CC650 Production / Industrial Hose Crimper
10
AccuCrimp ACTTM CONTROL PANEL QUICK START
While the ACTTM crimper has the ability to perform a number of
fully automatic functions, manual operation is also possible.
To make a manual crimp, two numbers are needed:
The closed diameter of the die (in either inches or mm).
The finished crimp diameter (in either in or mm)
That’s all you need to know. ACTTM does the rest.
TO MAKE A MANUAL CRIMP:
• Press START Button.
• Select CRIMP TO DIAMETER.
• Enter the closed diameter of the die set in either in or mm
and press ENTER. Note: for a 25mm die, enter 2500.
ACTTM will add the decimal point.
Decimal point entry:
For 1.56 inch entry, enter 1560 (Controller supplies 3
places for entries in inches).
For a 50.0 mm entry, enter 5000 (Controller will supply 2
decimal places for entries in mm).
• Enter the finished crimp diameter and press ENTER.
• From the ENTER CRIMP screen, press the MANUAL button
to put the crimper in manual mode.
• Confirm that the die and finished crimp diameters are correct
and that MANUAL MODE is displayed.
• Press and hold the green CLOSE button until the crimper
stops closing.
• Check the final crimp diameter. If a minor correction is
required see HOW TO MAKE MINOR CORRECTIONS.
Tip: Pressing the CHANGE DIES button allows the crimper
head to be fully opened or closed with the green OPEN-CLOSE
buttons on the controller front panel When the CHANGE DIES
button is blinking the dies can be opened and closed manually
without altering any of the crimper settings.
Note: When using the overbore (OB) dies you must
use the SAVED DIE feature. Press the USE SAVED
DIE to select the correct die set from the die memory
table.