BVL Controls ECO-025 Manual de usuario

BVL Power Pack
Service & Specification Manual
Manufactured by BVL Controls Ltd

BVL POWER PACK
Manufactured by BVL Controls Ltd
AIR COOLED
ECO-025
1/
4
HP
R
-
134a
120 VAC
ECO-033
1/3
HP
R
-
134a
1
20
VAC
BVL-056
1/2
HP
R
-
134a
1
20 VAC
CMC-030 1/3 HP R-134a 120 VAC
CMV-030 1/3 HP R-134a 120 VAC
CWA-3
1/3
HP
R
-
404
a
1
20
VAC
CWA-2
1/2
HP
R
-
404a
1
20
VAC
CWA-34 3/4 HP R-134a 208/230 VAC
CWA-100 1 HP R-404a 208/230 VAC
CWA-175 1.75 HP R-404a 208/230 VAC
WATER COOLED
CWW-2
1/2
HP
R
-
404a
120 VAC
CWW-34
3/
4
HP
R
-
404a
208
/230
VAC
DESCRIPTION
COOLING DISTANCE (from cooler to faucet)
ECO-025 UP TO 25’
of cooling line
or ice tower
ECO-033 UP TO 60’
of cooling line
BVL-056 Depends on pump used
CMC-030 UP TO 90’
of cooling line
CMV-030 AVAILABLE SOON UP TO 100’
of cooling line
CWA-3 UP TO 125’
of cooling line
CWA-2 / (CWW-2) UP TO 250’
of cooling line
CWA-34 / (CWW-34) UP TO 350’
of cooling line
CWA-100 UP TO 600’
of cooling line
(with 4 pumps)
CWA-175 UP TO 850’
of cooling line
(with 4
pumps)

DESCRIPTION
CWA-3 CWA-2 CWW-2 CWA-34 CWW-34
Voltage AC
120
120
120
208/230
208/230
Circuit Breaker 20 A, if 2nd
pump + 15 A
15 A +
1 pump 15 A or
2 pumps 20 A
15 A +
1 pump 15 A or
2 pumps 20 A
15 A +
1 pump 15 A or
2 pumps 20 A or
3 pumps 20 A + 15 A
15 A +
1 pump 15 A or
2 pumps 20 A or
3 pumps 20 A + 15 A
Plug (NEMA) 2 x 5-15P * 2 x 5-15P * 2 x 5-15P * 1 x 6-15P
1 x 5
-
15P *
1 x 6-15P
1 x 5
-
15P *
Running
8.1 A
10.5 A
9
.
2 A
6.5
A
5.
83 A
BTU
31
2
0
4
6
10
5
8
00
5
420
67
00
Refrigerant
R
-
134a
R
-
404a
R
-
404a
R
-
134a
R
-
404a
Charge
18
oz.
19
oz.
18
oz.
1
6 oz.
21
oz.
Tank Capacity
12 gal.
12 gal.
12 gal.
12 gal.
12 gal.
Foam insulation
1”
1”
1”
1”
1”
Weight
106 lb
113 lb
113 lb
134 lb
134 lb
Pressure
approximate
18 low
150 high
55 low
255 high
55 low
265 high
18 low
150 high
55 low
265 high
Pump
(Gravity Fed)
80 GPH
(Gear)
80 GPH
(Gear)
80 GPH
(Gear)
80 GPH
(Gear)
80 GPH
(Gear)
Dimensions
(inches)**
H: 29.0
W: 26.5
D: 17.0
H: 29.0
W: 26.5
D: 17.0
H: 29.0
W: 26.5
D: 17.0
H: 29.0
W: 26.5
D: 17.0
H: 29.0
W: 26.5
D: 17.0
* 1 extra plug 5-15P per additional pump. **Dimensions include pump and motor.

ECO-025 ECO-033 BVL-056 CMC-030 CMV-030
Voltage AC 120 120 120 120 120
Circuit Breaker 15 A 15 A 15 A 20 A 20 A
Plug (NEMA) 1 x 5-15P 1 x 5-15P 1 x 5-15P 2 x 5-15P 2 x 5-15P
Running 5.82 A 8.5 A 5.82 A 5.82 A
BTU 1875 2300 4140 2300 2300
Refrigerant R-134a R-134a R-134a R-134a R-134a
Charge 13 oz. 12 oz. 15 oz. 10 oz. 10 oz.
Tank Capacity 3 gal. 3 gal. 8 gal. 3 gal. 8 gal.
Foam insulation 0.5’’ 1” 0,5” 0,5” 0.5’’
Weight 60 lb 65 lb 95lb 97 lb 92 lb
Pressure
approximate
18 low
150 high
18 low
150 high
18 low
150 high
18 low
150 high
18 low
150 high
Pump
(Gravity Fed)
69 GPH
(Vertical)
69 GPH
(Vertical) None 50 GPH
(Pressure)
90 GPH
(Vertical)
Dimensions (inches)**
H: 11.0
W: 19.0
D: 16.5
H: 15.5
W: 20.0
D: 20.0
H: 15.0
W: 30.0
D: 16.25
H: 13.5
W: 27.5
D: 16.25
H: 29.15
W: 16.4
D: 16.4
**Dimensions include pump and motor.

CWA-100
2 pumps
CWA-100
3 pumps
CWA-100
4 pumps
CWA-175
2 pumps
CWA-175
3 pumps
CWA-175
4 pumps
Voltage AC
208/230
208/230
208/230
208/230
208/230
208/230
Circuit Breaker
20 A
20 A + 20 A
20 A + 20 A
20 A
20 A + 20 A
20 A + 20 A
Plug (NEMA) 1 x 6-20P
2 x 5
-
15P
1 x 6-20P
3 x 5
-
15P
1 x 6-20P
4 x 5
-
15P
1 x 6-20P
2 x 5
-
15P
1 x 6-20P
3 x 5
-
15P
1 x 6-20P
4 x 5
-
15P
Running
9.3 A
9.3 A
9.3 A
12.6 A
12.6 A
12.6 A
BTU
8,
4
30
8,
4
30
8,
4
30
1
2
,
1
00
1
2
,
1
00
1
2
,
1
00
Refrigerant
R
-
404a
R
-
404a
R
-
404a
R
-
404a
R
-
404a
R
-
404a
Charge
(se
e label on unit)
5 lb 5 lb 5 lb 6 lb 6 lb 6 lb
Tank Capacity
28
gal.
28
gal.
28
gal.
28
gal.
28
gal.
28
gal.
Foam insulation
1”
1”
1”
1”
1”
1”
Weight
257 lb
277 lb
297 lb
275 lb
295 lb
315 lb
Pressure
approximate
55 low
255 high
55 low
255 high
55 low
255 high
55 low
255 high
55 low
255 high
55 low
255 high
Pump
(Gravity Fed)
140 GPH
(pressure)
½ hp motor
140 GPH
(pressure)
½ hp motor
140 GPH
(pressure)
½ hp motor
140 GPH
(pressure)
½ hp motor
140 GPH
(pressure)
½ hp motor
140 GPH
(pressure)
½ hp motor
Dimensions
(inches)**
H: 34.0
W: 32.5
D: 27.5
H: 34.0
W: 38.5
D: 27.5
H: 34.0
W: 38.5
D: 27.5
H: 34.0
W: 32.5
D: 27.5
H: 34.0
W: 38.5
D: 27.5
H: 34.0
W: 38.5
D: 27.5
**Dimensions include pump and motor.

DRAWINGS
ECO-033 CWA CWW
Double/Triple Motor Bath Option, Used With CWA or CWW
Top view for CWA-3, CWA-2, CWA-34 (and also CWW units)
2 PUMPS 3 PUMPS
Triple/Quadruple Motor Bath Option, Used With CWA-100 and 175
Top view for CWA-100 and CWA-175
2 PUMPS 3 PUMPS 4 PUMPS

PRODUCT WARRANTY
BVL Controls warrants this product for one (1) full year including parts and labor
when unit is returned to our factory (freight is not part of the warranty) or parts only
when repair must be done at another location. Parts (under warranty) will be
charged to your account and will be credited upon receipt of the defective part.
In Canada: BVL Controls Ltd
661 de la Sabliere
Bois-des-Filion, Quebec, Canada
J6Z 4T2
Phone: 1-866-BVL-CONTROLS (285-2668)
Direct Line: (450) 965-0502
In U.S.A: Call us and we will refer you to the closest representative.
POWER PACK INFORMATION
(Please fill this form before contacting technical support)
Unit Information
Model Number
Serial Number
Product
ion Date
Compressor Number
Installation Date
Installed by (Company)

INSTRUCTIONS FOR THE INSTALLATION
ECO-025/ECO-033
1 : The supply voltage required for the unit is 120 VAC with a 15 A circuit breaker.
2 : For a proper functioning of the machine, leave a 6’’ (15 cm.) minimum clear space around
the condenser to facilitate air flow.
3 : Install a tube of cooling line at the output of the pump.
4 : Install the return of the same line at the input of the pump (to create a closed circuit).
5 : Remove the cover of the tank and pour 1 gallon (1 X 4 liters) of glycol 100% in the tank and
add water until just below the overflow.
Important: Never operate the pump before filling the tank.
The pump must always run to have a constant agitation in the tank and avoid damaging the
compressor.
6 : Replace the cover on top of the tank.
7 : Before plugging the power cord, ensure that the installation and connections have been made
to required specification. After any adjustments and making the electrical connection, start the
unit. The pump will start but take note there is a one minute delay before the unit start-up.
8 : The level of liquid in the tank will go down until the cooling line is filled.
9 : Unplug the pump, remove the cover and add water until just below the overflow.
10 : Replace the cover on top of the tank.
11 : Connect the pump.
12 : The temperature will slowly drop until 28⁰F (factory setting) on the thermostat display.

INSTRUCTIONS FOR THE INSTALLATION
CMC-030/CMV-030
1 : The supply voltage required for the unit and the pump is 120 VAC with a 20 A circuit
breaker.
2 : For a proper functioning of the machine, leave a 6’’ (15 cm.) minimum clear space around
the condenser to facilitate air flow.
3 : Install a tube of cooling line at the output of the pump.
4 : Install the return of the same line at the input of the tank (to create a closed circuit).
5 : Remove the cover of the unit and pour 1 gallon (1 X 4 liters) of glycol 100% in the tank for
the CMC-030 or 2 gallons (2 x 4 liters) for the CMV-030 and add water until just below the
overflow.
6 : Before plugging the pump, ensure that the installation and connections have been made to
required specification. After any adjustments, plug in the pump.
Important: Never operate the pump before filling the tank.
The pump must always run to have a constant agitation in the tank and avoid damaging the
compressor.
7 : The level of liquid in the tank will go down until the cooling line is filled.
8 : Add water until just below the overflow.
9 : Replace the cover on top of the unit.
10 : Switch on the unit. Note there is a one minute delay before the unit start-up.
11 : The temperature will slowly drop until 28⁰F (factory setting) on the thermostat display.

INSTRUCTIONS FOR THE INSTALLATION
CWA-2
1 : The supply voltage required for the unit is 120 VAC with a 15 A circuit breaker. If there is
one pump, provide an additional 15 A circuit breaker. If there are 2 pumps, provide instead an
additional 20 A circuit breaker.
2 : For a proper functioning of the machine, leave a 6’’ (15 cm.) minimum clear space around
the condenser to facilitate air flow.
3 : Install a tube of cooling line at the output of the pump.
4 : Install the return of the same line at the input of the tank (to create a closed circuit). Repeat
step 3 and 4 for each pump.
5 : Remove the unit from the top of the tank (always use the lifting handles to raise the unit) and
pour 3 gallons (3 X 4 liters) of glycol 100% in the tank and add water until just below the
overflow.
6 : Before plugging the pump(s), ensure that the installation and connections have been made to
required specification. After any adjustments, plug in the pump(s).
Important: Never operate the pump(s) before filling the tank.
The pump(s) must always run to have a constant agitation in the tank and avoid damaging the
compressor.
7 : The level of liquid in the tank will go down until the cooling line(s) is(are) filled.
8 : Add water until just below the overflow and replace the unit on top of the tank.
9 : Switch on the unit. Note there is a one minute delay before the unit start-up.
10 : The temperature will slowly drop until 28⁰F (factory setting) on the thermostat display.
Este manual sirve para los siguientes modelos