) 19 G: Graphical Local Control Panel
(LCP)
Coating PCB 20 C: Coated PCB
Mains option 21 X: No mains option
3: Mains disconnect and fuse
7: Fuse
Adaptation A 22 Reserved
Adaptation B 23 Reserved
Software release 24-27 Reserved
Software
language
28 Reserved
A options 29-30 AX: No A option
B options 31-32 BX: No B option
C-option configu-
ration
33-37 CFxxx: CO-option occupied with
active filter control card
D options 38-39 DO: 24 V back-up
DX: No options
Table 1.1 Type Code Definitions
176F3535 Backwall cooling kit for D14 (IP54)
176F3537 Backwall cooling kit for E1 (IP54)
Table 1.2 Optional Kits
Introduction Operating Instructions
6 Danfoss A/S © 09/2014 All rights reserved. MG90V302
1
1

2 Safety
2.1 Safety Symbols
The following symbols are used in this document:
WARNING
Indicates a potentially hazardous situation that could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation that could
result in minor or moderate injury. It can also be used to
alert against unsafe practices.
NOTICE
Indicates important information, including situations that
can result in damage to equipment or property.
2.2 Qualified Personnel
Correct and reliable transport, storage, installation,
operation and maintenance are required for the trouble-
free and safe operation of the active filter. Only qualified
personnel are allowed to install or operate this equipment.
Qualified personnel is defined as trained staff, who are
authorised to install, commission, and maintain equipment,
systems and circuits in accordance with pertinent laws and
regulations. Additionally, the personnel must be familiar
with the instructions and safety measures described in this
document.
2.3 Safety Precautions
WARNING
HIGH VOLTAGE
Active filters contain high voltage when connected to AC
mains input. Failure to perform installation, start-up, and
maintenance by qualified personnel can result in death
or serious injury.
WARNING
DISCHARGE TIME
The active filter contains DC-link capacitors, which can
remain charged even when the filter is not powered.
Failure to wait the specified time after power has been
removed before performing service or repair work can
result in death or serious injury.
Voltage
[V]
Output Current
[A]
Minimum waiting
time
(minutes)
380–480 190–400 20
High voltage can be present even when the warning indicator
lights are off.
Table 2.1 Discharge Time
WARNING
LEAKAGE CURRENT HAZARD
Leakage currents exceed 3.5 mA. Failure to ground the
filter properly can result in death or serious injury.
•Ensure correct grounding of the equipment by
a certified electrical installer.
WARNING
EQUIPMENT HAZARD
Contact with rotating shafts and electrical equipment
can result in death or serious injury.
•Ensure that only trained and qualified
personnel perform installation, start up, and
maintenance.
•Ensure that electrical work conforms to national
and local electrical codes.
•Follow the procedures in this document.
CAUTION
INTERNAL FAILURE HAZARD
An internal failure in the filter can result in serious injury
when the filter is not properly closed.
•Before applying power, ensure all safety covers
are in place and securely fastened.
Safety Operating Instructions
MG90V302 Danfoss A/S © 09/2014 All rights reserved. 7
22
Otros manuales para VLT AAF006
1
Tabla de contenidos
Otros manuales de Sistema de filtración de agua de Danfoss

Danfoss
Danfoss VLT AAF00x Manual de usuario

Danfoss
Danfoss VLT AHF005 Guía

Danfoss
Danfoss AAF 007 Manual de instalación y funcionamiento

Danfoss
Danfoss AHF 005 Manual de usuario

Danfoss
Danfoss VLT AAF00x Manual de usuario

Danfoss
Danfoss VLT AHF 005 Manual de usuario

Danfoss
Danfoss VLT AHF 005 Manual de usuario

Danfoss
Danfoss AHF 005 Manual de usuario

Danfoss
Danfoss AHF 010 Guía

Danfoss
Danfoss IPS 8 Manual de usuario






















