Commend GE 800 Manual de usuario

GE 800
VERSION 1.1/1209
PRODUCT MANUAL
ENGLISH

GE 800
21.1/1209
Manufacturer’s Reference:
This equipment fulfils the requirements of the EU standard 89/336/EWG 89/336/EWG
(EN 55022/55024).
Therefore this equipment is CE-labelled.
Please keep this description in safe custody!
Application:
With regard to the CE mark, the Intercom Server is suitable for the following types of application: residen-
tial buildings, office and commercial premises, small businesses and industrial premises with public low-
voltage mains supply.
Attention:
Defective power cables of the transformer may not be repaired or changed. In case of defective power cab-
les, the whole transformer must be changed.
Mounting and installation of the centrals and of the equipment may be carried out by authorised service
personnel only.
Cards may be exchanged only while the voltage is switched off.
Before exchanging of cards, ESD precautions must be observed. The Earth terminal of the instal-
lation board G8A-GEN (see page 51) is used as grounding point for Wrist Strap Grounding.
GE 800
Version: 1.1/1209
Number of pages: 60

GE 800
1.1/1209 3
Content
Quick Start Guide 5
1. Extent of Supply 6
2. Additional Components 7
General 7
3. Assembly of components 8
Intercom Server GE 800 8
Plug-in positions of the Cards 8
Installation of plug-in cards 9
Installation Boards for GE 800 9
4. Cabling 10
Connection Intercom Server 10
Connection of IP-Intercom Terminals 11
Connection of Intercom Terminals (Digital, Analogue) 11
Connection Inputs/Outputs 13
Connection of multiple Intercom Servers GE 800 15
5. CCT-Configuration 19
Configuration via IP or RS 232 19
Networking of housings 19
Start-up of a Networked System 20
6. Licensing 23
General 23
The Licensing Process 26
Licensing in CCT 27
Licence Website 31
Licence activation at the Intercom Station 33
7. Configuration of IP-Terminals 34
System Requirements 34
Network Requirements 35
The Program IPStationConfig 35
Compatibility IP-Terminals – IPStationConfig 36
Installation 36
The Program Interface 37
Firmware Download 38
Configuration 39
Configuration CCT 44
General Information 46
Expansion 46
Line length Subscribers 46
Standard Call Numbers 47
Dynamic Audio Channel Allocation 48
Technical Data 49
Intercom Server Basic Housing GE 800 49
Power supply card G8-GEN 49
Processor Card G8-GEP 50
Networking Card G8-NET 50
LED-Status Indication 51
Power Supply Card G8-GEN 51
Processor Card G8-GEP 51
Networking Card G8-NET 52
Subscriber Cards 54
Input / Output Cards 55
Examples 57
IP-Addresses 57
IP-Addresses with Subnetting 58
Router configuration with NAT 59
Technical Support 60

GE 800
41.1/1209

GE 800 Quick Start Guide
1.1/1209 5
Quick Start Guide
The Intercom Server GE 800 has been designed to meet the internal communication demands of large
companies and organisations. Different functions of modern internal communication such as intercom,
information and control can be integrated into a single system. By means of different subscriber cards
with different feature levels and additional interfaces the central can be adapted to the individual needs
with ease.
This manual describes mounting of the hardware and start-up of the Intercom Server, Subscriber In-
terfaces and Input/Output cards. Information about the interface cards and Intercom Terminals can be
found in the respective Manuals of the products.
The following steps are required for Start-up:
This manual is split into the following areas:
1. Extent of Supply
2. Additional components
3. Assembly of the components
4. Cabling
5. CCT Configuration
6. Licensing
7. Configuration of IP-Terminals
Installation of plug-in cards
and installation boards
Connection of
IntercomTerminals
Activation of
Licences
Configuration of:
- Features
- IP-Terminals
- Networks
Connection of
additional Servers
(only in networked systems)
Configuration of Server-IDs
and IP addresses
(only in networked systems)

1. Extent of Supply GE 800
61.1/1209
1. Extent of Supply
1 Intercom Server GE 800 incl.:
19" Housing: 3 HE with snap-on lid
G8-GEB Bus PCB (with 17 slots, of which 14 are empty)
G8-GEN Power Supply Card (incl. installation board G8A-GEN)
G8-GEP Processor Card
G8-NET Networking Card (incl. installation board G8A-NET, 1m Cable)
Tool for removing of installation boards
CD „Software & Manuals“
Country specific power supply
The desired transformer (incl. mounting set for DIN rail (TS 35)) can also be ordered separately:
Type: Power supply:
C-GE800 without transformer
C-GE800EU Transformer 230 V Europe
C-GE800AU Transformer 230 V Australia
C-GE800UK Transformer 240 V UK
C-GE800US Transformer 120 V USA
Type: Power supply:
X-PA7-230VEU Transformer 230 V Europe
X-PA7-230VAU Transformer 230 V Australia
X-PA7-240VUK Transformer 240 V UK
X-PA7-120VUS Transformer 120 V USA

GE 800 2. Additional Components
1.1/1209 7
2. Additional Components
General
Additionally to the Intercom Server for Start up of the system the following components are required:
1. Subscriber Cards
Subscriber cards handle the speech communication as well as subscriber specific functions. For
connection of IP-, Digital- and Analogue subscribers various cards in 4 feature level (B, C, D and P)
are available. The cards of the higher levels contain all the features of the lower ones plus additio-
nal features. With feature level P individual feature levels can be advised to each subscriber.
2. VoIP-Cards
Due to the support of wide spread standards such as the SIP or IAX protocol various VoIP telepho-
nes or entire VoIP telephone systems can be connected to the Intercom system as subscribers with
VoIP cards.
3. Input / Output Cards
Input / output cards are used for the reading in of floating contacts and / or operating of controls
such as door openers or barriers via floating relay contacts (depending on type
controls such as door openers or barriers via floating relay contacts (depending on type).
4. Interface Cards
For integration and connection of external systems such as telephones, PCs, mobile radios, etc.
5. Connection / Network Cards
For connection / networking of Intercom Servers via LAN/WAN (TCP/IP), 2-wire lines, ISDN, multi-
plexer/ mediaconverter or the public telephone network. Connection: restricted features. Networ-
king: full range of features, centrals operate as though in one location.
6. Installation Boards
For connection of the plug-in cards with the Intercom Terminals, Interfaces, Inputs, Outputs...
7. Licenses
With licenses the functionality of the Intercom Server and the plug-in cards can be expanded.
These components must be ordered separately according to customer requirements.
Please make sure all required components are at hand before beginning with assembly.

3. Assembly of components GE 800
81.1/1209
3. Assembly of components
1. Remove lid
2. Install plug-in cards
3. Install Installation Boards
Intercom Server GE 800
The included plug-in cards G8-GEN, G8-GEP and G8-NET are pre-installed in the Intercom Server.
Attention: Cards may be exchanged only with voltage switched off.
Plug-in positions of the cards
The plug-in cards can be inserted in the following slots:
GEN GEP 12345678910 11 12 13 14 NET max.. per
housing:
G8-16A 99999999999999 -143
G8-16E 99999999999999 -14
G8-8E8A 99999999999999 -143
G8-CNET-E1 -------
9999999 -5
G8-LAN -------
9999999 -7
G8-CNET-W -------
9999999 -5
G8-AUD 99999999999999 -14
G8-IAX 99999999999999 -14
G8-IF 99999999999999 -14
G8-IP 99999999999999 -14
G8-TEL4 19-9-9-9-9-9-9-- 2
G8-GED 99999999999999 -14
G8-GEN 9- -------------- - 1
G8-GEP 9-------------- - 1
G8-GET 99999999999999 -14
G8-NET -------------- 91
G8-S0 99999999999999 -14
G8-SELCALL 299999999999999 -4
G8-TEL 99999999999999 -14
G8-V24 99999999999999 -14
G8-V24-PRO 99999999999999 -14
G8-V24-PROIP 99999999999999 -14
1Details see datasheet G8-TEL4
2A second slot of the GE 800 is occupied by the G8-V24-PRO delivered with the G8-V24-PRO.
3A maximum of 100 outputs may be switched on at the same time.

GE 800 3. Assembly of components
1.1/1209 9
Installation of plug-in cards
The plug-in cards are inserted into the 19" housing from the front panel side and fixed with the attach-
ment-clips. The corresponding installation boards are mounted at the rear of the central.
Installation Boards for GE 800
The plug-in cards can be used with the following installation boards:
9...available separately
0...included in Extent of Supply
E...via ethernet port on G8A-NET
G8A-C G8A-I G8A-K G8A-T G8A-V24 G8A-GEN G8A-NET G8A-TEL G8A-PRO G8A-EW
G8-16A 99
G8-16E 99
G8-8E8A 99
G8-CNET-E1 0
G8-LAN E
G8-CNET-W 0
G8-AUD 9*999*
G8-IF E
G8-IP E
G8-TEL4 99
G8-GED 9999
G8-GEN 0
G8-GEP E
G8-GET 9999
G8-NET 0
G8-S0 0
G8-SELCALL 0
G8-TEL 0
G8-V24 0
G8-V24-PRO 0
G8-V24-PROIP 0
G8-VOIPSERV 0
* At installation boards G8A-C and G8A-T the four relay outputs of the G8-AUD are not carried out.
Installation boards
Plug-in cards Tool for removing
of installation
boards

4. Cabling GE 800
10 1.1/1209
4. Cabling
1. Connection Intercom Server
2. Connection Intercom Terminals
3. Connection Inputs /Outputs
4. Connection of multiple Intercom Servers
Connection Intercom Server
Installation Board G8A-GEN
Installation Board G8A-NET
G8A-GEN
1
2
3
4
5
6
7
8
9
+30V
24V AC
24V AC
S1WS1W
S2
S1
IN2
IN1
MU2
MU1
S2WS2W
S1S1
S2S2
Music /
alarm
input
Floating
contacts
Grounding point
for wrist strap
grounding
Programming socket
(parallel to G8-GEN)
Door opener
e.g.:
Power supply
Wiring outputs
Grounding
1....GND
(Shield)
2....TXD
3....RXD
4....NC
5....GND
6....NC
7....NC
8....NC
9....NC
Power supply GE 800
DC
or
AC
UPLINK
DOWNLINK
OUT (GEV)
IN (GEV)
Ethernet (configuration)
Connection to network cards (G8-CNET-W, G8-CNET-E1)
or GE 700 (G7-GEV)
Otros manuales para GE 800
1
Tabla de contenidos
Otros manuales de Servidor de Commend