Bustec ProDAQ 3411 Manual de usuario

ProDAQ 3411
24-Ch. Enhanced ADC
Function Card
PUBLICATION NUMBER: 3411-XX-UM-0100
Copyright, © 1998-2009, Bustec Production, Ltd.
Bustec Production, Ltd.
World Aviation Park, Shannon, Co. Clare, Ireland
Tel: +353 (0) 61 707100, FAX: +353 (0) 61 707106
User Manual

PROPRIETARY NOTICE
This document and the technical data herein disclosed, are proprietary to Bustec
Production Ltd., and shall not, without express written permission of Bustec
Production Ltd, be used, in whole or in part to solicit quotations from a competitive
source or used for manufacture by anyone other than Bustec Production Ltd. The
information herein has been developed at private expense, and may only be used for
operation and maintenance reference purposes or for purposes of engineering
evaluation and incorporation into technical specifications and other documents,
which specify procurement of products from Bustec Production Ltd.. This document
is subject to change without further notification. Bustec Production Ltd. Reserve the
right to change both the hardware and software described herein.

ProDAQ 3411 24-Ch. ADC Function Card User Manual 3411-XX-UM
Copyright, 1998-2009 Bustec Production Ltd. Page 3 of 40
Table of Contents
1. Introduction _______________________________________________________7
2. Installation ________________________________________________________9
2.1.
Unpacking and Inspection _______________________________________________ 9
2.2.
Reshipment Instructions ________________________________________________ 9
2.3.
Preparing the ProDAQ Module___________________________________________ 10
2.4.
Installing a ProDAQ Function Card _______________________________________ 11
2.5.
Removing a ProDAQ Function Card ______________________________________ 13
3. Theory of Operation________________________________________________15
3.1.
General Description ___________________________________________________ 15
3.2.
Programmed Conversion _______________________________________________ 15
3.3.
Multiplexed Conversion ________________________________________________ 16
3.3.1.
Channel Mask _____________________________________________________ 16
3.3.2.
Scanning _________________________________________________________ 16
3.3.3.
Data Conversion____________________________________________________ 16
3.3.4.
The on-board FIFO _________________________________________________ 18
3.4.
Trigger ______________________________________________________________ 18
4. The VXIplug&play Driver____________________________________________19
4.1.
Installation ___________________________________________________________ 19
4.2.
The Soft Front Panel ___________________________________________________ 19
4.2.1.
Configuration ______________________________________________________ 20
4.2.2.
Data Acquisition ____________________________________________________ 21
4.2.3.
The Graph Controls _________________________________________________ 22
5. Programming the ProDAQ 3411 ______________________________________23
5.1.
Connecting to the Function Card ________________________________________ 23
5.2.
Setting Gain and Filter _________________________________________________ 24
5.3.
Acquiring single Samples_______________________________________________ 24
5.4.
Acquiring a Waveform _________________________________________________ 25
5.5.
Asynchronous Acquisition______________________________________________ 26
5.6.
Calibration ___________________________________________________________ 27
Appendix A: Front Panel Connector _____________________________________29
Appendix B: Register Description _______________________________________31
A.1
Address Map _________________________________________________________ 31
A.2
Detailed Register Description ___________________________________________ 32
A.1.1
FCID Register _____________________________________________________ 32
A.1.2
GCSR Register ____________________________________________________ 32
A.1.3
FCLEN Register ____________________________________________________ 33
A.1.4
OTRI Register _____________________________________________________ 33
A.1.5
ITRI Register ______________________________________________________ 34
A.1.6
DIVCLK Register ___________________________________________________ 34
A.1.7
MODE Register ____________________________________________________ 35

3411-XX-UM ProDAQ 3411 24-Ch. ADC Function Card User Manual
Page 4 of 40 Copyright, 1998-2009 Bustec Production Ltd.
A.1.8
REPCOUNT Register________________________________________________ 35
A.1.9
PATA Register _____________________________________________________ 35
A.1.10
PATB Register ___________________________________________________ 36
A.1.11
GAIFIL Register __________________________________________________ 36
Appendix C: Specifications ____________________________________________37

ProDAQ 3411 24-Ch. ADC Function Card User Manual 3411-XX-UM
Copyright, 1998-2009 Bustec Production Ltd. Page 5 of 40
Table of figures
Figure 1 - Removing the ProDAQ Module Cover______________________________________________ 10
Figure 2 - The ProDAQ Module Assembly ___________________________________________________ 12
Figure 3 - ProDAQ 3411 Block Diagram ___________________________________________________ 15
Figure 4 - Scan Timing __________________________________________________________________ 16
Figure 5 - Conversion Timing _____________________________________________________________ 17
Figure 6 - Multiple Channel Timing ________________________________________________________ 17
Figure 7 - Function Card Selection ________________________________________________________ 19
Figure 8 - ProDAQ 3411 Soft Front Panel User Interface_______________________________________ 20
Figure 9 - Front End Configuration Dialog __________________________________________________ 20
Figure 10 - Data Acquisition Configuration Dialog____________________________________________ 21
Figure 11 - Data Display ________________________________________________________________ 21
Figure 12 - Opening a Session ____________________________________________________________ 23
Figure 13 – Acquiring single Samples ______________________________________________________ 24
Figure 14 – Acquiring a Waveform_________________________________________________________ 25
Figure 15 – Starting the Asynchronous Acquisition ____________________________________________ 26

3411-XX-UM ProDAQ 3411 24-Ch. ADC Function Card User Manual
Page 6 of 40 Copyright, 1998-2009 Bustec Production Ltd.
Reference Documents
Title Number
ProDAQ 3120 Hardware Manual 3120-XX-HM
ProDAQ 3150 Hardware Manual 3150-XX-HM
Glossary
ADC Analog-to-Digital Converter
OTD Open Thermocouple Detection
MB Motherboard
FC Function Card

ProDAQ 3411 24-Ch. ADC Function Card User Manual 3411-XX-UM
Copyright, 1998-2009 Bustec Production Ltd. Page 7 of 40
1. Introduction
The ProDAQ 3411 Enhanced ADC function card provides 24 differential inputs with an input range
of up to ±10V. The channels are multiplexed into a gain and filter stage with a software selectable
gain of 1 to 1000 and three different filter settings to choose from. A 16-bit Analog-to-Digital
Converter sampling with 100 kHz converts the signal. The result can be used directly or buffered in
an on-board FIFO for asynchronous operation.
For calibration, the internal ground as well as the voltage reference bus from the ProDAQ
motherboard can be included in the measurement as a 25
th
and 26
th
channel.
The ProDAQ 3411 function card is one of a range of function cards designed to provide full
functionality when installed in one of the range of ProDAQ motherboard modules such as the
ProDAQ 3120.

3411-XX-UM ProDAQ 3411 24-Ch. ADC Function Card User Manual
Page 8 of 40 Copyright, 1998-2009 Bustec Production Ltd.

ProDAQ 3411 24-Ch. ADC Function Card User Manual 3411-XX-UM
Copyright, 1998-2009 Bustec Production Ltd. Page 9 of 40
2. Installation
2.1. Unpacking and Inspection
The ProDAQ module is shipped in an antistatic package to prevent any damage from electrostatic
discharge (ESD). Proper ESD handling procedures must always be used when packing, unpacking
or installing any ProDAQ module, ProDAQ plug-in module or ProDAQ function card:
•Ground yourself via a grounding strap or similar, e.g. by holding to a grounded object.
•Discharge the package by touching it to a grounded object, e.g. a metal part of your VXIbus
chassis, before removing the module from the package.
•Remove the ProDAQ module from its carton, preserving the factory packaging as much as
possible.
•Inspect the ProDAQ module for any defect or damage. Immediately notify the carrier if any
damage is apparent.
2.2. Reshipment Instructions
Use the original packing material when returning a ProDAQ module to Bustec Production Ltd. or
calibration or servicing. The original shipping carton and the instrument's plastic foam will provide
the necessary support for safe reshipment.
If the original anti-static packing material is unavailable, wrap the ProDAQ module in anti-static
plastic sheeting and use plastic spray foam to surround and protect the instrument. Reship in either
the original or a new shipping carton.

3411-XX-UM ProDAQ 3411 24-Ch. ADC Function Card User Manual
Page 10 of 40 Copyright, 1998-2009 Bustec Production Ltd.
2.3. Preparing the ProDAQ Module
To install a ProDAQ Function Card into one of the ProDAQ Motherboards, you need to remove the
modules top cover:
1 - Module Cover 2 - Cover Screws 3 - Cover Hooks
Figure 1 - Removing the ProDAQ Module Cover
To remove the top cover, remove the one countersunk screw in the back and the two panhead
screws towards the front panel (), that hold the cover in place. Remove the cover by sliding it out
of its position towards the VXIbus connectors and up. Take special care about the hooks ()
holding it into place. Try not to lift the cover straight up. See Figure 1 for the location of the screws.
To re-install the cover, slide it back into its position by placing the small hooks over their holes and
moving the cover down and forward. Secure the top cover using the two panhead screws and one
countersunk screw ().