D-AIR DA-08P Manual de usuario

DA-08P
DA-12P

1
CONTENTS
CONTENTS...................................................................................................................1
IMPORTANT SAFEGUARDS.................................................................................2
FEATURES AND PARTS LIST..............................................................................4
PANEL CONTROL......................................................................................................5
REMOTE CONTROL................................................................................................. 6
OPERATION METHODS..........................................................................................7
INSTALLATION............................................................................................................8
WATER DRAINAGE METHODS
............................................................................10
MAINTENANCE.........................................................................................................11
INSTALLATION ACCESSORIES........................................................................13
TROUBLE SHOOTING ........................................................................................... 12
APPENDIX...................................................................................................................14

2
IMPORTANT SAFEGUARDS
Important Safeguards.
•Read all instructions carefully.
•Disconnect the power plug before dismantling, assembling or before
cleaning.
•Avoid touching any of the appliance s moving parts .
•Never insert fingers, pencils or any other objects through the guards whenever
the power plug is connected, especially while running.
•The appliance is not intended for use by young children or uninformed persons
unless they are ade quately supervised by a responsible person to
ensure that they can use the unit safely.
•Young children should be supervised to ensure that they do not play with the
appliance.
•Do not use the appliance for any other purpose than its intended use.
•The appliance must not be used if the guards are not fastened according to
instructions.
•When the power cord is damaged, it must be replaced.
•Do not use your appliance with an extension cord unless it has been checked
and tested by a qualified electrician or electrical supplier.
•The air conditioning unit must always be stored and transported upright,
otherwise you may cause irreparable damage to the compressor; in
case of doubt we suggest to wait for at least 24 hours before you start
the air-conditioning unit.
•Avoid restarting the air conditioning unit unless 4 minutes have passed since
being turned off, or the compressor may get damaged.
•Never use the mains plug as a switch to start and turn off the air conditioning
unit. Use the provided ON/OFF switch located on the control panel.
•Always place the portable air conditioner on a dry stable surface.
’

3
Energy Saving Tips.
Do not cover or restrict the airflow from the Outlet or Inlet grills.
The minimum distance from furniture and walls should be 50cm.
Keep blinds and /or drapes closed during the sunniest part of the day.
Keep the filters clean. Under normal conditions, the filters should be
cleaned approximately every 30 days. Since the filters remove airborne
particles, more frequent cleaning maybe necessary, depending on the
indoor air quality.
Set the fan speed switch to high cool and the thermostat to the coolest
position for the initial start-up, then set the Fan switch to Low cool and
lower the thermostat to a comfortable setting.
40℃.
SSuggggeessttiioonn::
We suggest you do not use the machine if the ambient temperature
is higher than

4
FEATURES AND PARTS LIST
Features:
·No installation is required.
·Easily moved . The handle makes moving more convenient.
·LED colourful screen display.
·Water-cooled mode saves energy and is environment friendly..
·Low noise and strong performance.
·Unique economic function.
·Auto swing makes air flow from left to right automatically.
·Three-minute restart delay to protect compressor.
Parts list:
1. control panel
2. horizontal louvre
3. vertical louvre
4. air inlet grill
5. castor
6. exhaust duct
7. handle
8. air outlet grill
9. power cord and plug
10.water refill port
11.power cord hook
12.air filter

5
PANEL CONTROL
CAUTION: If the unit is turned off in cool /dry mode and restarted
immediately , then it will wait at least 3minutes before running again.
1. Buttons
Timer: press this button to set the timer
Swing: press this button to make the vertical louver swing automatically.
Press once again, the swing will stop.
Speed: press this button for 5 seconds to select high, middle or low fan
Speed.
Up/down: press up or down button to set temperature or adjust the time in
Timer mode. Press both buttons to vary from Celsius to Fahrenheit.
Mode: press this button to select cool,dry or fan mode.
Econ: press this button to a set energy saving mode.
The set temperature is 27℃in cool mode.
The fan sp eed is low. This data can’t be changed. The LED
display will flash . Press again to cancel it when is flashing.
Power: press this button to turn on/off the unit.
2. LED display
Timer indicator
Dry, cool, fan mode indicator.
High, middle and low fan speed indicator
Water Full indicator
Add Water indicator
IR receiver window
Indicate the time and te mperature. Display EX (X=2,3) when
there is something wrong (refer to Self diagnosis function).
Display E4 when coil is defrosted.
Celsius degree and Fahrenheit degree indicator.

6
REMOTE CONTROL
Power Press this button to turn on/off the unit.
Timer Press this button to set the timer.
Swing Press this button to make the vertical
louvre swing automatically.
Vary from Celsius degree to Fahrenheit
degree.
Cool Press this button to choose Cool mode.
Dry Press this button to choose Dry mode.
Fan Press this button to choose Fan mode.
Up Press Up or Down button to set temperature
Down or adjust the time in Timer mode.
High Press this button to select high fan speed.
Med Press this button to select middle fan speed.
Low Press this button to select low fan speed.
Econ Press this button to a set energy saving mode only in Cool.
The set temperature is 27℃in cool mode.
The fan speed is low. This data can’t be changed.
NOTE: To vary from Celsius to Fahrenheit press both Up
and Down buttons at least 2 seconds.
Fig.4
remote control
,

7
OPERATION METHODS
Timer set
1.Set timer -off
Press the Timer button when the unit is on. The LED will flash_ _five times.
During this period press Up or Down button to adjust set time from
0.5h to 24h. It will vary 0.5h each time in 3h and 1h each time hereafter. The
set time will flash 5 times after adjusting. When it will display temperature
again. Once the set time end, the unit will turn off automatically.
2. Change the set time
When Timer is on, you can check remaining time by pressing Timer button. It
will flash 5 times. Press Up or Down button to adjust set time. The set time
can also be cancelled if you press the Timer button once again during the
flashing time.
3.Set timer-on
Press the Timer button when the unit is off. Same as timer-off set. Once the
set time end, the unit will turn on automatically.
Cooling/ Dry Mode
1.Cooling mode
Press Mode button to choose Cool mode.
Press Up or Down button or to set a proper room temperature.
The range is 18~30℃(64-86°F). The temperature will increase or decrease
1℃or 1°F each time.
Press Speed button or to choose a proper fan speed.
Press Swing button or to adjust the direction of vertical louvre.
Adjust horizontal louvre by hand.
2.Dry mode
Press Mode button or to choose Dry mode. The fan speed is Low,
LED displays room temperature. These cannot be adjusted.
NOTE:
1. In cool mode, when the Add Water light illuminates, you can add
some water through the injection port before cooling operation.
2. You should drain water with the drainpipein dry mode.
The unit will stop working when water level exceeds the high level.
3. Do not use air exhaust duct when in Dry or Fan modes
4. If your room is directly exposed to the sun, draw the curtains please.
“
“

8
INSTALLATION
1.Selection of Installation Place
Install the unit on a flat and dry place.
Leave at least 50cm space around the
unit(when the hose is not connected).
(Fig.5)
2.AIR Exhaust Duct Mounting
1) Fix the square end of the exhaust duct to
the exhaust terminal of the unit.
2) Put the other end (discharge) in the
nearest window.
NOTE:
The length of the air exhaust duct is between
600cm to 1700cm or 1800cm (adapters included).
We suggest using the minimum length of the air
exhaust duct. It saves energy.
This length has been designed especially according to the
specifications of the air conditioner .Do not use an extension or
exchangefor adifferent hose asit may lead to malfunction.
3. Window Kit Installation
The window kit has been designed to fit most standard vertical and horizontal
windows. However, it may be necessary for you to modify some aspects of the
installation procedures for certain types of windows. Please refer to the
illustrations. (Fig.7 and Fig.8)
(90cm)
(130cm) (90cm)
(130cm)

9
4.Mounting illustrations
1.mounting in the wall
2.correct bending
3.wrong bending
Este manual sirve para los siguientes modelos
1
Tabla de contenidos