Capital fireplaces Curvation:Siesta Guía del usuario

Installation, Servicing & User Instructions
For use in GB & IE (United Kingdom and Ireland)
This appliance has been tested and certified for other counties (see technical data). However to install appliance in other countries,
modification of the appliance and its method of installation may be necessary in order to use the appliance safely and correctly.
The manual for the local language must be obtained. Contact Capital Fireplaces for further information.
www.capitalreplaces.co.uk

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
2
Introduction
Thank you for purchasing a Capital Fireplaces gas stove, we know that our stove will provide your home with many
years of heat and good service. We assure you that you have purchased a quality product that has been built to last,
designed and manufactured in the UK.
Please read the operation and installation guide carefully before commencing the installation and remember to keep this
manual safe for future reference.
WARNING!
The appliance will become
very hot.
During operation, the entire stove unit becomes
very hot and will cause burn injuries if touched.
Heat is also radiated from the stove, especially
the glass, and high temperatures will be emitted.
Always take care when near the re and that
there are no ammable materials closer than the
recommended distance specied.
NOTE:
Ensure you report the installation
of your stove to your local
authority.
The owner of the property is
personally responsible for ensuring
compliance with all mandatory
safety requirements and that the
installation is carried out by an
approved and qualied installer.
Contents
1. General Notes 3
2. User Instructions 4
2.1 Emergency Gas Isolation 4
2.2 First Time Of Operation 4
2.3 Control Overview 4
2.4 Manual Turn OFF 11
2.5 Cleaning And Maintenance 11
3. Installation Instructions 12
3.1 Gas Connection 12
3.2 Ventilation 12
3.3 Appliance Installation 12
3.4 Flue Connection 13
3.5 Fuel Bed Arrangements 16
3.6 Commissioning The Appliance 19
4. Servicing 20
4.1 Cleaning The Ceramics 20
4.2 Servicing The Burners 20
4.3 Spare Parts 21
5. Technical Information 22
5.1 Countries Of Use 22
5.2 Technical Data 23
5.3 Dimensions 25
Appendix 27
Appendix 1 – Mertik Fault Finding Chart 27

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
3
1. General Notes
This Capital Fireplaces gas appliance is a High Efciency, Balanced Flue Live Fuel Effect appliance.
It provides radiant and convected heat using the latest burner technology. As well as having a variable
heat output, these res also utilise a special control system that allows the appliance to use double
burners* for high output or a single burner for lower outputs.
When tted with double burner system, the front burners is designated as the “Main” Burner, the second
burner will be designated as the “Effect or Auxiliary” Burners. The Effect burner can be switched ON or
Off whilst the appliance is alight.
Before Installation, check that the local distribution conditions, nature of the gas and pressure, and
adjustment of the appliance are compatible.
This appliance is intended for use on a gas installation with a governed meter.
This Gas Installation may only be installed by a registered professional competent person (Gas Safe
installer in the UK). The installation must adhere to the requirements of the local and national Building
regulations and national standards. The installation manual must also be followed.
Ensure that the Flue Terminal is not in any way obstructed and is clear of vegetation, i.e. trees, shrubs
etc. and that no objects are leant against the terminal or guard.
Always clean the Window Panel before the re is ignited. Any nger prints must be removed, as these
will be burnt into the glass and will be un-removable.
Do not operate this appliance if the glass panel has been broken (or cracked), removed or with rebox
access panels open.
Only ue approved by Capital Fireplaces for this appliance may be used.
This appliance is a balanced ue product and is room sealed and as such requires no additional
ventilation for operation. However an adequate supply of fresh air to maintain temperatures and a
comfortable environment is recommended.
This appliance is designed as a heating appliance, and as such will get very hot in operation; all surfaces
(except the controls and access door) are considered to be working surfaces and as such should not
be touched. The front windows and surrounds are not considered to be fully secure guards against
accidental contact. It is recommended that an approved re screen be used if children, the elderly or
persons with limited mobility are to be present in the same area.
Do not place curtains, laundry, furniture etc. within a safe distance of 300mm of this appliance.
Do not attempt to burn rubbish on this appliance.
If this appliance is extinguished, on purpose or other, no attempt to relight should be made within 3
minutes.
*Not available on Single Burner models

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
4
2. User instructions
2.1 Emergency Gas Isolation
In the event of a gas leak or if gas is smelt, the appliance must be isolated. This is done by turning OFF
the gas at the Isolation Tap. This Isolation Tap is located in the foot of the appliance.
2.2 First Time of Operation
Before igniting the appliance, ensure that all packaging, safety stickers and any protective wrapping
have been removed, and that the glass has been cleaned, including all ngerprints from the glass.
Ensure that the room is adequately ventilated the rst time that the appliance is ignited; we would
recommend opening windows if possible. Run the appliance at full setting for a few hours so that the
paint gets an opportunity to fully cure. During this period it is possible for some fumes and vapours to
be given off. We would recommend keeping children and pets out of the area at this time.
2.3 Control Overview
2.3.1 Basic Manual Control
1. Igniting the Pilot Light
a) From the OFF position, depress the control knob for ve
seconds (only pilot gas ows).
b) Turn the control knob anti-clockwise through the PILOT
position and continue turning until the igniter “clicks”, if the Pilot
ame lights, hold for ten seconds (only pilot gas ows). If the
Pilot has not Ignited, return the control knob to the OFF position
and repeat.
c) Upon releasing the control knob the pilot ame should remain
alight, if not return the control knob to the OFF position and
repeat.
2. Igniting the Main Burner
The appliance should always be run on FULL for the rst 30 seconds.
From the IGNITION position, turn the control knob fully anti-
clockwise, this is the FULL position, gas should now be owing to
the main burner and the burner should light on full.
3. Adjusting the Flame Height (heat setting)
From the FULL position, turn the control clock-wise, until the control
knob reaches a stop, this is the LOW setting. Any position between
HIGH and LOW can be selected as an intermediate setting.

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
5
4. Leaving the appliance in Pilot Position
In the Pilot Position, only the Pilot ame will remain alight.
Depress and turn the control clockwise, through the LOW setting to
the PILOT setting.
The appliance can be left in this position, however we would
recommend turning the appliance OFF if not required within a few
hours.
5. Turning the appliance OFF
From any heat setting or PILOT, Depress and turn the Control knob
fully clockwise to reach the OFF position, and release the control
knob. The appliance will now be OFF.

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
6
2.3.2 Remote Control
IMPORTANT
We only recommend Duracell Ultra Power alkaline batteries.
Rechargeable batteries are not to be used. Under normal
conditions batteries should last approximately 12 months.
x4 AA Batteries required in the controller unit.
x2 AAA Batteries required in the remote control.

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
7

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
8

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
9

Curvation & Siesta Series Manual - V2.2 © Capital Fireplaces 2017
10
Tabla de contenidos
Otros manuales de Cocina de Capital fireplaces
Manuales populares de Cocina de otras marcas

Vermont Castings
Vermont Castings Intrepid 2 Manual de usuario

Italiana Camini
Italiana Camini CLASSICA Guía de inicio rápido

Avalon
Avalon Vashon Avanti DVS FS Manual de usuario

Spartherm
Spartherm ambiente a1 Manual de usuario

Dimplex
Dimplex MCFSTV12AU Manual de usuario

Warmlite
Warmlite WL46040 Manual de usuario