7
W415-0814 / A / 03.17.11
When the appliance is installed at eleva-
tions above 4,500ft, and in the absence of
specific recommendations from the local
authority having jurisdiction, the certified
high altitude input rating shall be reduced
at the rate of 4% for each additional
1,000ft. Expansion / contraction noises
during heating up and cooling down cycles
are normal and to be expected.
This appliance is approved for bedroom
and bed-sitting room installations and is
suitable for mobile home installation.
NO EXTERNAL ELECTRICITY (110 VOLTS OR 24 VOLTS) IS REQUIRED FOR THE GAS SYSTEM
OPERATION.
2.3 GENERAL INFORMATION
2.4 RATING PLATE INFORMATION
BCNV40
NG LP
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 30,000 30,000
Max. Output (BTU/HR) 20,400 N/A
Efficiency (w/the fan on) 68% N/A
Min. Inlet Gas Supply
Pressure 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply
Pressure 7" Water Column 13" Water Column
Manifold Pressure (Under
Flow Conditions) 3.5" Water Column 10" Water Column
FOR YOUR SATISFACTION, ALL BURNER ASSEMBLIES HAVE BEEN TEST-FIRED TO ASSURE THEIR
OPERATIONS AND QUALITY!
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
If utilizing one of Wolf Steel's trim or surround kits, see "FRAMING" section for removal of the top extension.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
CERTIFIEDUNDER/HOMOLOGUESELON LES NORMES:CSA 2.22b-2009 &ANSI Z21.50b-2009, VENTEDGAS FIREPLACE/FOYER AGAZ VENTILE.
SERIALNUMBER/NO.DE SERIE: BGNV40/BCNV400
MANIFOLD PRESSURE: 3.5" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATERCOLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU
NOTFOR USEWITHSOLIDFUEL.FORUSEWITHGLASS
DOORSANDCOVERSCERTIFIEDWITHTHISUNITONLY.
MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
UNCOMBUSTIBLESOLIDENEDOITPASETREUTILISEAVECCET
APPAREIL.UTILISERAVECLESPORTESVITREESHOMOLOGUEES
ET COUVERTURES SEULEMENTAVECCETTEUNITE.
AVERTISSEMENT:N'AJOUTEZ PASACETAPPAREILAUCUNMATERIAUDEVANTENTRER
ENCONTACTAVECLES FLAMMESAUTRE QUE CELUI QUIEST FOURNIAVEC CETAPPAREILPAR
LEFABRICANT.
THEAPPLIANCE MUST BEVENTED USING "B" VENT. SEE OWNERSINSTALLATION MANUALFOR
VENTINGSPECIFICS.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'EVENT "B". REFERER AU MANUEL
D'INSTALLATIONDE PROPRIETAIRE POURL'EVACUATION PRECISE.
ELECTRICALRATING/ CLASSIFICATION: 115V0.82AMP, 60HZ
OPTIONALFANKIT/ ENSEMBLEDEVENTILATEURFACULTATIF: GZ550-KT
W385-0250 / D
VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, AND
BED-SITTINGROOM INSTALLATION. FOYERAGAZVENTILE.HOMOLOGUE POUR INSTALLATIONDANS UNE
CHAMBRE A COUCHER, ET UN STUDIO.
MODELBGNV40N
MODELBCNV400N ALTITUDE/ ELEVATION
INPUT/ALIMENTATION
REDUCED INPUT / ALIMENTATION REDUITE
0-4500FT(0-1370m)
30,000BTU/h
20,000BTU/h
MODELBGNV40P
MODELBCNV400P
0-4500FT(0-1370m)
30,000BTU/h
20,000BTU/h
WARNING:DO NOTADD ANYMATERIAL TOTHE APPLIANCE, WHICH WILLCOME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITHTHEAPPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTSMINIMAUXDESMATERIAUX COMBUSTIBLES:
TOP/DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 25 ¼"
"1TNEVE/TNEV0REHCNALP/ROOLF
SIDES/ COTES 0 "5UAETNAM/ELTNAM *
BACK/ ARRIERE 0
*MAXIMUMHORIZONTALEXTENSION / L'EXTENSIONHORIZONTALEMAXIMALE: 3".
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL
D'INSTRUCTIONPOURDES EXTENSIONS PLUS GRANDES.
WOLF STEEL LTD.
24 Napoleon Rd. Barrie, Ontario L4M 0G8 Canada
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
I
O
RESSURE
1
A
COLLECTEUR
INIMU
SUP
RESSION
'ALIMEN
AXIMU
SUP
RESSIO
A
E
T
L
A
U
HER,
E
ED
IT
4
F
30,00
ODEL
ODEL
W
WI
I
BY
TH
AN
B
TIB
E
PR
F
NDE
D'EN
A
T
RIZ
EXTEN
I
N
ND