6
ENGLISH
Before use
Hose Connection*
Fit theincluded universal hose union onto
one of theoutlets (1 or 6)*.
Note: Theplastic plug (7) should be inserted
into theoutlet which is not being used.
A
B
Theuniversal hose union is fitted with
a38mm (1½″) and 25mm (1″) diameter
barbed hose connectors and a1″male
threaded hose connector. 38mm hoses
provide thebest capacity.
If the38mm barbed hose connector or
the1″threaded connector are to be used,
theend of thenipple should be cut off as
shown in thefigure.
Cut off thepart (B) of theuniversal hose union
that is not needed (if using large diameter hose).
* Thepump has two alternative outlets, upper
and lower. Depending on theconstruction of
thepump theupper outlet (1) provides about
10% less water flow than thelower outlet (6).
Note: Theplastic plug (7) must be inserted
into theoutlet which is not used.
Adjusting the Float Switch
Thelevel of water at which thepump starts
and stops can be adjusted by lengthening
or shortening thefloat switch cable held by
theclip (2).
• Shortening thelength of thecable between
theswitch (5) and theclip (2) will enable
thepump to start at alower water level.
• Lengthening thelength of thecable
between theswitch (5) and theclip (2)
will enable thepump to start at ahigher
water level.
2
5