BV BV-BF-03-PLUS Guía

bathroom VENTILAtion fan
INSTALLatiON MANUAL and USER GUIDE
140 CFM: BV-BF-03-PLUS

CONTENTS
General Safety Information and Warnings .............................................................................
Included Parts ....................................................................................................................................
Dimensions ..........................................................................................................................................
Specications .....................................................................................................................................
Sizes .......................................................................................................................................................
Wiring Diagram .................................................................................................................................
Installation I (Joist Mounting) ......................................................................................................
Installation II (In Existing Construction) ...................................................................................
Maintenance ......................................................................................................................................
2
3
3
4
4
4
5
7
8

General safety information and warning
WARNING
2
Electrical service supply must be 120V 60Hz.
Follow all local building,safety and electrical codes as well as NEC(National Electrical Code) and OSHA
(Occupational Safety and Health Act).
This unit must be properly grounded.
Always disconnect the power supply prior to servicing the fan, motor or junction box.
Do not bend or kink the power wires.
Do not install where the room air temperature will exceed 104ºF (40ºC).
This ventilation fan is approved for use in a ceiling over a bathtub or shower when installed o n a ground-fault
circuit interrupter (GFCI) protected circuit. Do not use fan over a bathtub or shower that is not approved for
that application and marked accordingly.
Do not use to exhaust hazardous or explosive vapors.
Do not install in a cooking area.
Use this unit in the manner intended by the manufacturer. If you have any questions,please call customer service.
Installation work must be carried out by a qualifed person, in accordance to all local and safety codes, including
the rules for re-rated constructions.
Exercise care not to damage existing wiring when cutting or drilling into walls or ceilings.
Fans should always be vented to the exterior and in compliance with local codes. Do not vent exhaust air in
spaces within walls, ceiling, attic, crawl space or garage.
Do not use this fan with any solid state control device.
Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the power from
being turned on.
Duct work should be installed in a straight line with minimal bends.
Duct work size must be a minimum of the discharge and should not be reduced. Reducing the duct size can
increase fan noise.
The switch should not be accessible from inside of bathtub or shower.
The fan is to be mounted at least 7 feet (2.1 m) above the foor.
If this unit is to be installed over a tub or shower, it must be marked as a appropriate for the
application. When the fan is going to install in the bathroom, the fan and the tub need to be more than 1.0 meter
between each other, the fan required to install at the other side of the tub in ceiling. Acceptable for use over a
bathtub or shower when installed in a GFCI protected branch circuit.
The housing of ventilation fan NO: B-1
The wheel assembly of ventilation fan: B
Combine B-1 and B first,and then mounted to the ceiling.

INCLUDED PARTS
3
READ and SAVE THESE INSTRUCTIONS
Please read these instructions carefully before installing, operating or servicing the fan. Failure to comply with the
instructions contained herein could result in personal injury or property damage. We recommend that you keep this
guide for future reference.
CEILING
OPENING L
10 5/8”
(27 cm)
CEILING
OPENING W
10 5/8”
(27 cm)
CEILING
OPENING D
8 5/8”
(21.84 cm)
HOUSING
DIMENSION L
10 5/16”
(26.2 cm)
HOUSING
DIMENSION W
10 5/16”
(26.2 cm)
DIMENSIONS
Note: Be careful to cut the hope exactly because if it is too big, the grille will not hide it.
HOUSING
DIMENSION D
8 1/16”
(20.57 cm)
PART NAME APPERANCE QUANTITY
Grille
Long wood screws (4x30mm)
Short screws (4x6mm)
Suspension brackets I
Suspension brackets II
1
8
4
2
2

specifications
4
WIring diagram
MODEL
BV-BF-03-PLUS
AIR
DIRECTION HZ DUCT
DIAMETER
NOISE
(SONE) POWER AIR DELIVER
AT 0.1” WG
140 CFM 120 60 6”
(15.24 cm) 1.0 42 W 140 CFM
V
SIZES
FAN HOUSING
Capacitor for long
life of motor
Black wire
120 V AC 60 Hz
to switch
to neutral
to ground
White wire
Green wire
Junction box
Automatic terminal switch
Motor
13.38”
10.31”
8.07”
(20.57cm)
16” (40.64cm)
6” OUTLET
10.31”
8.86”
(22.5cm)
8.07”
(20.57cm)
16”(40.64cm)

INSTALLation I (joist mounting)
5
1. Insert the suspension bracket into the fan body. If spacing
between joists is 21 1/4” to 23 1/2” (54 cm to 59.7 cm) connect
suspension brackets I and II (Fig. 1).
2. Mount the fan body to joist using the suspension brackets and
long wood screws (Fig. 2-1 or Fig. 2-2 and 2-3).
CAUTION
Dimension “B” should allow for thickness of ceiling board
used in your application. Do not ush mount to joist. Flange
should be ush with ceiling board (Fig.2-1a)
2

INSTALLation I (joist mounting)
6
3. Refer to wiring diagram on page 4. Remove the junction box
cover. Using wire nuts, connect house wires to ventilating fan
wires: black to black; white to white; green to green. Replace
the junction box cover (Fig. 3).
CAUTION
If your house wires do not match these colors, you must
determine what each house wire represents before connect-
ing and you may need to consult an electrical contractor to
determine this safely. Mount junction box cover carefully so
lead wires are not pinched.
4. Install a circular dust and secure it with duct tape or clamps.
5. Finish ceiling work. Ceiling hole should be ush with the edge
of the ange. Do not ush mount to joist. Flange should be
ush with ceiling board. See dimension for ceiling hole on page 3
(Fig. 4). If a joist is present, insert long wood screws through ange
and through ceiling to secure fan to joist.
6. Pinch mounting springs and insert into narrow rectangular slots
inside the fan housing next to the fan motor (Fig. 5).
7. Turn on electricity at breaker box after nishing installation.
3

installation II (IN EXISTING CONSTRUCTION)
7
Installing the fan body in an existing building requires an accessible area (attic or crawl space) above the
planned installation location and existing duct and wiring.
A) To install the fan body, follow the procedures described in Installation I.
1. Take the following precautions before installation:
Check the area above installation location to be sure that:
Duct work can be run and the area is sufcient for proper ventilation;
Wiring can be run to the planned location;
No wiring or other obstructions can interfere with installation.
Inspect ductwork and wiring before proceeding with installation.
Plan suitable location for fan body (next to ceiling joist). Do not ush mount ange to ceiling joist.
Before installation, provide inspection and future maintenance access at al location that will not
interfere with installation work.
2. Remove ceiling section using dimensions provided on page 4. Be careful to cut the hole exactly.
If the hole is too big, the fan grille will not hide it.
3. Install fan body.
4. Continue with steps 3-7 of Installation I on page 6 to complete installation work.
B) Installation from accessible area (e.g. attic) above fan location:
1. Inspect duct work and wiring before proceeding with installation.
2. Remove ceiling section using dimensions provided on page 3.
3. Install fan body.
4. Continue with steps 3-7 of Installation I on page 6 to complete the installation work.

maintenance
8
ELECTRICAL WARNING
Disconnect power supply before servicing.
See General safety information and warnings on
page 5 before proceeding. Routine maintenance
should be done at least once a year.
CAUTION
- Never use solvents, thinner or harsh chemical
for cleaning the fan.
- Do not allow water to enter the motor.
- Do not immerse resin parts in water over 140°F
(60°C).
1. Remove grille by squeezing spring and pull down (Fig. 6).
2. Wash and clean the grille in a sink and dry with a cloth (Fig. 7)
3. Remove dust and dirt from the fan housing with
a vacuum cleaner (Fig. 8)
4. Dampen cloth with dish detergent, wipe the fan housing
and dry with a cloth (Fig. 9).
5. Replace the grille.
LIMITED WARRANTY
This is a quality product. It was made and selected with
care and BV offers a limited one-year warranty against
any manufacturing defects as long as it is used according
to its intended use. BV will exchange any product that
would show any such manufacturing defects.
However, this warranty does not include labor costs to
install or remove the fan.
STEP BY STEP MAINTENANCE