CTR Electronics PDP Manual de usuario

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 1 3/28/2018
Power Distribution Panel
User’s Guide
Revision 1.6
Cross The Road Electronics
www.crosstheroadelectronics.com

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 2 3/28/2018
Table of Contents
1. Power Distribution Panel at a Glance..................................................................................... 4
1.1. Connection Specifications ............................................................................................... 5
1.2. Electrical Specifications................................................................................................... 6
1.3. Mechanical Specifications ............................................................................................... 6
1.4. Communication Specifications......................................................................................... 6
2. Installing a PDP ..................................................................................................................... 7
2.1. Battery harness ............................................................................................................... 7
2.1.1. Split Washer.............................................................................................................. 8
2.2. Breakers.......................................................................................................................... 9
2.2.1. Snap Action 40 Amp Breaker.................................................................................... 9
2.2.2. Snap Action 20/30 Amp Breaker..............................................................................10
2.3. Weidmuller Connectors ..................................................................................................11
2.3.1. roboRIO, PCM, VRM................................................................................................12
2.3.2. CAN bus ..................................................................................................................13
2.4. Blade Fuse.....................................................................................................................14
2.4.1. Blade Fuse Replacements.......................................................................................15
2.5. WAGO OperatingTool.....................................................................................................15
3. LED States............................................................................................................................16
4. Functional Limitations (software)...........................................................................................17
4.1. Firmware <1.40: If Robot Is Enabled/Disabled/Enabled Quickly, FRC robot may
momentarily disable...............................................................................................................17
4.2. Firmware <1.40: Power and Energy ...............................................................................17
4.3. LabVIEW: Energy signal is not scaled to Joules.............................................................17
4.4. C++/Java: Energy signal is in Millijoules.........................................................................17
4.5. Firmware <1.37: Current may read ~2A when there is no current...................................17
4.6. FRC2016 roboRIO: CAN Device does not appear in web page diagnostics. ..................18
4.7. FRC 2018: CTRE CAN Receive Timeout........................................................................19
5. Troubleshooting Tips and Common Questions......................................................................20
5.1. What is the threshold for Vbat fault?...............................................................................20
5.2. Are sticky faults cleared during/after a firmware field-update?........................................20
5.3. Do I need to firmware-update? Where are the files?......................................................20

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 3 3/28/2018
TO OUR VALUED CUSTOMERS
It is our intention to provide our valued customers with the best documentation
possible to ensure successful use of your CTRE products. To this end, we will
continue to improve our publications, examples, and support to better suit your
needs.
If you have any questions or comments regarding this document, or any CTRE
product, please contact support@crosstheroadelectronics.com
To obtain the most recent version of this document, please visit
www.ctr-electronics.com.
6. Revision History....................................................................................................................21

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 4 3/28/2018
1. Power Distribution Panel at a Glance

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 5 3/28/2018
1.1. Connection Specifications
●Battery
○Bushings Lugs x 2
○Thread M6x1 (10mm Length)
●Power Channels (All Channels provide battery power)
○WAGO Connectors
■8 Red Channels 4-11
●30 Amp
■8 Red Channels 0-3, 12-15
●40 Amp
■Black terminals are common
○6 Position Weidmuller Connector
■PCM, VRM Supply
●20 Amp fused (ATM blade mini fuse)
■roboRIO Supply
●10 Amp fused (ATM blade mini fuse)
■Max: 16 AWG
■Min: 24 AWG
See Section 2.3. Weidmuller Connectors for wire insert instructions.
●CAN
○4 Position Weidmueller Connector
■Yellow CAN High x 2
■Green CAN Low x 2

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 6 3/28/2018
1.2. Electrical Specifications
Input Voltage (Vbat)
5.5-16 V
Absolute Max Input Voltage(1)
0 - 20 V
Output Voltage
●Channels 0-3, 12-15
Vbat - 40 A
●Channels 4-11
Vbat - 20 or 30 A
●VRM, PCM Weidmuller
Vbat - 20 A fused
●Controller Weidmuller
Vbat - 10 A fused
Note 1: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a
stress rating only and functional operation of the device at those or any other conditions above those indicated in the operation
listings of this specification is not implied. Exposure to maximum rating conditions for extended periods may affect device reliability.
1.3. Mechanical Specifications
Length
7.586 in.
Width
4.748 in.
Height
1.422 in.
Weight
1 lb. 5.3 oz.
1.4. Communication Specifications
Baud Rate
1 MB/s
CAN Termination
120 Ohm (jumper placed in the ON position).
None (jumper missing or placed in the OFF
position).
CAN High / Low
2 Ports

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 7 3/28/2018
2. Installing a PDP
2.1. Battery harness
●Components
○QTY 2 - M6x1 Bolts (10mm Length) Socket Head Cap Screws
○QTY 2 - 6mm Split (Lock) Washers
○Battery Cover
■QTY 2 - 6-32 (1/2” Length) Battery Cover Flat-Head Socket Cap Screw
○12 Volt Supply (Battery, Power Supply, etc...)
Warning:Do not reverse the battery voltage as this can cause permanent damage to
current sense circuitry. Additionally the FRC Control System Components that
draw power from PDP may not have reverse battery protection, and can also be
damaged in a reverse battery event.

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 8 3/28/2018
2.1.1. Split Washer
Warning:Care should be taken to ensure the split washers are installed under the
screw head. If this is not done, the robot could exhibit several forms of power/brownout
issues as the cable harness loosens over time.

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 9 3/28/2018
2.2. Breakers
2.2.1. Snap Action 40 Amp Breaker
●Channels 0-3, Channels 12-15
○40 Amp Breaker
○Limits Closest Red WAGO
○Supplies Battery Power
Warning: Inductive loads (motor, compressor) must have a power management device
(motor controller, PCM, spike) between itself and the PDP. No inductive loads (motor,
compressor) may be directly connected to the PDP channels as this can damage current
sense circuitry.

PDP User’s Guide
3/28/2018
Cross The Road Electronics Page 10 3/28/2018
2.2.2. Snap Action 20/30 Amp Breaker
●Channels 4-11
○30 or 20 Amp Breaker
○Limits Closest Red WAGO
○Supplies Battery Power
Warning: Inductive loads (motor, compressor) must have a power management device
(motor controller, PCM, spike) between itself and the PDP. No inductive loads (motor,
compressor) may be directly connected to the PDP channels as this can damage current
sense circuitry.