Compliant Technologies G.L.O.V.E. GEN 3 Hoja de especificaciones

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 2of 24
1CONTENTS
2 Safety and Terms ...................................................................................................................................4
2.1 Safety .............................................................................................................................................4
2.2 Terms .............................................................................................................................................4
3 General Overview, Specifications, and Components ............................................................................6
3.1 Overview........................................................................................................................................6
3.2 Specifications.................................................................................................................................6
3.3 Training Model (CT-F2T) ................................................................................................................7
3.4 Component Identification..............................................................................................................7
4 Pre-Operational Checks .........................................................................................................................8
5 G.L.O.V.E. Use and Operation................................................................................................................9
5.1 Charging.........................................................................................................................................9
5.1.1 Generation 3 and 4 devices ...................................................................................................9
5.2 Replacing Micro-Processor..........................................................................................................10
5.2.1 GEN 3, 4 Devices ..................................................................................................................10
5.3 Digital Event Record Retrieval .....................................................................................................11
5.4 Powering On/Off..........................................................................................................................12
5.5 Activating on Subject’s Body .......................................................................................................12
5.6 Tap Test (Optional) ......................................................................................................................12
6 Medical, Physiological Effects and ExDS..............................................................................................13
6.1 Medical Considerations ...............................................................................................................13
6.2 Physiological Considerations .......................................................................................................14
6.3 Agitated Chaotic Event (ACE) previously known as Excited Delirium Syndrom (ExDS) and
Suicidal Considerations............................................................................................................................14
7 Tactical Considerations for Use of Force .............................................................................................15
8 Suggested ROE and Post-Incident Actions...........................................................................................17
8.1 Suggested ROE (Rules of Engagement) Levels.............................................................................17
8.1.1 Level 1..................................................................................................................................17
8.1.2 Level 2..................................................................................................................................18
8.1.3 Level 3..................................................................................................................................19
9 Post-Incident........................................................................................................................................19
9.1.1 CD3 Anonymous After-Action Report..................................................................................19

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 3of 24
10 Device Troubleshooting Procedure .................................................................................................19
11 Maintenance and Decontamination................................................................................................21
11.1 Precautions for Lithium-Ion Batteries .........................................................................................21
11.1.1 During Use ...........................................................................................................................21
11.1.2 During Charging ...................................................................................................................22
11.1.3 Battery Discharge.................................................................................................................22
11.1.4 Battery Storage....................................................................................................................22
11.2 Decontamination .........................................................................................................................23
12 Product Support, Warranty, and Contact Information ...................................................................24
12.1 Product Warranty ........................................................................................................................24
12.2 Compliant Technologies Contact Information.............................................................................24

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 4of 24
2SAFETY AND TERMS
2.1 SAFETY
CD3 Technology is not risk free and should be treated seriously like any other weapon. Follow all laws,
agency policies, and Tactics, Techniques, and Procedures (TTPs) when deploying the G.L.O.V.E. CD3.
2.2 TERMS
May result in injury or death if not followed or observed
May result in equipment damage or failure if not followed or observed
Informational notes or comments
CD3
Conductive Distraction and De-escalation Device
G.L.O.V.E.
Generated Low Output Voltage Emitter CD3
MAY
Optional at user’s discretion
NPI
Neuro-Peripheral Interference
ROE
Rules of engagement
SHOULD
Suggested course of action
TTP
Tactics, Techniques, and Procedures
WILL/SHALL
Mandatory and non-negotiable
ACE
Agitated Chaotic Event (ACE) previously known as ExDS (Excited Delirium
Syndrome)

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 5of 24
In order to operate The G.L.O.V.E., you must be trained and qualified on this tool. See your agency’s
instructor for training and qualification or contact Compliant Technologies for more information.
Once qualified and certified on The G.L.O.V.E., an individual’s certification is good for two years from the
date of course completion. All individuals will have to go through re-certification or instructor level
courses by the end of their second year. Failure to complete the bi-annual training will disqualify you from
using the device until you recertify.

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 6of 24
3GENERAL OVERVIEW,SPECIFICATIONS,AND COMPONENTS
3.1 OVERVIEW
The G.L.O.V.E. stands for Generated Low Output Voltage Emitter. It is a CD3 (Conductive Distraction and
De-escalation Device) available from Compliant Technologies LLC. It is a tool used within the Force
Continuum to assist Law Enforcement Corrections, Security, Military, and EMS personnel. It is not
intended to compete with or replace any existing tool but to supplement existing weapons and tools
within an agency’s policies and TTPs.
The G.L.O.V.E. is a Force Multiplier for officers operating within their agency’s current Force Continuum
when on their own or in mass.
3.2 SPECIFICATIONS
Table 1: Product Specifications
Specification
Specification Value
Available Sizes
S, M, L, XL, XXL depending on model
Battery life –continuous stimulation
2 hrs.
Battery life –standby mode
12-24 hrs.
Battery life –fully charged “shelf life”
Months, recommend charging
monthly
Charging time –full charge
2 hrs.
Power on/off mechanism
Wrist switch
Battery
User-replaceable 3.7V lithium ion
Battery lifetime
2000 charge/discharge cycles
Maximum Voltage:
210-380V (cannot go above 380V)
Maximum Current:
0.9-1.5A
Pulse Duration
105-115 us
Pulse Charge
84-125 uC
Pulse repetition rate
29.7-30.8 pps
Duty Cycle
0.32-0.35 %
Operation Temperature
14-122°F (-10-50°C)

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 7of 24
3.3 TRAINING MODEL (CT-F2T)
The CT-F2T is a special G.L.O.V.E. model designed specifically for training exercises. The CT-F2T operates
at 1/50th the power of a regular G.L.O.V.E. device. It is deal for training exercises without generating the
full effects of the G.L.O.V.E. which allows for more extensive training scenarios.
Figure 1: CT-F2T Training Model
3.4 COMPONENT IDENTIFICATION

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 8of 24
4PRE-OPERATIONAL CHECKS
All Compliant Technologies’ CD3s, including G.L.O.V.E. devices should be inspected for overall condition
prior to training or anticipated utilization. The pre-operational inspections should include a check of at
least the following items:
•Velcro adherence
•Tears or frays in materials inside and out
•General condition of Contact Pad
•Broken zippers
•Loose components
•Stains or contaminates
•On/Off Activation
•Operational “Tap Test” – Optional (See Section 0)
•Visually inspect charger and cable for frayed wiring or poor condition
•Check battery charge level
•If Generation 4 G.L.O.V.E. or higher, conduct tap test and verify recorded data via SD card or
User Management Software.
If any component is deemed unacceptable from the pre-operational checks, the device should be
removed from service.
If a single G.L.O.V.E. is inoperative, the other G.L.O.V.E. from the pair may still be utilized. A single
G.L.O.V.E. device is usually adequate for effective usage.

Compliant Technologies LLC Version 1.2
(859) 447-0576 Last updated:
P.O. Box 24714, Lexington, KY 40524 Page 9of 24
5G.L.O.V.E. USE AND OPERATION
5.1 CHARGING
5.1.1 Generation 3 and 4 devices
GEN 3 and 4 G.L.O.V.E. devices are supplied with charging USB cables and AC mains charging cube. Prior
to use, inspect all components to ensure there are no frayed or broken wires.
The Battery and Micro-Processor (“B/MP”) contains four indicator LEDs and a charging USB port. To
begin charging, first access the B/MP by unzipping the zipper pouch on the G.L.O.V.E. Connect the
supplied USB cable to the B/MP charging port and to a powered USB charger or the supplied charging
cube.
Each of the four red indicators represents ~25% of charge. While charging, the indicators will illuminate
in sequence to reflect the charging status. Once charging is complete, all four indicators will be
illuminated then turn Green in color. Disconnect the USB charging cable and close the zipper pouch
before use.
Figure 2: GEN 3, 4 charging illustration