4 - INSTALLATION INSTRUCTIONS
4.1 Safety ules
• Installation, modifications and maintenance of the appliance
must be carried out by authorised personnel in compliance with
current safety standards. The manufacturer declines all responsi-
bility for failure to comply with these obligations.
• Ventilation system installation can be carried out only by expert
personnel.
• If the appliance is to be installed near walls, dividing walls, kit-
chen equipment or decorative panelling, these should be in non-
inflammable material. If not, all appliances must be coated with
thermal-insulation fireproof material. Make sure that all fire pre-
vention standards and safety precautions are strictly adhered to.
4.2 St uctu e, equipment and safety devices
of the unit
Robust steel frame, with 4 height adjustable feet.
Steel outer panelling.
4.2.1 C king z ne
• Burner with stabilized flame.
• Gas cocks with safety and adjustable from maximum to minimum.
• Thermoelectric ignition safety.
• Enamelled cast-iron pan supports.
• The bodies of the burners and the injector-holder cups are made
of aluminium, the flame spreaders are made of enamelled cast-
iron.
• 18/10 chrome-nickel steel cooking top.
• Knobs in thermosetting material.
4.2.2 Oven
The cooking chamber is made of stainless steel.
The runners for the pans are made of chromium-plated steel.
Extractable chromium-plated steel grill..
The door, with double wall and thermal insulation, is equipped with
an insulated handle and a hinge with balanced spring.
The insulation of the cooking chamber is rockwool.
Gas versi n GN 1/1
The tubular burners are in stainless steel and are resistant to thermal
and mechanical stress. Temperature adjustment between 100°C and
300°C, is made with the thermostat.
4.3 Assembly
4.3.1 Installati n premises
This is a type A1 appliance. It must be installed in an adequately ven-
tilated room in order to avoid potentially unacceptable concentra-
tions of harmful substances in the space in which the appliance is
installed. This room must meet all applicable local and national reg-
ulations.
The appliance must be installed in an adequately ventilated room in
order to ensure the air flow necessary for combustion, in accordance
with all applicable local and national regulations.
The appliance can be installed on its own or with other similar
equipment.
If the appliance is to be installed near inflammable walls, a minimum
distance of 150 mm around the sides and back should be allowed.
If this distance cannot be obtained, take proper heat-protection
action such as fitting tiles or thermal radiation protection material
to the walls.
Before connecting the appliance to the gas supply, check on the
data plate that the appliance is suitable and type-tested for the
type of gas available.
If the type of gas indicated on the data plate of the appliance does
not correspond to the gas which is present, refer to the paragraph
5.1.8 “Conversion and adaptation”.
4.3.2 Statut ry regulati ns and technical requirements
During installation of the appliance, the following regulations must
be adhered to:
• Relevant legal directives;
• Local building and combustion regulations;
• "Technical rules for gas systems" worksheet;
• "Technical rules for liquid gas" worksheet;
• “Gas installations in industrial kitchens” worksheet;
• Relative accident prevention standards;
• Local gas utility regulations;
• Local building and fire codes.
4.3.3 Installati n
Before installation, gas connection, power check, conversion or
adjustment and start up ask for gas supply company advice.
4.3.4 Gas c nnecti n
The gas connection may be made with a continuous wall, stainless
steel flexible hose with a maximum extension of 1.5 metres, in
accordance with all applicable local and national regulations. Hoses
must not pass through spaces which might become crammed with
items and they must not come into contact with any moving parts
such as drawers.
After completing gas connection, check for leaks using a special
leak-detector spray.
4.3.5 Equip tential
The appliance must be hooked up to a unipotential system.The
required terminal is located near the power cable and it is marked
by a tag with a symbol .
The manufacturers cannot be held responsible for any dam-
age due to inadequate or incorrect installation. nder such
circumstances the guarantee will be considered null and void.
7· 16
0826_GB_99 - GAS ITCHENS 01/2016