Contents
1. Introduction ………………….…………………………….……..………….
p2
2. Caution…………………………………………………….………………….…..
p2
3. Delivery control …………………………………………........................
p3
4. Technical description ……………………….…………………………..
p3
Technical characteristics
Outside
Inside
Explored view
Wire control operation
General diagram of the refrigerating circuit
Safety and control systems
Electric diagram
5. Installation ……………………….………………………………….......
p13
Rules of installation
Hydraulic connections
Electric connections
Procedure of use
6. Water flow and refrigerating circuit pressure........................
p17
7. Defrosting ……………………………………………………………………
p18
8. Environment problem ………………………………………............
p19
9. Error messages and what to do ………………………………..…
p19

2
1-
Introduction
We thank you for having chosen our Heat pump.
This installation and maintenance notice contains the necessary
information to its installation (delivery control, the installation, the
connections) and to its repair. It is a complementary document to the
user’s manual which describes its instructions for use.
We invite you to read it first.
2-
Caution
This document is an integral part of the product and it must stay in the
technical room.
This Heat pump is exclusively for heating swimming pools.
Any other use not in conformity and random will be considered as
dangerous and unsuitable.
The assembly, the electric connection and the start up must be carried
out by specialized and professional person.
When connect to socket (power supply), please make sure that live wire,
neutral wire, earth wire is right.
It is essential to maintain the temperature in the swimming pool lower
than the recommended value by the swimming pool’s manufacturer.
Please make sure that minimum water flow speed is 7m³/h.
In a concern to a constant improvement, our products can be modified
without notice; the present pictures in this note or the characteristics
which are described are not contractual.

3
3- Delivery’s control
At the delivery time, check the condition of packing; in case of damages,
have reservation about them to the carrier, before 48 hours and by
registered letter with acknowledged receipt.
Before any manipulation, check the complete state of the machine.
4
-
Technical description
Characteristics:
UnitModel Unit BP‐90HS‐SIEIP BP‐110HS‐SIEIP BP‐130HS‐SIEIP
HeatingCapacity
A26/W26 kW 9.0~2.3 11.0~2.85 13.0~4.0
COP A26/W26 W/W 6.0~13.8 6.0~13.8 5.9~13.6
HeatingCapacity
A15/W26 kW 6.4~1.7 7.7~2.05 9.3~2.8
COP A15/W26 W/W 4.6~7.1 4.6~7.1 4.50~7.0
CoolingCapacity
A35/W28 kW 4.3~1.0 5.3~1.5 6.2~2.3
PowerInput kW 1.6~0.24 2.0~0.29 2.45~0.36
Current A 7.5~1.1 9.3~1.5 10.7~2.2
PowerSupply V/P/Hz 220/1/50 220/1/50 220/1/50
CompressorQty 1 1 1
HeatingExchanger TitaniuminPVC
WaterConnection mm 50 50 50
Noise1m dB(A) 38~48 39~49 41~52
Noise10m dB(A) 19~29 20~30 21~31
WaterFlowVolume m3/h 4 5 6
Refrigerant(R32) g 500 550 650
Co2weightofthe
fluorinatedgreenhouse
gases
T 0.34 0.37 0.44
NetUnitSize(L/W/H) mm 880x310x600 880x310x600 1020x370x715
CartonSize(L/W/H) mm 940x410x635 940x410x635 1080x470x750
Net/GrossWeight kg 52/58 56/62 61/69
*
possible variations of value according to climatic conditions

4
Outside:
Inside:
(Front sheet cover and panel removed)
1 Fanprotectiongrid
2Frontpanel
3 Topcover
4 Controlpanel
5 Refrigerant pressuremanometer
6 Fastconnectionforwateroutlet
7 Fastconnectionforwaterintlet
8 Wireconnectionforpowersupply
9 Evaporator
10 Fan
11 Compressor
12 Highandlowpressureinterruptor
13 Titaniumheatexchanger
14 Temperaturesensorofswimmingpoolwater
15 Fourwayvalve
16 Ambienttemperaturesensor
17 Defrostsensor
18 Waterflowswitch

5

6
Wire control operation
Wire controller operation
Functions of Buttons
“ ” button
If the machine is on, press this button to turn it off.
If the machine is off, press this button to turn it on. And the TSET will be shown for 5S. Then it will
show the inlet water temperature and working mode. (System will keep the working mode. If no,
the default working mode is Smart mode under Heating.)
During parameter checking or setting, press this button will return to default interface. (The
parameter checking setting will be saved.) Press this button again will turn the machine off.
“MODE”button
Press “M” button 3 seconds to convert modes.
Press this button to check and set parameters, With the function of “▲”“▼”buttons, you can
check current run parameters 1~F.
NO Meanin
g
Ran
g
e Remarks
1 Inlet water temperature -50 ~ 99°C Measured value
2 Outlet water temperature -50 ~ 99°C Measured value
3 Outdoor ambient temperature -50 ~ 99°C Measured value
4 Exhaust gas sensor temperature 0 ~ 150°C Measured value
5 Return gas sensor temperature -50 ~ 150°C Measured value
6 Heating coil sensor temperature -50 ~ 150°C Measured value
7 Cooling coil sensor temperature -50 ~ 150°C Measured value
8 Main EEV steps 80 ~ 480 Measured value
9 Auxiliary EEV steps 150 ~ 480 Measured value
A Current of compressor 0 ~ 30A Measured value
b Module temperature 50 ~ 150°C Measured value
C DC bus voltage value Measured value
d Running frequency of compressor 20 ~ 90Hz Measured value
E Rotation speed of fan 1 0 ~ 1599(rpm) Measured value
F Rotation speed of fan 2 0 ~ 1599(rpm) Measured value

7
“▲”“▼”button
TSET setting and Lock/Unlock the screen
TSET setting: Press “▲”/“▼”button, raise or reduce the TSET 1℃ by 1℃.
Lock/Unlock the screen:Press “▲”and“▼”button 3 seconds, to set keylock; Press “▲”
and“▼”button 3 seconds again to release keylock.
“TIME”button
Press “TIME” button for 3s to enter clock setting. With the function of “▲”“▼”buttons, you
can set hour first. Then press “TIME” button again, minute setting will be available。
Press “TIME” button to enter the timer setting. Press “ ” button to set the Timer Switch ON,
Change the hour using the “ ” and “ ” key. Press “ ” button again to change the
minutes using the “ ” and “ ” key; Press “ ” button again to set the Timer Switch OFF,
Change the hour using the “ ” and “ ” key. Press “ ” button again to change the
minutes using the “ ” and “ ” key, Press “ ” button again the display returns to normal.
“” and “ ” light up.
The timer setting is from 0 to 24 hours to recycle.
When the setting timer for on and off is the same,the setting timer is not available.
When the setting timer(displayed blinks), Press “MODE” to deactivate TIMER.
“SMART”Mode
Press "Smart" button to enter smart mode, the machine runs in smart mode.
“POWER”Mode
In heating mode, press "Power" button to enter power mode, the machine runs in power mode.
“SILENT”Mode
Press "Silent" button to enter silent mode, the machine runs in silent mode.
Coercive Defrosting
Press “MODE” and“▼”button 5S when unit is heat mode, the unit go to defrost state,
When fulfilled defrost stop conditions, defrost is stopped.
Symbol explanation
Run light : light on during running
Heating light: light on during heating mode. Heating light flash means defrosting.
Cooling light: light on during cooling mode
AUTO light: light on during auto mode
Timing boot light: light on if timing boot function is enabled.
Timing boot light flash means timing boot checking or setting.
Timing shutdown light: light on if timing shutdown function is enabled.
Timing shutdown light flash means timing shutdown checking or setting.

8
Light on under smart mode, machine working with the standard frequency.
Light on under power mode, machine working with the high powers.
Light on under silent mode, machine working with the low frequency.

9
General diagram of the refrigerating circuit
The heat pump is reversible allowing the swimming-pool’s heating or
cooling:
Swimming-pool water’s heating mode:
The cold and liquid refrigerant fluid absorbs the heat contained in the air through the evaporator (gilled
radiator), in which it is vaporizing; it is then put up in pressure and in temperature by the compressor
which sends it in the condenser (exchanger) where it loses its heat (in giving it to the water of
swimming pool) and comes back in liquid state; it loses its pressure and still cools in the expansion
valve before turning back to the evaporator for a new cycle.
Evaporator
(gilled
Hot air
radiator) Electronic
expansion
valve
Cold air
Pressure and gas
intake
4 way valve
Hotwater
Compressor Condenser
(exchanger)
Cold water
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Bomba de calor de Bridge
Manuales populares de Bomba de calor de otras marcas

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manual de usuario

Dimplex
Dimplex LI 16I-TUR Guía del usuario

Carrier
Carrier WSHP Open v3 Guía de configuración rápida

TGM
TGM CTV14CN018A Manual de usuario

Carrier
Carrier 38MGQ Series Manual de usuario

Kokido
Kokido K2O K880BX/EU Guía de solución de problemas

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Guía rápida

Carrier
Carrier 48EZN Manual de usuario

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Instrucciones de funcionamiento

Ariston
Ariston NIMBUS Manual de usuario

Weishaupt
Weishaupt WWP L 7 Guía del usuario

GE
GE Zoneline AZ85H09EAC Manual de usuario