Preface
Thanks for using CGOLDENWALL steam generator. The steam
generator has stable function and beautiful appearance, uses the
international advanced technology.
To install, operate and maintain the machine safely and correctly,
please read the instructions carefully and keep this manual for further
reference.
Please Note:
The elderly, pregnant, or patients with heart disease, high blood
pressure, diabetes or other bad health reasons cannot use this
equipment unless under the guidance of doctor.
Do not smoke, do sports and drink alcoholic drinks when do sauna.
Please leave the shower as soon as possible when feel uncomfortable,
sick or tired.
Please take good care of the children.
It is necessary to install a ventilated fan to let in the fresh air.
We will guide you online to help you solve the problem sooner
and better.
✉Email:sunflowersmile20130401@hotmail.com

3
CONTENTS
Parameters.........................................................................................4
Instructions for Installation...............................................................5
Steam Generator Location................................................................6
Water Inlet pipe.................................................................................8
Steam Outlet pipe..............................................................................9
Drain pipe and Auto drain valve......................................................10
Steam Nozzle...................................................................................10
Wiring Connection...........................................................................12
Controller Install Guide....................................................................15
Temperature Probe Install.................................................................17
Start the steam generator...................................................................18
Controller Operation Guide...............................................................18
Descaling............................................................................................20
Maintenance operation guidance........................................................20
Troubleshooting Guidance .................................................................22

4
Parameters
1.The basic parameters of the model, the outline dimensions are shown
in Table 1:
Table 1
Power/KW
Volt/Phase
Size(length*width*height)/in
3.5
220/2
13.8×7.1×9.5
4.5
220/2
17.8×7.9×12.6
6
220/2
17.8×7.9×12.6
9
220/2
17.8×7.9×12.6
10.5
220/2
19.7×8.7×15.4
12
380/3
19.7×8.7×15.4
15
380/3
19.7×8.7×15.4
18
380/3
19.7×8.7×15.4
2.The basic parameters and dimensions of the controller are shown in
Table 2:
Table 2
Model
Time/min
Temperature Range
Size(length*width*height)/in
CC-300
30~720
95 - 131℉
3.4*3.4*0.5

5
Instructions for Installation
When installing the steam generator, please note that it has been
carefully assembled and tested by our technician. The pipe installation
must be in accordance with the specifications. Or consult a professional
with local or national plumber qualification certificate for installation.
Please turn off power when installing the steam generator and confirm
whether the purchased model is suitable for your shower room.Please
refer to Table 3.
Table 3 Technical parameters
Power
(KW)
Room size
(ft3)
voltage
(V)
Phase
number
Copper
wire cable
size (mm²)
Copper wire
cable size
(AWG)
Breaker
required
(A)
3
70~105
220V
2
2.5
12
20
4.5
105~140
220V
2
4
12
32
6
175~210
220V
2
6
8
40
9
315~350
220V
2
10
8
60
10.5
315~420
220V
2
10
8
60
12
360~455
380V
3
6
10
25
15
420~560
380V
3
6
9
30
18
560~735
380V
3
6
8
40

6
Steam Generator Location
Select a location as near as practical to the shower room. Typical
locations include: closet, vanity cabinet, climate controlled attic or
basement.
1.Locate the steam bath generator within 32 feet of the shower
room.The standard length of the cable for connecting the control to the
steam generator is 32 feet. The steam generator and control must be
located accordingly
2.DO NOT install steam bath generator inside shower room.
3.DO NOT install steam bath generator outdoors or wherever
environmental conditions may affect the safety and/or performance of the
generator.
4.DO NOT install steam bath generators or pipes in an unheated
attic or any place where water may freeze.
5.DO NOT install the steam bath generator near flammable or
corrosive materials or chemicals (such as gasoline, paint thinner, etc.).
Must avoid installation in areas with high chlorine concentration (such as
swimming pool room).
6.The steam generator can be installed on the wall or on the
ground, but it must be firm. The steam generator should be installed as
close as possible to the bathtub or bathroom. To fix the machine on a
vertical wall, first loosen the 4 screws on the cover and remove the outer
cover. There is a hole in the upper left and upper right of the cover for
fixing the machine on the wall. Close the cover after fixing. In order to
provide a good maintenance service, the sign must be placed where it can
be seen, and the machine must be installed in a place that is convenient
for maintenance. Please refer to the installation diagram below.
7.It is strictly forbidden to install the machine in an outdoor, humid,

7
hot place or a place that may be frozen or corroded. At the same time, it is
strictly forbidden to install it near flammable and explosive places such as
paint, thinner, gasoline, etc. Should be placed in a dry and ventilated
place.
8.The steam generator can only be installed horizontally. Up in the
direction indicated by the arrow. Otherwise, it is strictly forbidden to
boot.
9.Provide a minimum of 12 inches at both ends and top of the
steam generator or as required for servicing.
attic floor(insulated)
suitable for installation
controller
closet
(suitable for installation)
basement
(suitable for installation)
steam generator
controller
steam jet
under the wash basin
(suitable for installation)

8
Pipe installation
The installation of water supply pipes and steam pipes should be
completed before sealing the wall.
1. Water inlet pipe:
the water inlet pipe is connected with the DN15 pipe (1/2 NPT). And a
DN15 metal hose is connected to the water inlet and water supply valve
of the machine.
Connect to cold water .
Provide a shut off valve in the water supply line upstream of the
steam bath generator.
Do not overheat inlet solenoid valve while welding connections.
Overheating will damage parts.
Flush inlet water line thoroughly before connection to unit.
Strainer recommended to install upstream of feed water connection
As required by local codes, install an approved backflow preventer.
Do not use PEX , PVC tubing or Aluminum-plastic tube

9
2. Steam outlet pipe(1/2’’ NPT):
The steam pipe should be installed with a metal pipe of corresponding
diameter or other materials with a high temperature resistance above
150 °C according to the steam port of the steam engine (Since the
ferrous metal and galvanized pipes will make the walls of the shower
room rusty and discolored, so they are strictly forbidden to use it). The
length of the steam pipe is no more than 3 meters. If the length exceeds 3
meters, then the pipe should be insulated.
1. Do not install any valve in steam line. Flow of steam must be
unobstructed.
2. Use 1/2” brass pipe or copper tubing from unit to steam head as
permitted by codes.
3. Insulate steam line using pipe insulation rated 250˚ F or higher.
4. Pitch steam line 1/4” per foot towards steam head or steam
generator to avoid valleys and trapping of condensation.
NOTE: Running the steam line down and then up will create a steam
trap blocking the flow of steam.
NOTE: A 1.5” hole in the shower room is required to mount the steam
head

10
3. Drain pipe and Auto drain valve ( 1 ⁄2’’ NPT)
The Auto drain System feature automatically drains the system following
each use.The auto drain is automatically turned on after the controller is
turned off for about 15 minutes, but it must be ensured that the main
power supply is not turned off.
1. Plumbing to be performed by a qualified plumber and shall be in
accordance with applicable national and local codes. Steam generator
drains by gravity. A drain line must be lower than the Auto Drain
System assembly. The Auto Drain System valve outlet is 1/2” NPT.
Check plumbing code for receptor, trap and vent requirements.
2. Use copper or brass nipple 1/2” NPT x 3 , 1 ⁄2” or longer (not
supplied) to connect Auto Drain valve. An arrow on the bottom of the
Auto Drain indicates the direction of flow
4. Steam nozzle:
Put the decorative cover on the steam nozzle in the shower room, apply
sealant and screw on the nozzle. Pay attention to avoid damaging the
decorative cover and nozzle by excessive force. Confirm that the steam
outlet of the nozzle is facing down (pointing to the ground).