Installation Instructions
Mortise Lockset
For ML20800 TCAC2 Series
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installation may result in damage to the lock and void the factory warranty.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
FM224 10/18
For installation assistance contact Corbin Russwin Inc., at 1-800-810-WIRE (9473)
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
1 2 3
4
7
5
8
0
6
9
#
*TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Access 800
®
®
ASSA ABLOY
Attention Installer
In U.S.:
Corbin Russwin, Inc.
225 Episcopal Road
Berlin, CT 06037 USA
www.corbinrusswin.com
In Canada:
ASSA ABLOY Door Security Solutions Canada
160 Four Valley Drive
Vaughan, Ontario, Canada L4K4T9
www.assaabloy.ca
WARNING
This product can expose
you to lead which is
known to the state of
California to cause cancer
and birth defects or other
reproductive harm. For
more information go to
www.P65warnings.ca.gov.
08/2018

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
2
1) Warning
2
2) General Description/Specifications/Features
3
3) ML20800 TCAC2 Series Product Illustration
4
4) Installation Instructions 5-12
5) Installation of RF Technology Lock 13
6) Operational Check 14
Table of Contents
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced TV technician for help
This Class B digital apparatus complies with Canadian ICES-003.
Warning: To comply with “Fire Listed” doors, only alkaline batteries must be used.
Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
1) Warning
7.1) Important 15
7.2) Installation Notes 15
®
7.3) Electrolynx Connector System 15
7.4) ML20800 TCAC2 Series Illustration with M861 Harness 16
7.5) M861 Forced Door Propped Door Option 17
7.6) M35 Power/Remote Unlocking 18
7) ML20800 TCAC2 Hard Wiring Instructions for Mortise 15
7.7) M35 Power/Remote Unlocking with M861 Forced
Door Propped Door Option
19

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
3
General Description
The Access 800 Mortise Lock is designed for areas which require stand-alone authorized entry.
It is a self-contained microprocessor-controlled keypad with non-volatile memory. The keypad
will hold a total of 100 (M800) or 2000 (M801, M802, M803, M804, M805, M806) different user
codes. User codes “01”, “02” and “03” are utilized for Master, Emergency and Supervisory
Codes respectively. This product is operated by six (6) “AA” alkaline batteries. Corbin Russwin
locks are designed with quality components to provide high security, performance and
durability.
Specifications
• Latch - Stainless steel • Locking side controlled by any combination of
• Deadbolt - Stainless steel keypad, proximity RF technology or key overide
• Auxiliary Latch - Stainless steel, non handed • Non-locking side retracts latch and deadbolt
• Handed - Easily field reversible without • Locks furnished for 1-3/4" doors. Can be
disassembling the lock body furnished for other door sizes upon request.
• Case - 12 gauge heavy duty wrought steel Consult factory
• U.L. Listed (3 hr.)
Features
• Low battery alert–4 chirps after standard • Operates utilizing any two to six digits per
user code entry code. Digits may be repeated and codes
• External remote “request to enter” connector may start with zero.
• Master, Emergency or Supervisory code will • Entry of a programmable number of wrong
unlock door when low battery has expired User Codes disables all codes for a
• Programming done at the keypad (Except programmable number of seconds
M802 & M805) or with a PDA using Yellow LED on solid
Accessware™ with Access HH application
Software.
• M800 allows last 15 transactions to be
• M801 - M806 allows last 2000 transactions
to be output to a PC via a PDA and
Accessware™ software
2) General Descriptions/ Specifications/ Features
output to portable printer via infrared link

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
4
3) ML20800 TCAC2 Series Product Illustration
®
ASSA ABL
OY

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
5
Verify hand and bevel of door. Illustrations shown are as viewed from the outside
or secure side of opening.
1
4) Installation Instructions
2Prep door according to supplied door marker.
FOR
USE
ON
FIRE
DOOR
NOT
Left Hand
Hinges Left.
Open Inward.
"LH"
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
"LHR"
Right Hand
Hinges Right.
Open Inward.
"RH"
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
"RHR"
7/8"
1-1/2
1/8" Dia. holes
(2) required
Slot
Attach fire stop plate
using self tapping screws
#8-32 x 1/2 long for wood &
metal doors
.C of 1-1/2 Dia
L
Outside
of Door
Hole for ribbon cable
Non Fire Rated Exterior Doors
install weather conduit.
(Hollow Doors Only)
Outside
of Door
Non Fire Rated Door
Hole for
ribbon cable
Install conduit half with recessed
panel "Not For Use On Fire Door"
visible from outside of door.
The optional conduit is available
for non fire rated doors to provide
weather protection for exterior door
applications. It is included in the M99
Weatherseal Gasketing Kit when
ordered with the device. If ordered
separately, order part number
794F929.
Fire stop plate required
for fire rated doors

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
6
RED Locking Screw
Catch Plate
Handing of Lock Body
Step 1) Move the red locking screw to
side of lock body being locked (Fig. 1)
Step 2) Push in latch then depress catch
plate with screw driver (Fig. 1)
Step 3) Pull latch out of lock body
and turn latch over (Fig. 2)
Figure 1
Figure 2
Figure 3
Figure 5
Step 4) Push in latch while holding
screw driver behind latch tail (Fig. 3)
Note: Push in latch until catch plate is
no longer depressed (Fig. 4)
Step 5) Rotate lock front to match
bevel of door as shown (Fig. 5)
MAKE SURE CATCH PLATE IS
EVEN W/TOP SURFACE
GOOD BAD
Figure 4
WARNING:
LOCK-IN CAN
OCCUR IF LATCH
IS NOT PROPERLY
INSTALLED
3
4) Installation Instructions

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
7
Lock Assembly Instructions
Align bevel accordingly. Engage 7/64 Allen wrench onto cap screw required for Step 5:3 on page 8.
Feed connector and wires through non cylinder side of door. Insert lock body into mortise cutout in door
and hold loosely in place with (2) #12x1" lock body screws.
4
(2) #12x1"
Combination Screws
Feed conn s
through non-cyl r side
Lock Body
7/64 Allen Wrench
Inside
of Door
ector & wire
inde
4) Installation Instructions

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
8
5
Spindles
Keypad Ribbon Cable
Outside
of Door
Installation of Outside Escutcheon
Ground
Wire
Gasket (optional)
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
NOTE: Key and
cylinder must be
rotated as shown
Correct Incorrect
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a
device is ordered. This kit includes gaskets and a conduit. When ordering the kit separately, order
part number 794F929. The gaskets may be used as a seal between the escutcheon and the door
surfaces.
2A. For fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through
the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon
through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is
properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lock,
ensuring the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 allen
wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder.
Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly.
Tighten (2) #12 x 1" lock body screws. Remove allen wrench.
NOTE A.
®
For MUSÉO Lever
collections ONLY.
Thread hub into lever
and fully tighten.
Align adapter hub
with square hole in
lever, keeping hub
as tight as possible.
Use Correct Spindle Orientation
STANDARD MUSÉO
Lever
Lever
GASKET APPLICATION:
Peel off the adhesive protective paper
from gasket. Feed Trim assembly motor
harness through gasket opening as
shown and firmly press gasket to
escutcheon, aligning edge of gasket
with the edge of the escutcheon.
®
ASSA ABLOY
®
ASSA ABL
OY
4) Installation Instructions
®
ASSA ABL
OY

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
9
6
Keypad Ribbon
Cable
Locate (3) oval head screws
and insert through the
escutcheon and thread
into the outside escutcheon.
Ground
Wire
Thumb Turn
Micro Switch
Installation of Inside Escutcheon
NOTE: Connectors go on only one way. Do not offset connector and be sure they are completely seated.
1. Connect ground wire to ground terminal, keypad ribbon cable connector to controller, and lock body
harness to motor connector. If you have a thumb turn, connect the male thumb turn switch connector
to the female thumb turn switch connector.
2. Align thumb turn to the vertical position.
3. Feed excess lock body harness wire back into the mortise of the door between the door cavity and
lock body, making sure no excess wire enters the cylinder hole of the lock body. (see diagram page 8)
Push excess keypad ribbon cable into the ribbon cable hole.
NOTE: For RF Technology versions refer to Section 5 to install through bolt screws.
Controller
Female Thumb Turn
Switch Connector
Male Thumb Turn
Switch Connector
Thumb Turn
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Thumb Turn Male Switch
Connector - for non
thumb turn mortise locks
the thumb turn male
switch connector may
be placed in the space
below the controller and
remain disconnected
1
Motor Connector
Ground Terminal
Red & Black
Wires
Keypad Harness (ribbon cable)
Remote Power
Connector
(M35 Remote Power
Wiring Harness also
available as part
No. 793F069)
Lock Body Harness
Lock Body
Harness
Gasket
GASKET APPLICATION:
Peel off the adhesive protective paper
from gasket. Feed Trim assembly motor
harness through gasket opening as shown
and firmly press gasket to escutcheon,
aligning edge of gasket with the edge of
the escutcheon.
Inside
of door
4) Installation Instructions

ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
10
6Installation of Inside Escutcheon (continued)
CAUTION: Do not allow lock body harness wires to enter cylinder hole in lock body. Wire
damage and/or malfunction of the lock may occur.
1. Turn inside lever to the horizontal position and rotate the thumb turn to the vertical position. Slide onto
spindle halfway. With inside escutcheon resting on spindle, be certain that all keypad ribbon cable will
remain inside ribbon cable hole, and that ground wire will not get pinched once escutcheon is
mounted. Escutcheon will not fit flush on door otherwise.
2. Insert 3 #10-24 screws through inside escutcheon and thread loosely into outside escutcheon. Check
operation of both inside and outside levers and make sure the thumb turn and key still operate the
latch and deadbolt correctly. If lock function is satisfactory, fully tighten the bottom two screws. Check
operation of both levers again. If levers move freely, tighten top screw. If levers do not move freely,
loosen bottom screws and realign the escutcheons until proper operation is obtained.
Inside
of door
Lock Body Harness - Feed excess
wire back into the mortise of the
door between the door cavity and
lock body. Do not feed excess
wires into the cylinder hole of
the lock.
4) Installation Instructions
Tabla de contenidos
Otros manuales de Cerrar de Corbin Russwin

Corbin Russwin
Corbin Russwin ASSA ABLOY MP9800 Series Manual de usuario

Corbin Russwin
Corbin Russwin ASSA ABLOY SN Series Manual de usuario

Corbin Russwin
Corbin Russwin CL3550 Manual de usuario

Corbin Russwin
Corbin Russwin ED4800 Series Manual de usuario

Corbin Russwin
Corbin Russwin Access 800 Manual de usuario

Corbin Russwin
Corbin Russwin Access 800 Manual de usuario

Corbin Russwin
Corbin Russwin CL3300 Series Manual de usuario

Corbin Russwin
Corbin Russwin CL3300 Series Manual de usuario

Corbin Russwin
Corbin Russwin ASSA ABLOY Museo MP6600 Series Manual de usuario

Corbin Russwin
Corbin Russwin CL33600 Manual de usuario