Chef's LILIUM Manual de usuario

LILIUM
Range Hood User Manual
Compliant to EEE Directive.
Please read this user manual carefully before installing or using your equipment.
Please keep this user manual in a safe place for future use.

Scope of the Range Hood User Manual
Dear customer, the following sections contain information on safe and efficient use of
the equipment. Please read carefully before attempting to install the equipment.
Points to consider before use……………………………………2
Section 1
Technical specifications .......................................................... 3
Section 2
Technical dimensions ............................................................ 4
Section 3
Wiring diagrams .................................................................... 5
Section 4
Mounting instructions ............................................................ 6
Section 5
Operating instructions .........................................................10
Section 6
Maintenance instructions ................................................... 13
Section 7
Fault Descriptions ............................................................ 14
Section 8
1

Points to consider before use
Section 1
1....Electrical connections and installation of the product must be done by qualified service personnel.
In contrary, the product's efficiency may be reduced and serious risks such as noise,
vibration and electricity leakage may occur. In addition, the warranty becomes null.
2....Operating voltage is 200-230 Volt. Do not use under lower or higher voltages.
In contrary, it leads to burnout with the motor windings, failure with the light bulbs and
damages other electrical connection members.
3....The exhaust connection of the product must be made to heating stove, natural gas, heater, ventilation duct.
In contrary, toxic gas leakage occurs or the high air pressure affects other environments.
4....The product must be connected to grounding plug.
In contrary, there is a risk of equipment damage and electrical shock.
5....Flammable food should not be cooked under the range hood.
In contrary, the equipment may take fire, electrical components and metal housing may be damaged.
6....Do not use replace the aluminium filter of the range hood with other materials.
In contrary, other materials may take fire, the suction power may be reduced in addition to the
reduction of service life.
7....Do not connect the range hood to power before completing the installation works.
In contrary, there is a risk of electrical, mechanical problems for the equipment, in addition,
electrical or mechanical accidents may take place.
8....Range hood is designed for use above the stoves in the kitchen of the houses. The product should
not be used out of its intended purpose.
In contrary, the manufacturer shall not assume any responsibility in connection with possible
problems and accidents. In addition, the warranty of the equipment becomes null.
9....Make sure that the wall where the range hood will be mounted is capable of bearing its load.
In contrary, negative consequences may occur.
10....Keep children away from the equipment and do not allow them to use it.
In contrary, negative consequences may occur.
11.... Do not touch the halogen lamp as it heats on the surface.
In contrary, various accidents may take place.
12....Ventilation in the room must be at sufficient levels when the electrical range hood is used at the same time with the
equipment fuelled with gas or other fuels. (air-filtering equipment may be excluded)
In contrary, various accidents may take place.
13....Electrical range hood must be cleaned periodically, surfaces of the product must be clean.
In contrary, oil accumulates on the range hood surface and it may cause range hood to take fire.
14....The product must be mounted on the wall in accordance with the dimensions specified in the mounting diagrams.
In contrary, the range hood may take fire, toxic gasses are not extracted and performance loss occurs.
2

3
Technical specifications
Section 2
Range hood technical specifications
Length 598/898
Control Panel Soft Touch Control
Width 500
Suction Power 550 M³
Height Min. 530 - Max. 1010
Light Power 2x20W
Motor Power 115W
Supply Voltage 220-230V 50Hz
Total Power 155W
1
2
3
4
5
Figure A1
1- Flue Top
2- 220V Cable
3- Lower Flue Panel
4- Panel
5- Control buttons
Air Outlet Pipe Diameter 120 mm/150 mm

4
Technical dimensions
Section 3
Figure A2
285
265
Min 530 - Max 1010
20
598-898
500
40
400
470
172
120
108

5
Wiring diagrams
Section 4
Figure A3
Soft touch control wiring diagram
Data cable entry
Lamp
(Max 200W)
380W
Max
220-230V 50Hz Power
input
Data cable entry
Button card
Transformer
4. Speed
N
3. Speed
2. Speed
1. Speed

6
Figure A4
1 2
Flue connection apparatus 4x50 rysb screw Ø8 mm threaded insert Ø7 mm threaded insert 3,9x9,5 rysb screw
Mounting plate 4x35 rysb screw
34 5 67
Range hood mounting distances
Mounting instructions
Section 5A
1065
190
190
Oven & Stove
1
2
7
14
Min. 65 cm
CEILING
drill with Ø8 drill bit.
drill with Ø7 drill bit.
Flue connection apparatus
Mounting plate

7
Mounting instructions
Mounting steps;
1- Drill the required holes in accordance with the distances specified in Figure A4.
2- Drive 2 x Ø8 mm threaded inserts (1) and 2 x Ø7 threaded inserts into the wall.
3-Drive 4x50 rysb screws into the threaded insert making sure that the spacing between the wall
and the screw head is 2-4 mm.
4- Lift the product, slide the screw head into the large hole on the motor connection plate & wall
mounting plate and slightly push the product against the wall and downwards, make sure that screw
heads are properly inserted into the hole.
5- Open the product cover and remove 4x50 rysb(1) screws as shown in Figure A5.
6 - Check the steps you applied and continue with the flue assembly.
Figure A5
Section 5B
Range mounting
1- Ø8 mm threaded insert
2- 4x50 rysb screw
3- Motor connection plate & wall mounting plate
4- Panel
1
2
3
4
Figure A6
Bottom view

8
Figure A7
Mounting instructions
Range hood flue assembly and completion of the mounting works
1
2
4
5
6
7
3
Section 5C
Note : You are required to buy Ø120 mm or Ø150 mm semi-rigid aluminium duct and 2 connecting clamps
for the flue assembly. We recommend you to use Ø150 mm semi-rigid duct.
1- Flue mounting apparatus
2- Ø7 Threaded insert
3- 3,9x9,5 pan head screw
4- 4x35 rysb screws
5- Flue Top
6- Lower Flue Panel
7- Motor connection & wall mounting plate
Flue assembly;
1-Insert lower flue panel into the flue top.
2- Screw the lower flue panel to the range by using 3,9x9,5 screw(8) as shown in the figure.
3- Drive Ø7mm threaded inserts into the holes drilled in accordance with the dimensions provided in Figure A4.
4- Screw the flue mounting apparatus to the wall by using 4x35 rysb(4) screws.
5- Lift the flue top and fasten to the flue mounting apparatus on sides by using 3,9x9,5 pan head screws(3) as
shown in Figure A7 and complete the mounting works.
Figure A8
2
3
4
1

9 919
9
Air directing apparatus installation process:
1- Install the hood body and chimney installation apapratus according to the instruction in the Figure A5.
2- Drill the holes of the air directing apparatus pursuant to the instructions in figure A10 and mount it by
using Ø7 dowel (3) and 3,9 x 35 rysb screw (4).
3- Mount the air directing connection plastic onto the air directing body sheet by using 4 units 3,9 x 9,5
rysb screws (6).
4-Fix the aluminium elliptic pipe (8) to the motor air outlet (9) and mount it by using the clamp (7). 5-
Raise the aluminium elliptic pipe (8) upwards and mount it to the air directing connection plastic (5) by
using a clamp (7).
6-Complete the installation process according to the instructions in Figure A8.
Section 5D
2
5
8
9
7
185
60
125
CEILING
Figure A10
1
10
drill with Ø7 drill bit.
3
6
4
Figure A9
Figure A11
Mounting instructions
1- Chimney installation apparatus
2- Air directing body sheet
3- Ø7 mm dowel
4- 3,9*35 screw
5- Air directing connection plastic
6- 3,9x9,5 rysb sheet screw
7- Ø150 mm clamp
8- Ø150 mm elliptic pipe
9- Motor air outlet
10- Hood body
Tabla de contenidos