CLF SPECTRUM P1 Manual de usuario

manual
WWW.CLF-LIGHTING.COM V1.0 JAN. 2019
SPECTRUM P1

table of CONTENTS
WWW.CLF-LIGHTING.COM
Power voltage
Dimensions 1
Safety Instruction 2
Fixture overview 4
Introduction 5
AC Power 5
Power voltage 5
Power cables 6
Relaying power to other devices 6
Data link 6
Tips for reliable data transmission 6
Physical installation 7
Fastening the xture to a at surface 7
Indoor IP-rated xtures 8
Setup 9
Control panel and menu navigation 9
DMX address setting 9
W-DMX control (optional ±q1 2019) 9
Control mode 10
control panel 11
Personality 11
Information 11
Factory reset 11
Dimmer CURVE 12
Onboard control menu 13
DMX protocols 14
Exploded view 15
Specications 16

Dimensions
All dimensions are in millimeters
WWW.CLF-LIGHTING.COM 1
106
278 267
360

Safety Instruction
WWW.CLF-LIGHTING.COM 2
WARNING!
Read the safety precautions in this section before installing, powering, operating or servicing this
product
The following symbols are used to identify important safety information on the product and in this manual:
DANGER!
Safety hazard.
Risk of severe
injury or death.
DANGER!
Hazardous
voltage. Risk of
lethal or severe
electric shock.
WARNING!
Fire hazard.
WARNING!
LED light
emission. Risk of
eye injury.
WARNING!
Burn hazard. Hot
surface. Do not
touch.
WARNING!
Wear protective
eyewear.
WARNING!
Refer to user
manual.
Warning! Risk Group 3 (high risk) LED product according to EN 62471. Do not look into the beam at a
distance of less than 8.3 meters from the front surface of the product. Do not view the light output with optical
instruments or any device that may concentrate the beam.
This product is for professional use only. It is not for household use.
This product presents risks of severe injury or death due to re and burn hazards, electric shock and falls.
Read this manual before installing, powering or servicing the xture, follow the safety precautions listed below and
observe all warnings in this manual and printed on the xture. If you have questions about how to operate the xture
safely, please contact your supplier.
PROTECTION FROM ELECTRIC SHOCK
• Disconnect the xture from AC power before removing or installing any cover or part and when not in use.
• Always ground (earth) the xture electrically.
• Use only a source of AC power that complies with local building and electrical codes and has both overload and
ground-fault (earth-fault) protection.
• Before using the xture, check that all power distribution equipment and cables are in perfect condition and rated
for the current requirements of all connected devices.
• Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG)
minimum conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or
equivalent) and heat-resistant to 90° C minimum.
• Use only PowerCON TRUE 1 ® cable connectors to connect to power input sockets. Use only PowerCON TRUE 1
® cable connectors to connect to power through put sockets.
• Isolate the xture from power immediately if the power plug or any seal, cover, cable, or other component is
damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs have been
completed.
• Refer any service operation not described in this manual to a qualied technician.
• Socket outlets used to supply xture xtures with power or external power switches must be located near the
xtures and easily accessible so that the xtures can easily be disconnected from power.

WWW.CLF-LIGHTING.COM 3
PROTECTION FROM BURNS AND FIRE
• The exterior of the xture becomes hot during use. Avoid contact by persons and materials.
Allow the xture to cool for at least 5 minutes before handling.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm away from the xture.
• Keep ammable materials well away from the xture.
• Ensure that there is free and unobstructed airow around the xture.
• Do not illuminate surfaces within 200 mm of the xture.
• Do not attempt to bypass thermostatic switches or fuses.
• If you relay power from one xture to another using power throughput sockets, do not connect more than 4 xtures
in total to each other in an interconnected chain.
• Connect only other xture to xture power throughput sockets.
• Do not connect any other type of device to these sockets.
• Do not stick lters, masks or other materials onto any optical component.
• Do not modify the xture in any way not described in this manual.
PROTECTION FROM INJURY
• Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the xture without
protective eyewear such as shade 4-5 welding goggles. At less than this distance, the LED emission can cause
eye injury or irritation. At distances of 3 meters and above, light output is harmless to the naked eye provided that
the eye’s natural aversion response is not overcome.
• Do not look at LEDs with magniers, telescopes, binoculars or similar optical instruments that may concentrate the
light output.
• Ensure that persons are not looking at the LEDs from within 8.3 meters when the product lights up suddenly.
This can happen when power is applied, when the product receives a DMX signal, or when SERVICE menu items
are selected.
• Fasten the xture securely to a xed surface or structure when in use. The xture is not portable when installed.
• Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices
they support.
• Allow enough clearance around the head to ensure that it cannot collide with an object or another xture when it
moves.
• Check that all external covers and rigging hardware are securely fastened.
• Block access below the work area and work from a stable platform whenever installing, servicing or moving the
xture.
• Do not operate the xture with missing or damaged covers, shields or any optical component.

WWW.CLF-LIGHTING.COM 4
Fixture overview
LCD Display
WDMX (accessoires ±Q1 2019)
AC mains power
throughput
Safety cable
attachment point
5P DMX output
5P DMX input
Omega bracket with
Quicklock # 520114/520113
(accessoires)
3P DMX input
3P DMX output
Safety cable
attachment point
AC mains power
input
G Clamp with
Quicklock # 875760
(Optional)

WWW.CLF-LIGHTING.COM 5
Introduction
powerful cold
white led par
■Impressive output
■5700K cold white LEDs
■Touring-ready, compact housing
■PowerCON TRUE in and out
■XLR3 and XLR5 pin
■9° beam angle
Using for the rst time
Warning! Read “Safety Information” before installing, powering, operating or servicing the xture. Before
applying power
to the xture:
Check that the local AC mains power source is within the xture’s power voltage and frequency ranges.
See “Power cables and power plug” on page 6. Install a PowerCON TRUE 1 ® power input connector power cable.
AC Power
Warning!Read“SafetyInformation”startingonbeforeconnectingthexturestoACmainspower.
Warning!Forprotectionfromelectricshock,thexturemustbegrounded(earthed).Thepower
distributioncircuitmustbeequippedwithafuseorcircuitbreakerandground-fault(earth-fault)protection.
Warning!Socketoutletsorexternalpowerswitchesusedtosupplythexturewithpowermustbelocatednear
thextureandeasilyaccessiblesothatthexturescaneasilybedisconnectedfrompower.
Important! Do not insert or remove PowerCON TRUE 1 ® connectors to apply or cut power, as this may cause
arcingattheterminalsthatwilldamagetheconnectors.
Important!Donotuseanexternaldimmingsystemtosupplypowertothexture,asthismaycausedamageto
thexturethatisnotcoveredbytheproductwarranty.
The xture can be hard-wired to a electrical installation if you want to install it permanently, or a power plug that is
suitable for the local power outlets can be installed on the power cable.
Power voltage
Warning! Check that the voltage range specied on the xtures serial number label matches the local AC mains power
voltage before applying power to the xture.
The xtures accepts AC mains power at 100-240 V nominal, 50/60 Hz. Do not apply AC mains power to the xture at any
other voltage than specied.

WWW.CLF-LIGHTING.COM 6
Power cables
Power input and throughput cables must be rated 16A minimum, have three conductors 1.5 mm² (16 AWG) minimum conductor size and
an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or equivalent) and heat- resistant to 90°C minimum. In the
EU the cable must be HAR approved or equivalent.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 16A minimum. Follow the plug
manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some possible pin identication schemes; if pins are
not clearly identied.
Data link
A DMX 512 data link is required in order to control a xture via DMX. The xture has 5-pin XLR connectors for DMX data input and output.
The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+) Pins 4 and 5 in the 5-pin XLR connectors are not used.
Tips for reliable data transmission
To connect the xture to data:
1. Connect the DMX data output from the controller to the 5-pin XLR connector of the nearest xture.
2. Connect the DMX output of the xture closest to the controller to the DMX input of the next xture and continue connecting xtures
output to input.
Relaying power to other devices
Warning! Do not connect more than ten xtures in total to AC mains power in one interconnected chain. Power can be relayed to another
device via the PowerCON TRUE 1 ® throughput socket.
If you daisy chain the xtures in a chain so that they all draw AC mains power via the rst xture, certain points must be respected:
• A heavy duty, three-conductor, 16 AWG or 1.5 mm2 cable with SJT or equivalent cable jacket must be used to connect the rst
xture to AC mains power.
• PowerCON TRUE 1 ® connectors must be used to draw AC mains power from the xtures power throughput sockets and yellow
PowerCON TRUE 1 ® connectors must be used to supply power at the xture’s power input sockets.
• No matter what the AC mains power voltage is, do not connect more than ten the xture in total ( including the rst xture) to AC
mains power in one interconnected daisy chain using power input and through out connectors.
WireColor(EUmodels) WireColor(USmodels) Conductor Symbol
Brown Black Live L
Blue White Neutral N
Yellow/Green Green Ground(earth) or
Table 1: Wire color-coding and power connections

WWW.CLF-LIGHTING.COM 7
Physical installation
Warning! The xture must be either fastened to a at surface such as a stage or wall, or clamped to a truss or
similar structure in any orientation using a rigging clamp.
Warning! If the xture can cause injury or damage if it falls, attach an approved safety cable to one of the safety cable
attachment points on the base (see “Fixture overview”).
Check that all surfaces to be illuminated are minimum 200 mm. from the xture, that combustible materials
(wood, fabric, paper, etc.) are minimum 100 mm. from the xture, that there is free airow around the xture
and that there are no ammable materials nearby.
Fastening the xture to a at surface
The xture can be fastened to a xed at surface that is oriented at any angle. Check that the surface can
support at least 10 times the weight of all xtures and equipment to be installed on it.
Warning! The supporting surface must be hard and at or cooling may be blocked, which will cause overheating.
Fasten the xture securely. Do not stand it on a surface or leave it where it can be moved or can fall over. Attach a
securely anchored safety cable to the safety cable attachment point (see “Fixture overview”) if the xture is
to be installed in any location where it may fall and cause injury or damage if the primary attachment fails.
1. Block access under the work area. Working from a stable platform, hang the xture on the truss with the
arrow on the base towards the area to be illuminated. Tighten the rigging clamp.
2. Secure the xture against clamp failure with a secondary attachment such as an approved safety cable
that is rated for the weight of the xture using one of the attachment points at the edges of the base (see
“Fixture overview”). Do not use any other part of the xture as a safety cable attachment point.

WWW.CLF-LIGHTING.COM 8
INdoor IP-rated xtures
CLF products are applied to ocial classied IP norm levels, for this product the IP rate is IP20.
Fixtures temperature specication
Make sure the xture is used within its working temperature range. Outside this range we cannot guarantee correct operation.
Temporary usage:
Stage event equipment is designed with temporary use in mind. Our product purpose is for theatre, festival, (disco) clubs and indoor &
outdoor concerts. Long term use is possible but keep in mind that it can bring damage to aging materials and aect the coated surface (
i.e. stainless steel). Rubber sealings will be negatively aected after long-term UV exposure and should be checked by qualied service
technicians over time.
Tighten screws too hard will also aect the IP-rating.
0
1
1
2
2
3
3
4
4
5
5
6
6
7
8
Tabla de contenidos
Otros manuales de Equipo de DJ de CLF
Manuales populares de Equipo de DJ de otras marcas

thomann
thomann Stairville DJ Lase 40-G MK-III Manual de usuario

Eagletone
Eagletone 6 Eyes Flower Manual de usuario

EuroLite
EuroLite FLD-1508 Manual de usuario

Technical Pro
Technical Pro LG8xSEA Manual de usuario

JB Systems
JB Systems Lounge Laser DMX Manual de usuario

Lightmaxx
Lightmaxx Vega Halo 90 Manual de usuario

Elation
Elation FUZE WASH Z350 Manual de usuario

Maverick
Maverick MK3 WASH Manual de usuario

Infinity
Infinity TF-260C7 Fresnel Manual de usuario

Chauvet
Chauvet EVE E-50Z Manual de usuario

Eliminator Lighting
Eliminator Lighting E 138 Manual de usuario

EuroLite
EuroLite Mini Multicolor LED Flashing Light SC Manual de usuario