Centrosolar TFP 288 Professional Manual de usuario

Installation Guide
www.centrosolar.com
TF Plate Professional
Installation Guide
TFP 288 Professional


Installation Guide
3
Contents
1 Aboutthisguide 2
2 Sitepreparation 2
3 Installationprerequisites 3
4 SafeInstallation 4
5 CommissioningoftheSystem 9
6 Maintenanceandcleaning 9
7 TechnicalSpecications 10
8 Warrantyandguarantee 11
9 Disclaimer 11

1 Aboutthisguide
Thank you for choosing Centrosolar TF Plate Professional.
If you have questions about the installation or components
of the system, please contact our technical support: +49
(0) 5251 500 500.
The maintenance and operation of a PV system requires
a sound technical knowledge. Therefore, any work on the
system may only be carried out by qualied and authorized
personnel. Make sure to read these assembly instructions
carefully before installing, commissioning or servicing the
system, and store these instructions in a well accessible
location. The guide is part of the product. It only applies to
the solar modules TF Plate Professional by Centrosolar
AG. Pay special attention to the information regarding safe
usage. Cetrosolar is not liable for damage resulting from
disregarding this guide.
Targetgroups
The target group of this guide, especially chapter 4 (Safe
Installation), are skilled craftsmen. Information relevant
for the operator can be found in chapter 6 (Maintenance
and Cleaning).
Informationconcerningyoursafety
orthatofthedevicearehighlighted.
Pleasenote:
Disregarding the instructions of this installation guide may
void any warranties, guaranties and product liabilities.
2 Sitepreparation
The TF Plate Professional modules are sensitive techni-
cal components, which must be handled with utmost care.
Pay special attention during transport or when putting into
interim storage on site and ensure a safe working environ-
ment.
Caution!
Enter TF Plate Professional only
withcorrespondingprotection!
Mechanical strain of the TF Plate Professional can lead to
damage of the photovoltaic cells. Therefore, stepping onto
the photovoltaic laminate is forbidden. If stepping onto the
laminate can not be avoided, use special overshoes and
protective mats or similar protective equipment, to avoid
scratching or damaging the laminate surface. Especially
stepping in between the high beading is only permissible
after proper load distribution, otherwise irreversible deec-
tions of the TF Plate Professional may occur.
Fig. 1: Stepping onto the TF Plate Professional can result in damage.
Caution!
Transportpalletsmayonlybeplaced
onsufcientlystableroofs!
TF Plate Professional is delivered on transport pallets
with considerable weight (approx. 1100 kg). A truck crane
should be used on site to hoist the pallets onto the roof.
Unpacking of TF Plate Professional takes place on the
roof. Prior to hoisting, check if the load capacity of the
roof meets the weight of the fully loaded pallets in the load
area. If in doubt consult a structural engineer.
4
Installation Guide

Fig. 2: Before placing the pallets on the roof check its load ca-
pacity!
Caution!
Protectmodulesontheroofagainst
windsuction!
After releasing the transport locks on the pallets, the mod-
ules on the roof must be protected against wind suction.
Keep suitable weight elements or belts handy on site.
3 Installationprerequisites
Checktheroofinclination:
To facilitate sufcient drainage from the modules, the roof
inclination must be at least 3°. The maximum authorized roof
inclination for the TF Plate Professional installation is 60°.
HowtousetheDC-Connectjunctionbox:
The wiring of the modules with each other, with the cor-
responding DC-Connect junction box, and/or with the in-
verter may only be accomplished using connection cables
with a diameter of at least 4 mm². With cable lengths of
more than 20 m, a cable diameter of at least 6 mm² is
recommended.
For electrical connection with the modules only use
original MC3 plugs by Multi-Contact or LC3 plugs by
Lumberg.
If more than three strings are to be connected to the
inverter in parallel, use a DC-Connect junction box to
eliminate excessive reverse electrical loads in case
of a failure.
Thin-layer modules are generally used for large sur-
faces. Due to the increasing probability of an indirect
lightning effect, we recommend the use of a surge
protector.
Ensurethatthemodulesaregroundedproperly:
In order to eliminate the risk of re or electric shock to the
highest extent, the PV module frames must be grounded
according to good professional practice. The company
carrying out the installation of the PV system is also re-
sponsible for the grounding of every individual module.
If an external lightning protection system or is already ex-
istent or planned, the PV system must be integrated into
TF Plate Prof. / TF Membrane Prof.
max. 6 strings per DC-connect are possible
DC-Connect TFP/TFM-6S
yes no
Inverter with disconnection point
DC-Connect TFP/TFM-6S
with disconnector switch
5
Installation Guide

the protection scheme against direct lightning strikes.
Country-specic regulations must be observed.
Due to the design of the TF Plate Professional it is not pos-
sible to provide the module with a xed marked grounding
point in advance. Fora professionalgroundingofthe
modulewerecommendthefollowingprocedure:
Establish grounding between two high beadings with an
appropriate grounding connector. We recommend Solklip
grounding connectors by Tyco Electronics. To secure the
grounding connector to the module, drill a hole through
the carrier plate of the TF Plate Professional at the desired
position.
Pleasenote:
It is strictly forbidden to direct articially concentrated sun-
light onto the module or panel, as this will damage the
module.
Fig. 3: Correct installation of the cable protection: top or side
(green).
Fig. 4: The cable protection must not be installed at the bottom of
the inclination (green).
4 SafeInstallation
Distancebetweenhighbeadingandlining
The free distance between the high beadings of the trap-
ezoidal sheet metal and the lining of the TF Plate Profes-
sional must not exceed 330 mm. The minimum width of
the high beadings is 35 mm.
Use self-tapping screws to secure the TF Plate Profes-
sional on the trapezoidal sheet metal high beadings.
Position the TF Plate Professional module in such a way
that the long side of the module is aligned at a right angle
to the run of the trapezoidal metal sheet.
Distancebetweenthescrewjointpositions
The distance of the individual screw joints along the TF
Plate Professional module must not exceed 688 mm. Ex-
ample:
Fig. 5
A roof with trapezoidal sheet metal type 35/207 should
look like this:
Fig. 6
Pleasenote:
The stated distances are recommended values. The ac-
tual position of the screw joints depends on the high bead-
ing pitch of the trapezoidal metal sheet.
max. 688 mm min.
35 mm
max.
330 mm
13 618 8 x 618 13
1342142113
5586
6
Installation Guide

CalibratingtheTFPlateProfessional
Determine the starting position for the laying of the rst
module (zero point). Then determine the individual posi-
tions of the screws and butyl sealing strips.
Place the screws into the carrier plate so that they corre-
spond to the dashed line of the image. The distance to the
top and bottom edge is 13 mm (A and C). The center row
(B) is centered between the two laminates. This leads to a
distance of 421 mm to the outer rows.
Fig. 7
Transfer the markings for the fastening points and the out-
er distances onto the trapezoidal metal sheet to determine
the position of the butyl sealing strips.
Fig. 8
Accuratesealingwithbutylsealingstrips.
To guarantee optimum tightness, the butyl sealing strips
must be cut to 50 mm x 50 mm and bonded to the trap-
ezoidal metal sheet at all screwing positions (Figure 9). If
the TF Plate Professional is laid with adjoining long sides,
the joint area of the two modules must be sealed with a
butyl sealing strip with the following dimensions: 100 mm x
50 mm. This will seal the opposing screwing points.
Fig. 9
IndividualLaying
With individual laying the butyl sealing strips must be put
in such a way that they are centered between the screwing
positions. However, they must not project over the edge of
the module (Figure 10).
Fig. 10
In case the high beading distance is particularly small and
the screwing points of the mounting brackets (a) for the
cable duct would therefore be on a high beading, place an
additional butyl sealing strip (b) onto the trapezoidal metal
sheet at this position (Figure 11).
PV module
Butyl strips
Trapezoidal sheet
Zero point
A
C
B
Zero point
B
A
C
13
13
421
421
max. 688 mm
Zero point
A
B
C
7
Installation Guide

Fig. 11
In case a screw connection is located directly on the edge
of the trapezoidal metal sheet, fasten the mounting brack-
et with the included MS polymer adhesive. An additional
butyl strip is not necessary.
Caution!
Fastenscrewsproperly!
Ensure a good screw connection of the module (located at
the end stops) at all predetermined points. All screws must
be tightened with a tightening torque of 5 Nm.
Fig. 12
Layingtobuttattheedges
All subsequent modules are laid to butt at the edges with
distances predetermined on site.
Fig. 13
~210 mm
8
Installation Guide

WiringInformation:TFPlateProfessional
When wiring the TF Plate Professional module, please
note that there are two electrically independent laminates
applied to the carrier sheet metal. Structurally, it is one
inseparable unit. Electrically, however, the two laminates
are independent. Therefore, laminate A can be connected
to a different string or inverter than laminate B. Likewise,
both laminates can be connected in series to one string or
one inverter.
Please note that all design programs for inverters refer to
a laminate with a power of 144 W. For an electrical view it
is therefore necessary to consider the number of the lami-
nates (twice the number of modules) and not the number
of modules.
Mountingthecableduct
Apply an approx. 6 mm wide strip of MS polymer adhesive
with a 15 mm distance to the edge of the module carrier
plate. The adhesive strip should begin with an approx. dis-
tance of 25 mm to the long side of the module and should
have a length of 810 mm. One polymer adhesive cartridge
(290 ml) is sufcient for ten to twelve modules. Observe
the manufacturer's processing information of the MS poly-
mer adhesive.
Fig. 14
Position the base plate ush with the outer edge of the
module carrier plate and in the middle of the long sides.
The short side of the base plate faces the top. Apply even
pressure to the base plate until the polymer adhesive is
distributed with a thickness of approx. 1 mm. Slight push-
ing motions in all directions are helpful.
Fig. 15
Pleasenote:
TheMSpolymeradhesivemustset
for24hoursbeforeanyfurthercable
ductworkcanbecontinued.
800 mm
~ 6 mm Ø
15 mm
9
Installation Guide

SectionalviewoftheTFPlateProfessional:
For a better understanding, we have numbered the indi-
vidual areas in the overview. The corresponding remarks
can be found below the gure.
Fig. 16
Fig. 16a
Numeric Key:
1. TF Plate Professional module with carrier plate (1a), module
laminate (1b), junction boxes (1c), cable strain relief (1d)
2. Each cable duct base plate (l = 813 mm) is bonded to a car-
rier plate (1a) on the front side with equal lateral distances.
3. Cable duct cover plate (l = 3000 mm b ~ 160 mm), screwed
to cable duct base plate and clamped to fastening buttstrap
(4)
4. Fastening buttstrap (l = 25 mm, contact with 40 mm), see
detailed image
5. MS polymer adhesive
6. Self-tapping screw VA 4,8 x 13 resp. arbitrary VA sheet metal
screw
7. Self-tapping screw 4,8 x 19 with gasket
Top view: Mounting position cable duct on TF Plate
Professional
The example shows an installation with three TF Plate
Professional modules.
Fig. 17
3
3
4
6
1
7
471c 1d
1b
5
3
6
1a
2
10
Installation Guide