Cooper & Hunter SPWT-A01 Manual de usuario

Preface
Safety Instructions
Description
Basic Functions
Mode
Operation
Temperature
Humidity
Fan
Louver
Additional Functions
Health
ECO
Sleep
Self-cleaning
Electric Heater
Quiet
Nature Wind
Wind Free
Timer
Other Displays
Human Sense
1
1
3
4
4
5
6
6
7
7
13
14
15
16
17
18
19
20
21
22
26
27
Wired Remote Controller
Model : SPWT-A01
Operation Manual
Content
Thank you for choosing C&H commercial air
conditioner!
Please read this manual carefully before using the
wired remote controller for a proper operation, and
keep it properly.
Should you have any questions, please contact with
the dealer or our service center.
Lock
24

Please use this product properly after carefully
reading this chapter
Items in this chapter are identified as Warning .
Serious consequences that may result from
mis-operation are listed, and important safety-
related contents are given, please be sure to
observe!
Please keep this manual properly after reading
for reference at any time.
Symbols
Attention
Shortcut
indicates issues need attention.
helps to facilitate your operation.
indicates a reference page.
indicates mis-operation, which may
result in serious injury or death.
indicates prohibitions.
indicates mandatory items and
guidance for the actions of unspecific
general users.
Warning :
Installation · Electrical Construction
For installation, please entrust the distributor or the professional installation personnel.
Installation by customers themselves may lead to water leakage, electric shock, a fire, unit
falling and other injuries.
Electrical constructors must be qualified for construction. Please entrust qualified distributors
for construction.
Installation by customers themselves may lead to electric shock, a fire and other accidents.
Warning
When using medical devices and other devices
that produce electromagnetic waves, please do not
install the wired remote controller directly facing to
the transmitting surface of the electromagnetic
wave for preventing misoperation of the wired
remote controller.
In order to prevent the electromagnetic wave
propagating in the air from affecting the wired
remote controller, please place the devices that
can produce electromagnetic waves, or radio
transmitter and the like 9.84ft(3m) away from the
wired remote controller.
This is a universal controller, some of the functions have
to depend on the air conditioning systems. Connecting with
some certain types of air conditioners may voids part of the
functions given in this manual. Please contact your
distributor for details.
Do not install this product in the following places, or the keys
of remote controller will break down easily.
Places where oil (including machinery oil) sprays;
Places where a lot of sulfide gas drifts such as in hot
spring;
Places where inflammable gas may generate or flow to;
Places where strong salty wind blows such as coastal
regions;
Places with an atmosphere of acidity or alkalinity.
Preface
Safety Instructions

In Operation
Please do not operate the controller with wet hands, which may lead to
electric shock.
Please turn off the main power immediately when the safety device starts
repeatedly or the operation key acts abnormally.
Due to the possibility of electric leakage or overcurrent, accidents such as
electric shock, a fire and explosion may occur. Please contact the distributor
or our designated service center.
In case of abnormality (smell of burning, etc.), please stop operation
immediately and cut off the main power supply. Operation under abnormal
conditions may lead to failure, electric shock, a fire and other accidents.
Please contact the distributor or our designated service center.
Strictly prohibit the ingress of water during maintenance. Otherwise it may
lead to electric shock.
Do not alter the electrical wiring without permission, which may lead to major
accident.
Do not cut off the power supply within 3 minutes after pressing the key of the
controller, which may lead to misoperation.
Other Warnings and Precautions
Servicing · Relocation
Please contact the distributor or our designated service center for
servicing of the air conditioner units.
Improper servicing or installation may lead to electric shock, a fire and
other accidents.
Please contact the distributor or our designated service center for servicing
or relocation of the controller.
Improper servicing or installation may lead to electric shock, a fire and
other accidents.
Warning
Warning
Warning
Safety Instructions

3
Description
All the indications are listed for illustration, the
actual display during operation is different.
●Please tap screen with finger.
Do not touch the screen with objects with
sharp edges, or the screen may be damaged.
A. Operation Buttons
Mode
Fan
Temperature“+”
Function
Timer Louver
B. Display on LED
Temperature“-”
ON/OFF
Operation modes: "Fan" "Cool"
Louver
3D outlet
Ultra-far
Set temp/humidity/room temperature
Timed power-on/off
Check
Service code
Quiet
Health
ECO
Sleep
Self-cleaning
Boost
Electric heater
Nature wind
Test run
Filter
Centralized controller
Defrosting
3
2
1
34
33
32
35
36
37
38
39
8
7
6
5
4
22
21
20
23
24
25
26
27
28
29
30
31
9
"Dry" "Heat" "Auto"
10
Fan
11
12
13
14
15
16
17
18
19
On-site setting system address
Wind-free
Alarm
Lock
11
Display
43
8
15
6
2
Attention
7910
Reset
OK
12
13
14
15
Humn sense
16
Hot start
No function
17
18
19
20
21
Room/Set temp
22 23 24 25
26 27 28 29 30
31 32 33 34
35
36 37 38 39

4
Basic Functions
Mode
1
Preparation
Switch on.
Power supply shall be available
before operation to protect
compressor.
LCD is as shown on the right when
energized.
Do not cut off power supply in
operation season.
Press
to select operation
mode. Each press of the button,
the operation mode will switch as
the following sequence.
Only units with Cool and Heat functions for shop/office and VRF with Cool
and Heat functions for building are capable of heating. Those with cooling
function only are not capable of heating.
When connected with total heat exchanger, only air supply mode will display. Please contact the dealer for details.
When connected with double-source indoor units, FAN and HEAT display. Please contact the dealer for details.
Wired remote controller will display dry or auto-dry according to the actual condition that whether the connected
ducted type indoor units have equipped with humidity sensor or not.
For the mode described in Item 1 will be skipped automatically when it is unavailable or the connected unit type
does not support.
When connected a indoor unit with 3-Level dry, the wired remote controller can display three different levels of
dry operation: standard, C- Dry and S-Dry. Please contact the dealer for details.

5
Temperature
Start
Stop
Press『 』
The operation li up and the
unit starts running.
1
In usual mode, each press of
『 』will increase the temperature by
1℉. And rapid switching can be realized by
holding this button.
Press『 』
The operation goes out and the
unit stops.
Once heating operation is stopped, the indoor unit will supply air for around 2 minutes.
Operation

6
2
2
1
Each press of『』will increase the
humidity by 1% (max. 90%). And rapid
switching can be realized by holding
this button.
Auto-Dry mode is valid only when such function is available in the indoor unit. Please contact
the dealer for details.
When connected a dehumidifier with 3-level Dry, the left lower corner shows target humidity value in
Dry mode, and only temperature value can be adjusted. Please contact the dealer for details.
Room temperature can be displayed after special setting on controller. Please contact the
dealer for details.
In usual mode, each press of
『 』will decrease the temperature by
1℉. Rapid switching can be realized by
holding this button.
Each press of『』will decrease the
humidity by 1% (min. 35%). Rapid
switching can be realized by holding
this button.
Temperature
Humidity

7
1
Fan
Louver
1
Air volume is adjustable during Dry operation, but it is defaulted at Low by indoor unit.
Depending on the types of connected indoor units, Auto mode can display when controlling
certain indoor units by wired remote controller. Please contact the dealers for details.
AUTO can be set only when this function is available in the indoor unit.
Louver will not display when connected with an indoor unit without louver.
Louver setting when connected with common 4-way cassette type indoor units.
Press『』to start up the unit.
Press『』 to set louver direction.
Each press of the button will adjust
the direction as the following
sequence.
Press『』to set air volume.
Each press of the button the adjust the air
volume as the following:
6-level:
(Breeze → SL→ L → M → H → SH → AUTO)
4-level:
( L → M → H → AUTO )
( L → M → H → SH → AUTO)
3-level:
Attention

8
Louver
1
Press『』to start up the unit.
Press『』 to set louver direction.
Each press of the button will adjust
the direction as the following
sequence.
Options of louver setting may vary along with the types of indoor units. Please refer to the
manual of indoor unit for details.
When the louver is in operation, location display on LCD may not exactly match with the
actual location.
Sometimes the louver may not stop immediately after pressing the key.
Louver setting when connected with 3D panel
2
When and is selected and flashing,
Press『 』 and vertical louver
swings or changes the angle at stop.
Each press of the button the vertical
louver will display in a flashing
manner as the following sequence.
Press『』and vertical louver will
display in a reverse manner of the above
sequence.
When flashes for 10s, the blades
move and vertical louver starts to swing.
When other icons flash and stop after
10s, vertical louver stops at set location.

9
3
When is selected and flashing,
Press『 』 and horizontal louver
swings or changes the angle at stop
Each press of the button the
horizontal louver will display in a
flashing manner as the following
sequence.
4
When is selected, it flashes
for 10s then keep ON.
Horizontal and vertical louvers are
in swing mode at present.
5
When is selected, it flashes for
10s then keep ON.
Louvers do not display at present.
『 』
When flashes for 10s, the blades
move and horizontal louver starts to
swing. When other icons flash and stop
after 10s, horizontal louver stops at set
location.
Louver
Otros manuales para SPWT-A01
1
Tabla de contenidos
Otros manuales de Mando a distancia de Cooper & Hunter