Brunner BKH 5.0 flat 42-50 green Manual de usuario

Installation Manual
BKH 5.0 flat
42-50
©2023

CONTENTS
1 Basic informations..................................................................................................... 3
2 Safety precautions..................................................................................................... 3
3 Specified symbols......................................................................................................4
4 Delivery contents BKH 42-50 flat............................................................................. 6
4.1 Catalytic converter (optional)........................................................................................................ 9
4.2 Heat protection panel (optional)..................................................................................................10
4.3 Heat exchanger rings (optional)..................................................................................................11
4.4 Air connection box (optional)...................................................................................................... 11
5 Safety distances BKH flat....................................................................................... 12
6 Setting up.................................................................................................................. 14
6.1 Remove the transport locks........................................................................................................ 14
6.2 Heat protection panel (optional)..................................................................................................15
6.3 Set up the fireplace.....................................................................................................................26
6.4 Variant with external combustion air connection........................................................................ 28
6.4.1 Bottom connection (B).................................................................................................. 30
6.4.2 Side connection (S)...................................................................................................... 36
6.5 Variant with EAS or EOS............................................................................................................42
7 Fitting: catalytic converter...................................................................................... 53
8 Fitting: deflection - combustion chamber............................................................. 57
9 Variants heat exchanger..........................................................................................66
9.1 Connection with catalytic converter............................................................................................ 66
9.2 Connection without catalytic converter....................................................................................... 67
9.3 Cast iron dome............................................................................................................................73
9.4 Heat exchanger rings.................................................................................................................. 75
9.5 Heat exchanger MAS.................................................................................................................. 81
10 Frame variants..........................................................................................................87
10.1 Door frame (BKH with side-opening door)..................................................................................87
10.2 Mounting frame or door frame (BKH with lifting door)................................................................88
11 Conversions, settings.............................................................................................. 93
11.1 Change of the door stop............................................................................................................. 93
11.2 Adjusting of self-closing door.................................................................................................... 109
11.3 Modification - lifting door: “non self closing”............................................................................. 117
12 Disposal...................................................................................................................120
13 Technical data........................................................................................................ 122
2 Installation Manual BKH 5.0 flat 42-50 green (1.13) © 2023 Brunner GmbH

1 BASIC INFORMATIONS
All instructions delivered with products must be observed. We do not accept any warranty claim or
liability for damage resulting from failure to observe these installation instructions!
Improper installation can cause injury and material damage!
The floor space of the room must have a suitable structure and sufficient dimensions to ensure proper func-
tioning of the fireplace.
Please note that other installation and assembly instructions are included in other packaging units!
Dimensioning of downstream heat accumulator must be according to valid stove-setting rules.
During installation of the fireplace, all dimensions and minimal clearances of the fireplace casing must be
held as specified by the manufacturer.
All binding national or EU standards and local regulations for the installation of fireplaces must be observed.
All valid stove fitting rules and regulations of local construction law must be observed and followed.
Please follow the relevant regulations of your country.
When these instructions are followed and all works are done properly, this will ensure a safe, energy-sav-
ing and environmentally friendly operation of the stove. Pictures shown are not to be considered as complete
representations of any kind.
Subject to technical and assortment changes.
Please notify your supplier of any damage which might have occurred during transport.
Please keep these instructions.
Please also take note of the online product documentation provided
by:
General instructions of the Brunner products installation for the
stove construction.
(https://www.brunner.de/produktdownloads/kacheloefen-kamine/allge-
meine-hinweise-fuer-den-aufbau_de.pdf) laden können.
2 SAFETY PRECAUTIONS
Fireplaces may be set up only in rooms or areas with no risk of danger due to their location, structure or in-
tended use.
Working on the stove Installation, commissioning, servicing and maintenance works on the
product may be carried out only by an authorized stove-fitter. Safety
and efficiency of the system depend on this!
Working with electronics Switch off the emergency switch or circuit breaker, and secure them
against switching on again.
© 2023 Brunner GmbH Installation Manual BKH 5.0 flat 42-50 green (1.13) 3

Fireplaces with external air supply are not independent from room air supply and must be consid-
ered and designed as roomsealed fireplaces. In connection with a ventilation or extraction system,
we recommend the use of a negative pressure safety device (Art.No.: 11600.1).
Installation must be carried out by an authorized stove-fitter, because safety and efficiency of the system de-
pend mostly on proper installation of the product. All valid stove fitting rules and regulations of building law
must be observed and followed. Make sure to instruct the owner or user about the functions and controls of
the system and possibly installed safety devices.
Fireplaces must be built to ensure safe operation and fire safety in order to eliminate possible risks and un-
acceptable loads. They have to be ready for use over an adequate period of time.
Make sure to instruct the owner or user about the functions and controls of the system and possibly installed
safety devices.
Remember to use only genuine replacement parts.
3 SPECIFIED SYMBOLS
In this documentation, a distinction is made between:
Operating personnel as the User of the system, i.e. the end user, which has received instructions from the Contractor
and does not necessarily have additional qualifications.
Operating personnel as the Contractor, i.e. the qualified professionals, which are entitled to perform the indicated spe-
cialist works.
In this document, the following symbols are used:
DANGER
A danger of high risk persists, which leads to severe injury or death, if this endangering situa-
tion is not avoided.
WARNING
A danger of medium risk persists, which can lead to severe injury or death, if this endangering
situation is not avoided.
CAUTION
A danger of low risk persists, which can lead to minor or moderate injury, if this endangering
situation is not avoided.
ATTENTION
There is a certain risk, which can lead to a malfunction or damage of the related system and all
devices connected with it, if the indicated notifications are not followed.
4 Installation Manual BKH 5.0 flat 42-50 green (1.13) © 2023 Brunner GmbH

NOTE
Additional helpful information
© 2023 Brunner GmbH Installation Manual BKH 5.0 flat 42-50 green (1.13) 5

4 DELIVERY CONTENTS BKH 42-50 FLAT
Available variants with lifting door (ST):
BKH 42-50 flat with lifting door
9.2 9.1 8.2
6.4
3
1
4
5
8.1
6.1
6.2
7
6.1 6.3
2
6 Installation Manual BKH 5.0 flat 42-50 green (1.13) © 2023 Brunner GmbH

Available variants with side-opening door (DT)
BKH 42-50 flat with side-opening door (DT)
8.1
8.2
3
1
7
4
6.2
6.1 6.4
6.2
6.1
5
2
9.1
© 2023 Brunner GmbH Installation Manual BKH 5.0 flat 42-50 green (1.13) 7

Art.-Nr.
Pos. Designation
for ST for DT
BKH - variants:
BKH 5.0 Flach 42-50 ST with manual operation, with Ceram-
ic glass (GK) chamotte inner linging (FR) HK003002-01 -
BKH 5.0 Flach 42-50 ST with manual operation, with Glass
ceramic coated (GKB) chamotte inner linging (FR) HK003002-05 -
BKH 5.0 Flach 42-50 ST for EAS/EOS with Ceramic glass
(GK) chamotte inner linging (FR) HK003002-02 -
BKH 5.0 Flach 42-50 ST for EAS/EOS with Glass ceramic
coated (GKB) chamotte inner linging (FR) HK003002-06 -
BKH 5.0 Flach 42-50 ST with manual operation, with Ceram-
ic glass (GK) Cast iron inner lining (FR/Guss) HK003002-03 -
BKH 5.0 Flach 42-50 ST with manual operation, with Glass
ceramic coated (GKB) Cast iron inner lining (FR/Guss) HK003002-07 -
BKH 5.0 Flach 42-50 ST for EAS/EOS with Ceramic glass
(GK) Cast iron inner lining (FR/Guss) HK003002-04 -
BKH 5.0 Flach 42-50 ST for EAS/EOS with Glass ceramic
coated (GKB) Cast iron inner lining (FR/Guss) HK003002-08 -
BKH 5.0 Flach 42-50 DT with manual operation, with Ceram-
ic glass (GK) chamotte inner linging (FR) - HK002002-01
BKH 5.0 Flach 42-50 DT with manual operation, with Glass
ceramic coated (GKB) chamotte inner linging (FR) - HK002002-05
BKH 5.0 Flach 42-50 DT for EAS/EOS with Ceramic glass
(GK) chamotte inner linging (FR) - HK002002-02
BKH 5.0 Flach 42-50 DT for EAS/EOS with Glass ceramic
coated (GKB) chamotte inner linging (FR) - HK002002-06
BKH 5.0 Flach 42-50 DT with manual operation, with Ceram-
ic glass (GK) Cast iron inner lining (FR/Guss) - HK002002-03
BKH 5.0 Flach 42-50 DT with manual operation, with Glass
ceramic coated (GKB) Cast iron inner lining (FR/Guss) - HK002002-07
BKH 5.0 Flach 42-50 DT for EAS/EOS with Ceramic glass
(GK) Cast iron inner lining (FR/Guss) - HK002002-04
1
BKH 5.0 Flach 42-50 DT for EAS/EOS with Glass ceramic
coated (GKB) Cast iron inner lining (FR/Guss) - HK002002-08
2The non-installed parts (e.g. deflection plates, control levers, etc.) and any accessories ordered (e.g. catalytic
converter, packaging with EOS, etc.), including the instructions box, are packed in the combustion chamber
verbaute Combustion chamber lining:
- aus Chamotte
3
- aus Cast iron
4 Ceramic glass (GK)
5 Catalyst module BKH 5.0 HK000210
Smoke hood variants
8 Installation Manual BKH 5.0 flat 42-50 green (1.13) © 2023 Brunner GmbH

Art.-Nr.
Pos. Designation
for ST for DT
Rotating cast iron dome with adjustable connecting piece ⌀
180 mm D004186
6.1
Rotating cast iron dome with connecting piece d=200 mm 10087
6.2 with heat exchanger rings R015006-02
6.3 Connection variant MAS SET440 SET211444
6.4 Cast iron dome low D016042
Additional options
7 Heat protection panel see Variants “Heat protection panel”
Supply air connection box ⌀ 125 mm HK000135
8.1
Supply air connection box ⌀ 150 mm HK000136
8.2 Supply air connection box ⌀ 125 mm with EOS / EAS HK000080
9.1 Door frame, black HK003152-01 HK002150-01
9.2 Mounting frame, black HK003150-01 -
4.1 CATALYTIC CONVERTER (OPTIONAL)
The catalytic converters are coated with a catalytically ac-
tive layer. This coating can consist of mixed metal oxides
or also of precious metals. In order not to limit the effect
of this catalytically active layer, the catalysts may only be
handled with gloves, preferably with disposable gloves.
In order not to limit the effect of this catalytically active lay-
er, the catalysts may only be handled with gloves, prefer-
ably with disposable gloves.
.
ATTENTION
The catalysts are fragile and must only be handled with care. Avoid bumping and
do not drop the catalytic converter. This could destroy the catalytic converter!
© 2023 Brunner GmbH Installation Manual BKH 5.0 flat 42-50 green (1.13) 9

1
2
1 catalytic converter
2 assembly tool
Note
This catalytic converter is suitable for all BKH units (with lifting door, with side opening
door, tunnel, with cast dome, with heat exchanger cast rings and MAS).
This catalytic converter can also be retrofitted.
4.2 HEAT PROTECTION PANEL (OPTIONAL)
2
1
2
1 HK004450 Heat protection panel backwall,
incl. screws
2 HK00251 Heat protection panel, side,
incl. mounting frame, screws
HK004450-01 = HK004450(1) + 1x HK00251 (2)
HK004450-02 = HK004450(1) + 2x HK00251 (2)
10 Installation Manual BKH 5.0 flat 42-50 green (1.13) © 2023 Brunner GmbH
Tabla de contenidos
Otros manuales de Chimenea de interior de Brunner

Brunner
Brunner KSO Manual de usuario

Brunner
Brunner BKH Manual de usuario

Brunner
Brunner BKH 5.0 flat 50-98 green Manual de usuario

Brunner
Brunner Iron dog 06 Manual de usuario

Brunner
Brunner green BKH 5.0 50-82 Manual de usuario

Brunner
Brunner Panorama Manual de usuario

Brunner
Brunner I048145 Manual de usuario

Brunner
Brunner green BKH 5.0 50-98 Manual de usuario

Brunner
Brunner BKH 5.0 flat 42-98 green Manual de usuario

Brunner
Brunner BKH 5.0 flat 42-66 green Manual de usuario