Chago Wallbox EVB100 Manual de usuario

1
ENG
RAK 111
20.10.2016
Chago Wallbox
Installation instruction
Operation instruction

2
Contents
1. Chago Wallbox 3
2. Safety Instructions 3
3. Delivery Contains 4
4. Accessories 4
5. Installation instructions 5
5.1. Before Installation 5
5.2. Wall Bracket Installation 6
6. Supply Connection 9
7. Commissioning 10
7.1. Connecting to Chago Wallbox 10
7.2. Congurating to Chago Wallbox 11
7.3. Commissioning Standalone Charging Point 12
7.4. Commissioning Online Charging Point 13
8. User Instructions 15
8.1. User Interfaces 15
8.2. Charging 15
9. Technical Information 16
10. Warranty 17
11. Dimension Drawing 17
12. Installation / Commissioning Checklist 18
13. Maintenance / Preventive Maintenance Instructions 19
14. Troubleshooting 20
15. EVB100 Internal Circuit Example 21
16. EVB200 Internal Circuit Example 22

3
Plastic front
cover
3-color LED
indicates the
charging point’s
status
1-2 x Mode 3/ Type 2 socket outlet
Ambient light
(optional)
Painted steel
frame
RFID reader
1. Chago Wallbox
EVB100: Single charging unit
EVB200: Dual charging unit
2. Safety Instructions
• Chago Wallbox must be installed by a qualied person.
• Read this instruction manual before installation and usage of the charging point.
• The instruction manual must be stored in a safe location and be available for future installation and
service.
• Follow the guidelines in the instruction manual when installing and using the charging point.
• The installation must be done according to the local safety regulations, restrictions, dimensioning,
rules and standards.
• The information provided in this manual in no way exempts the user of responsibility to follow all
applicable rules and safety standards.
Front cover
lock

4
3. Delivery Contains
• Chago Wallbox (EVB100 / EVB200)
• Installation and Operation instruction
• Optionally Wall bracket (EVTL40.00)
4. Accessories
Wall bracket
EVTL40.00
Included on Wallbox congurations EVBx00-A/-B/-C/-D.
For other congurations please order separately.
300
45 20
25
2x Ø6
240
4x Ø7
431
241
260
200
43
320
20
320
65
452,6
429
436
2

5
Flange
KOT21715
Included in the delivery.
Note! Cable glands are not included in the delivery.
Please order suitable cable glands separately according to the used supply cable sizes, for example Ensto
KTM... cable gland series (polyamide or brass).
5. Installation instructions
5.1. Before Installation
Remove the Wallbox from it’s package. Do not scratch the surface of the Wallbox after removal from the
package.
When selecting installation site, take into accoun the following:
• The minimum space needed for operating and maintenance.
• Make sure that the wall material is suitable and robust. The mounting surface should be at and
vertical.
• In order to ensure the optimal charging performance, the charging unit should not be exposed to
direct sunlight.
Ø20.5 2pcs (Knock-outs)
Ø32.5 2pcs (Knock-outs)
0.7
ALL KNOCK-OUTS
Ø12.5 (Knock-out)
216
8
86
+0.1
-0.1

6
Step 1
• Drill screw holes for the wall
bracket.
• Place the wall bracket on the
wall using suitable screws.
min. 400 mm min. 200 mm
Recommendation
1200 mm
5.2. Wall Bracket Installation
Follow always national regulations
and site requirements

7
Step 2
• Open the front cover lock
and remove the front cover.
Note! RFID, LED module and 3G
antenna cables are attached to
the front cover. Be careful not to
break any components when you
remove the front cover.
Step 3
• Place the Wallbox on the wall bracket (1).
• Attach the top of the Wallbox on the wall
bracket using the screws included in the
package (2).
• Secure with nuts included in the package (3).
2
3
1

8
Step 4
• Remove the front DIN rail if needed to make more space for the installation work.
• Remove the ange at the bottom of the Wallbox frame.
• Open the knock out needed for the cable gland.
• Put the cable gland in place.
• Put the ange in place.
• Pull the supply cable through the cable gland approx. 600 mm.
• Remove the cable sheath approx. 200 mm measured from the cable gland exit.
• Secure the front DIN rail in place.
• Pull the supply cable leads through the plastic guide included the delivery.
• Run the supply wiring above the DIN rail in such a manner that the outlet locking system is not dam-
aging the supply wires.
• Cut the supply cable leads in dierent lengths. Leave the ground lead long enough so that if a fault
occurs it is the last one that comes loose.
• Strip the leads 25 mm and connect to the supply connectors.
• Ensure that the RFID, LED module and 3G antenna cables are routed correctly.
• Close the front cover.
Front DIN rail
Cable route
Plastic guide
Supply cables
Controller board / boards Supply connectors
DC power supply

9
6. Supply Connection
The voltage and current ratings including cables and line protector dimensioning must comply with na-
tional regulations. System dimensioning must be done by a qualied electrical designer.
Connect separate supply cables for each charging outlet.
Stranded cables are recommended in Wallbox installations.
A Residual current protection device (RCD) and a circuit breaker (MCB) for each charging outlet must be
installed in the switchboard.
Example: Supply connection for Chago Wallbox with 2 outlets
N
L3
L2
L1
2
1
N
L3
L2
L1
SUPPLY 2
1
2
N
L3
L2
L1
PE
F01
MCB
B6
N
L3
L2
L1
PE
SUPPLY 1
PE
F02
MCB
B6

10
7. Commissioning
Before commissioning the Chago Wallbox must be installed according to the installation instructions.
By default all Chago Wallboxes are operating in free charging mode (standalone operation). In this free
charging mode external communication (Ethernet, 2G/3G) is not active. If the Chago Wallbox is going to
be connected to some back-oce (online mode), rst make sure that the basic functionality is working
before establishing communication.
7.1. Connecting to Chago Wallbox
If you want to change the default settings, you must connect to Chago Wallbox via web conguration tool
to be able to proceed with the commissioning settings. Use Firefox or Windows Explorer web-browser for
conguring.
EVB100
micro USB service port
EVB200
micro USB service port
micro USB --- USB cable PCEVB
Este manual sirve para los siguientes modelos
1
Tabla de contenidos