COMPX eLock NARC iD Manual de usuario

NARC iD
Central Storage Unit (CSU)
Thank you for purchasing CompX NARC iD CSU with
built-in CompX eLock. The information contained in
these instructions is intended to serve as a guide to
allow NARC iD CSU to be quickly and easily put into
service. CompX eLock can be configured to work in
conjunction with existing 802.11b/g/n networks. For
complete set up instructions for networked and stand-
alone eLocks, please see the “Help” section in CompX’s
LockView v5iDPro software.
Central Storage Unit dimensions with CompX eLock installed
Central Storage Unit dimensions with CompX eLock — components
1
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
RFID antenna
(inside)
Control
electronics
Integrated
motorized
latch
Power supply
connector
Three shelves
with foam
capsule holders
Door position
switches

NARC iD Central Storage Unit — continued
NARC iD Central Storage Unit (CSU) — Instructions
2
What’s in the box?
w1 - NARC iD CSU box
w3 – shelves and foam capsule holders
w6 – #10 x ¾ Phillips pan head sheet metal screws to hang
NARC box
w1 - warranty card
w1 - serial code sticker set
w1 - in-box instructions
w1 - power supply and power supply cord
What’s needed?
wDrill
w9/64” drill bit (pilot hole for mounting screws)
w#3 Phillips bit or driver
wTape measure
Care and Cleaning
To clean the surface of the eLock, apply non-acid based
cleaner to a clean cotton cloth; do not spray cleaner directly
on the eLock.
Wipe down keypad and housing taking care around the USB
connector and edges of keypad. Wipe excess cleaner off of
all surfaces.
Installation
NARC iD CSU can be installed using the 6 predrilled key
holes and supplied #10 x ¾ Phillips pan head screws. Be
sure to mount the box in a location that provides enough
clearance for the doors to open.
The NARC iD CSU system comes with a power supply
connector intended to be connected to the 120VAC / 12VDC
power supply (provided). Insert the male end into the female
jack on the side of the NARC iD CSU box.
The power supply cord needs to be connected to the power
supply and to 120VAC.
The NARC CSU iD system comes pre-programmed with one
PIN user 12345. If access to the box is required during
installation, use the mechanical key or type 1-2-3-4-5-
ENTER to access the box.
CSU mounting
hole locations

NARC iD Central Storage Unit — continued
3
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
1. Dot matrix LCD
2. Network button (blue LED)
3. “UP” button
4. “NEXT/SELECT” button
5. “BACK/CANCEL” button
6. “MENU” button
7. “DOWN” button
8. + Button
9. - Button
10. Low battery indicator
(yellow LED)
11. Alpha-numeric keypad
12. HID Prox or HID iCLASS
reader location
(if equipped)
13. “ENTER” button
14. “CLEAR” button
1
2
3
4
5
6
78 9 10
11
14
13
12
NARC iD controller button layout
NARC Box
with NARC iD
installed Drug
Tote
Capsule Controlled
substance

NARC iD Central Storage Unit — continued
NARC iD Central Storage Unit (CSU) — Instructions
4
Unit Features:
wProvided with 802.11 b/g/n configuration that uses
the existing infrastructure for actual 2-way read/write
communication
wEach NARC iD CSU system can hold up to 3,000 Users
wOptional card reader to read existing HID Prox or HID iCLASS
credentials that can be programmed to operate each NARC
iD CSU system
wRemote Notification System with programmable escalating
alerts via SMTP email; SMS text, voice and fax (Networked
eLock & LockView Software required)
wSpring bolt latching mechanism provides automatic relocking
wDoor position switches
wMembrane keypad with stainless steel domes provides
durable performance and easy cleaning
Setting up the eLock
Getting Started Out of the Box
For Networked (802.11 b, g or N) 300 Series eLocks,
please follow the CompX eLock Database & Network
Configuration & Install Manual and the CompX LockView
Software Instruction Manual before proceeding.
The eLock is shipped in FACTORY mode.
Methods to begin building
a database of eLocks in
CompX’s LockView Software
For Networked (802.11 b, g or N) eLocks, please follow the
CompX eLock Database & Network Configuration & Install
Manual and the CompX LockView Software Instruction
Manual before proceeding.
LockView Mode Instructions
(For complete details on how to build a database of users
and eLocks, see the CompX LockView Software Instruction
Manual and CompX eLock Manual Programming Guide)
To enable the NARC iD CSU system SETUP mode you will
need the setup code for the box. Included with each NARC iD
CSU system is a Setup code that is on a set of green 2”x1”
labels. The Setup Code is the set of numbers immediately to
the right of “Setup Cd” on the green label set.
Press and hold CLEAR. The NARC iD CSU LCD will display
“Setup code needed to enter setup mode” At this screen,
type the Setup Code and press ENTER. CompX LockView
Software v5 must be installed and the eLock must be in
SETUP mode before continuing.

NARC iD Central Storage Unit — continued
5
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
There are two methods that can be used to add eLocks to
the LockView software:
Automatic Method
1. With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
2. Login to LockView.
3. After 30 seconds, the below will appear.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
4. Click Yes.
5. The below will appear.
Type in the name of the lock.
**Once a Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
6. Click Save when done.
7. Go to Lock Editor tab in Lock/User Editor.
8. Left click to highlight the name of the lock and then click Edit
Lock.
9. Verify and/or adjust all other lock parameters. (See LockView
Instruction Manual for complete details.)
10. Click OK when done.
Manual Method
1. Login to LockView.
2. Go to Lock/User Editor; Lock Editor tab and click Add Lock.
3. Enter the required information: Lock Name; Lock Serial
Number and Setup Code (supplied on green sticker set as
Setup Cd).
**Once the Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
4. Verify and/or adjust all other lock parameters and click OK.
(See LockView Instruction Manual for complete details on
these options)
5. Connect the eLock via the USB cable to the computer on
which LockView is installed.
6. After 30 seconds, the lock will be updated in LockView. Click
Refresh to prompt the update.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
Please use the LockView v5 software to create a database
of valid users and add them to the lock. This needs to be
completed before operating the lock. See LockView v5
Instruction manual for details regarding adding users to
NARC iD CSU.
Operating the eLock
Follow the instructions below to operate the eLock.
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits) and
2. Press “ENTER.”
CARD CREDENTIAL
If the eLock is equipped with a card reader
(HID Prox or HID iCLASS)
1. Present a valid card within range of the HID reader
DUAL CREDENTIAL
If the User requires a dual credential
1. Enter a valid PIN and press “ENTER” (for keypad credentials)
or present a valid card (for HID Prox or HID iCLASS).
2. Enter the second credential (4-14 digit PIN) and press
“ENTER.”
NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE
A 4 - 14 DIGIT PIN
STOP

NARC iD Central Storage Unit (CSU) — Instructions
6
NARC iD Central Storage Unit Interaction Guide
Lock Menu
To enter the Lock Menu press the MENU button on the
keypad.
You will be prompted to enter a valid credential: PIN, HID
prox or HID iCLASS card. After a valid credential is entered,
the following menu choices will appear.
The available menu choices are:
Date/Time Format
Brightness
Contrast
Beep Volume
RFID Test
WiFi Test
Use the UP and DOWN buttons to scroll through the menu
choices and hit NEXT/SELECT to activate one.
Date/Time Format
Choose the hour format (AM/PM or 24 hour) by using the UP
and DOWN keys to highlight the words to the immediate right
of HOURS. Use the +and –buttons to change the selection.
Choose the date format by using the UP and DOWN buttons
to highlight the words to the immediate right of DATE. Use the
+and –buttons to change the selection.
The available choices are:
MM/DD/YY (10/23/2019)
YYYY-MM-DD (2019-10-23)
DD-MMM-YY (23-OCT-19)
DD-MM-YY (23-10-19)
MMM D ‘YY (OCT 23’19)

7
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
NARC iD Central Storage Unit Interaction Guide — continued
Brightness
Use the +, -buttons to choose the brightness of the LCD
display. Alternately, choose 1-9 directly to choose the
brightness level. Press NEXT when done.
Contrast
Use the +, -buttons to choose the contrast of the LCD display.
Alternately, choose 1-9 directly to choose the contrast level.
Press NEXT when done.
Beep Volume
Use the +, -buttons to choose the Beep Volume. Alternately,
choose 1-9 directly to choose the Beep Volume. Press NEXT
when done.
RFID Test
This screen will turn on the RFID antennas and show real
time RFID tag reading from both antennas in the NARC iD
CSU box. Hit BACK/CANCEL to exit.

NARC iD Central Storage Unit (CSU) — Instructions
8
NARC iD Central Storage Unit Interaction Guide — continued
WiFi Test
NOTE: WiFi module in the NARC iD CSU system must be
configured and programmed before the test. See LockView
Database & Network Configurations & Installation Manual
for details.
This screen will turn on the WiFi system and connect to
the network. MAC address, IP address, Mask, and Gateway
address will be shown along with signal strength. Press
CLEAR to exit.

9
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
NARC iD Central Storage Unit Capsule Assembly Instructions
capsule
cap with
RFID tag
Put the controlled
substance into
the capsule,
verifying that the
narcotic is the
same as what is
listed on the RFID
tag, then put the
cap on the
capsule.
Line up the slots
in the cap and
capsule (to make
an alignment
tunnel), then
insert the wire
from the RFID tag.
Insert the locking
tab (arrow side
DOWN) on the
end of the wire
from the RFID tag
wire into the RFID
tag. Orientation
is CRITICAL. The
arrow on the latch
must be on the
bottom.
locking tab
arrow must be
on the bottom
to properly
engage
See color chart on page
15 for color / narcotic
matching.
1
2
4
Run the wire all
the way through
to the opposite
side of the cap.
3
controlled
substance

NARC iD Central Storage Unit (CSU) — Instructions
10
NARC iD CSU Capsule Assembly Instructions — continued
Place tote into
NARC iD box.
To ensure the locking
tab is fully inserted,
you must hear and
feel a click.
5
Close lid. Each tote
can carry a total
of 15 controlled
substances.
7
8
6
Place
capsules in
tote or CSU
cabinet.
Tabla de contenidos
Manuales populares de Almacenamiento de otras marcas

Spectra Logic
Spectra Logic T-Series Spectra T50e Manual de usuario

Panasonic
Panasonic LKM-F931-1 Manual de usuario

Tabernus
Tabernus Enterprise Erase E2400 Manual de usuario

Rocstor
Rocstor COMMANDER 3F series Manual de usuario

HP
HP P9000 Manual de usuario

Western Digital
Western Digital Ultrastar Data60 Manual de usuario











