Cypress CDPS-CS4 Manual de usuario

CDPS-CS4
Control System
Operation Manual
Operation Manual


DISCLAIMERS
The information in this manual has been carefully checked and
is believed to be accurate. Cypress Technology assumes no
responsibility for any infringements of patents or other rights of third
parties which may result from its use.
Cypress Technology assumes no responsibility for any inaccuracies
that may be contained in this document. Cypress also makes no
commitment to update or to keep current the information contained
in this document.
Cypress Technology reserves the right to make improvements to this
document and/or product at any time and without notice.
COPYRIGHT NOTICE
No part of this document may be reproduced, transmitted,
transcribed, stored in a retrieval system, or any of its part translated
into any language or computer le, in any form or by any means—
electronic, mechanical, magnetic, optical, chemical, manual, or
otherwise—without express written permission and consent from
Cypress Technology.
© Copyright 2011 by Cypress Technology.
All Rights Reserved.
Version 1.1 August 2011
TRADEMARK ACKNOWLEDGMENTS
All products or service names mentioned in this document may be
trademarks of the companies with which they are associated.

SAFETY PRECAUTIONS
Please read all instructions before attempting to unpack, install or
operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this
equipment:
• Always follow basic safety precautions to reduce the risk of re,
electrical shock and injury to persons.
• To prevent re or shock hazard, do not expose the unit to rain,
moisture or install this product near water.
• Never spill liquid of any kind on or into this product.
• Never push an object of any kind into this product through any
openings or empty slots in the unit, as you may damage parts
inside the unit.
• Do not attach the power supply cabling to building surfaces.
• Use only the supplied power supply unit (PSU). Do not use the PSU
if it is damaged.
• Do not allow anything to rest on the power cabling or allow any
weight to be placed upon it or any person walk on it.
• To protect the unit from overheating, do not block any vents or
openings in the unit housing that provide ventilation and allow for
sufcient space for air to circulate around the unit.
REVISION HISTORY
VERSION NO. DATE (DD/MM/YY) SUMMARY OF CHANGE
VR0 20/07/15 Preliminary release

CONTENTS
1. Introduction............................................ 1
2. Applications........................................... 1
3. Package Contents ................................ 1
4. System Requirements............................ 1
6. Operation Controls and Functions....... 2
6.1 Front Panel ........................................2
6.2 Rear Panel.........................................3
6.3 Remote Control................................4
6.4 IR Cable Pin Assignment..................4
6.5 RS-232 DTE Pin Assignment ..............5
6.6 RS-232 and Telnet Commands .......5
6.7 Software Application.......................7
6.8 Telnet Control ...................................8
6.9 WebGUI Control .............................10
6.9.1 Macro Settings ......................10
6.9.2 Extension Macro....................13
6.9.3 Command Settings...............13
6.9.4 Network Settings ...................14
6.9.5 System Settings......................15
7. Connection Diagram .......................... 16
8. Specications ...................................... 17
9. Acronyms ............................................. 18

1
1. INTRODUCTION
By entering into a new era of smart world, the trend of controlling
everything with one nger is nowadays foreseen. Control System allows
your dream come true by providing not only direct but also indirect
control interfaces for all your devices. Direct control like IR, Relay and
DC controls allow users to maintain the traditional connection control
over the device whereas, indirect control like IR Learning, RS-232,
Telnet/WebGUI controls allow users with computing system or APP to
control over the devices. Overall, the management of all the controls
can be operated easily through IR remote control, RS-232, Telnet or
Ethernet protocols.
2. APPLICATIONS
• Smart Home Installation
• Even hall/Showroom control
3. PACKAGE CONTENTS
• 1×Control System
• 1× IR Learner Cable
• 4× IR Blaster Cables
• 4×3.5mm to 3.5mm IR Cables
• 4×Terminal Block Jacks
• 1×Remote Control
• 1×5 V/2.6 A Power Adaptor
• 1×Left and Right Rack Ears
• 1×Operation Manual
4. SYSTEM REQUIREMENTS
Input source equipment such as light, TV, power switch and ….etc.
and PC/Laptop.

2
5. FEATURES
• Supports IR Learning function allows IR signal to be accepted by
computing system
• Supports eight inputs with voltage of 0~15V
• Supports 1 IR Learning, 8 IR outputs, 8 trigger inputs, 8 Relay outputs,
2 COM ports, and 4 Ethernet ports
• Supports Baud rate from 4800bps to 115200bps
• Supports 10/100 Ethernet network connection
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
12345678
RELAY
INPUT
IR
COMMS
1 6
5
2 4
3
1POWER LED: This LED will illuminate when the device is switched on.
2IR WINDOW: Receives IR signal frquency from the remote control
and can trigger macro even 1~8.
3RELAY LED: These LEDs represent the relay output connections
status.
4INPUT LED: These LEDs will illuminate when trigger the input
connection obtain active high DC of 5~15V which is also when
signals has been triggered.
5IR LED: This LED will illuminate when the device is receiving or
sending IR signal, under IR Learning process the LED will illuminate
also.
6COMMS LED: This LED will illuminate when the COM port is sending
or receiving data, under Macro run command executing the LED
will be ashing according to the numbers of command send.

3
6.2 Rear Panel
12345678 12345678
GND
INFRARED OUT
1IRL 2345678
IN RELAY OUT
COM 1 COM 2
RESET
LAN
DC 5V
1234 USB
1 62 3 4 5 5 7 8 9
1IRL: Connect with IR Receiver included in the package for IR signal
learning. Send the IR signal that is to be learned by press on the
remote control in direct line-of-sight towards the Receiver and
record the IR data into digital format from WebGUI. For software
details please refers to section 6.9.3.
2INFRARED OUT 1~8: Connect with IR Blaster for IR signal transmitting.
Place the IR Blaster in direct line-of-sight of the equipment to be
controlled.
3IN 1~8: Connect with sensor device’s signal lines such as window
security alarm, door switch, and etc… for trigger signal sending
back to Control System.
4RELAY OUT 1~8: Connect with control device’s power line cable
such as DC power supply to activate the control devices.
5COM 1~2: Connect with RS-232 devices for command sending and
controllig the devices.
6RESET: To reset IP back to factory default, press and hold the button
with pin for 10 seconds and both IR and comm LED will illuminate.
7LAN 1~4: Connect with PC/Laptop or intra-net hub and also the
LAN connection of the control devices for Telnet/WebGUI control
over the devices.
8USB: This slot is reserved for factory rmware update only.
9DC 5V: Plug the 5V DC power supply into the unit and connect the
adaptor to an AC outlet.

4
6.3 Remote Control
11~8: Press these buttons to trigger input signal
of input 1~8 for control system to activate the
corresponding command or setting.
6.4 IR Cable Pin Assignment
3
1
2
3
2
1
IR Blaster
Power
IR Signal
NC
IR Signal
Power
Grounding
IR Learner
CR-157
56
78
34
12
1

5
6.5 RS-232 DTE Pin Assignment
DATA TERMINAL EQUIPMENT
Pin Assignment
1 NC
2RxD
3TxD
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC
Baud Rate: 4800~115200bps
Data bit: 7~8 bits
Parity: None, Odd, Even
Flow Control: None
Stop Bit: 1~2 Bits
6.6 RS-232 and Telnet Commands
COMMAND DESCRIPTION PARAMETER
IPCONFIG Display the current IP
congure
NONE
SIPADDR XXX.XXX.
XXX.XXX
Set Ethernet IP address XXX=0~255
SNETMASK XXX.
XXX. XXX.XXX
Set Ethernet net mask XXX=0~255
SGATEWAY XXX.
XXX. XXX.XXX
Set Ethernet gateway XXX=0~255
SIPMODE Set Ethernet IP mode N=STATIC/DHCP
VER Show unit rmware version NONE
REBOOT System reboot NONE