Range 0~100%LEL
Wi-Fi Gas Leak Detector
User Guide

Introduction
This product is designed to detect explosive gases(natural gas and
LPG) in the air for houses, offices and similar places etc. In case of
gas leak, it alarms sound with voice prompt, push text notification to
your mobile and drives the valve/manipulator to turn gas leak
source off.
It is also a fire alarm device with the built-in heat sensor designed to
respond when the convected thermal energy of a fire increases the
temperature.
You can get the gas level and temperature via a mobile application
from any point of the world, and an Internet connection via a Wi-Fi
802.11 b/g/n(2.4GHz) network is required for operation.TFT color
LCD screen displays with date and time, gas level, temperature and
life days remained
.

Specifications
Power supply
Micro USB+5V/1A
Consumption
<200mA
Detecting gas
Natural gas(CH4), LPG
Working Environment
Temperature:-10~55℃
Humidity:<95%RH
( non-condensing )
Sample
Diffusion
Range
0~100%LEL
Alarm setting value
6%LEL
Tolerance
±3%LEL
Response time
≦30 seconds
Heat alarm value
57℃
Alarm volume
≧70dB
Alarm with
Indicator, sound, voice prompt and APP
notification push
Valve/manipulator
drive output
12V/300mA output for 15 seconds
Warm-up time
180 seconds
Sensor life
5 years
Wi-Fi
2.4GHz
IEEE802.11b/g/n
Dimensions
86x86x24.5mm

In the box
Gas leak detector x1
Power adapter x1
Mounting adhesive tap x1
Screws x2
User guide x1
At a glance
USB+5V
power port
Wi-Fi configuration/
Clock adjustment/
Test/Silence button
Red alarm
indicator
Yellow fault
indicator
Green power
indicator
Yellow life
indicator
Display screen

Indicators
Indicator
What you see
What it means
Power
Green
Power is ok
Alarm
Blinking red
Gas leak or heat alarm
Fault
Blinking yellow
Sensor is fault
Life
Blinking yellow
Sensor life is over
Middle socket is for
manipulator
Right socket is for
valve control
Bracket

APP
Scan the QR code or find “Smart Life” from GooglePlay/APP Store to
get the free application for Android or iOS. Upon installation of APP
on your phone, the app will guide you through registering, connecting
the detector to the internet.
Add your detector
1) Smartlink(EZ) mode
Tap Add Device or “+”, select Security & Sensors from Add
Manually, then tap Gas Detector(Wi-Fi). Choose your local
Wi-Fi and input password(Only 2.4GHz Wi-Fi network is
supported).
Power your detector off. Press and hold the button, then
power your detector on, don’t release until the screen says
“Smart Mode, Connecting”.
Tap Fast flashing, wait the configuration finishes.Tap to
name your detector ,then tap Done.
2) Soft AP Mode
Please change to Soft AP Mode if the configuration fails in
Smarlink Mode.
Power your detector off. Press and hold the button, then
power your detector on, don’t release until the screen says
“Smart Mode, Connecting”.Click the button again and the
screen says “AP Mode, Connecting”.。
Tap the top right icon in APP to select “AP Mode”, then tap
“Slow flashing”.
Tap Confirm > Go to Connect, then choose the Wi-Fi
hotspot named “Smartlife-XXXX” in your Wi-Fi list. Go back to
your app to wait the Wi-Fi configuration finishes

Installation
Do not install the detector
Where the temperature is under 0℃and over +55℃or outdoor
Near to exhaust fan, vaporous, chimney hood, smelly places
Location of the detector should not be very close to apertures and
ventilation channels as air stream may be greater and gas
concentration may decrease.
Location
Natural gas that is comprised of methane gas is lighter than air, in
case of gas leakage; gas rises towards ceiling and accumulates in
areas near ceiling. Therefore, for natural gas, the alarm apparatus
shall be located in a position of 30 cm under the ceiling and 1.5-4
meter(s) away from gas supply. LPG that is comprised of mixture
of propane and butane is heavier than air. In case of gas leakage,
LPG falls down to ground. Therefore, for LPG, the alarm apparatus
shall be located in a position of 30 cm above the floor and 1.5-4
meter(s) away from gas supply.

Installation
1) Using screws
Screw the bracket to the ceiling or wall with the included
screws.Holding your detector against the bracket and turn it
clockwise to fix it in the bracket.
2) Using adhesive tap
Tear off one side of the double-sides adhesive tap and stick it to
the underside of detector, tear off the other side and attach
detector to a flat surface.

Usage
Warm-up
After power on, the detector will warm-up within 180 second and
screen says “Waiting” with countdown ticking sound.
Working
The screen displays the working window and clock panel per 1
minute in turn.
Wi-Fi icon
Connected to network with dot.
Offline if it is shown in gray.
None means Wi-Fi module failure.
Life
Days remained
Fault is shown at sensor
fault
Hour
Temperature
around
Minute

Gas leak alarm
When a gas leak is detected,the
level ring is displayed and
“There is a gas leak. Check
now”is heard. When gas leak
level raises continuously and
preset level is reached, the
detector alarms sound, the red
alarm indicator flashes,
you hears “Emergency. There is a gas leak. Don't use any
electrical switches and naked flames.Get out and call for help
now”, a notification “Gas leak detected”is pushed to your mobile
and valve/manipulator is drove to turn the gas source off.
Heat alarm
When the temperature around
detector increases to preset
value, the red alarm indicator
flashes, the value ring is
displayed ,“Heat alarm. Check
now” is heard and a same text
notification is pushed to your
mobile.
Silence
In case of alarm, click the button or tap in APP to mute the alarm
sound and the screen says “Alarm has been hushed”with the same
voice prompt.
Restore to normal from alarm
The alarm is cancelled automatically with clear air and the
temperature around detector is lower than alarm setting value.
Tabla de contenidos
Manuales populares de Detector de gas de otras marcas

Macurco
Macurco GD-6 Manual de usuario

Evikon
Evikon E2632 Manual de usuario

Critical Environment Technologies
Critical Environment Technologies CGAS-A Series Manual de usuario

MSA
MSA altair 5 Manual de usuario

DOD Technologies
DOD Technologies ChemLogic CL96 Manual de usuario

DEGA
DEGA NS III LCD Series Manual de usuario