CAUTION: DO NOT INSTALL THIS PRODUCT UNTIL YOU READ
AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN PERSONAL INJURY, PROPERTY
DAMAGE OR PRODUCT FAILURE.
The Safety+PLUS®gas connector combines two state-of-the-
art technologies for a safer installation for your home and family.
Safety+PLUS®gas connectors feature ProCoat®, a coating specially
engineered to resist the corrosion from harsh chemicals found in
most household cleaning and plumbing repair products. Approved
for indoor and outdoor use, ProCoat®is also formulated to resist the
harsh effect of UV rays & salt.
The Safety+PLUS®excess ow valve bypass (EFVB), an automatic
safety valve for gas. In the event of a gas line rupture or
disconnection at the appliance, the Safety+PLUS®valve immediately
restricts gas ow to a non-hazardous level (a bypass ow) to avert
the potential for a dangerous release of gas into the home. Only
after the gas line has been properly repaired, the bypass ow
automatically resets the valve, resuming gas ow to the appliance.
INSTALLATION INSTRUCTIONS
APPLICATION:
•
Use only on low pressure natural and LP gas piping systems. DO NOT USE on
pipelines or piping systems that transfer or move liquids, including high-pressure
liquid petroleum.
•
Use only with gas line pressures at a minimum of .5 in. water column (W.C.) and
not greater than
1/2 psig. (14 in. W.C.)
at the stub out.
•
Use only in connection with residential and commercial gas appliances,
not subject to frequent movement, where the EFV in installed immediately
downstream of the gas supply stub out and manual gas shut-off valve.
TOOLS NEEDED FOR INSTALLATION
• (2) 10 in. adjustable wrenches • Leak detection solution
• Pipe thread sealant • Wire brush & rag
SIZING THE CONNECTOR FOR
YOUR APPLIANCE
1.
Measure the distance between the gas
supply stub out and the appliance pulled
away from the stub out at it’s maximum
distance. Add 2 – 3 in. to the measured
distance for appropriate connector
length for the installation. (See Fig. A)
Gas Connectors
With Safety+PLUS®Excess Flow Valve
2.
Identify the maximum (gas) input
rating of the appliance (referred to
as “input rating”). Manufacturer’s
label, located near the gas inlet of the
appliance will contain this information.
(See Fig. B) Contact the appliance
manufacturer if you are unsure of the
correct rating for the appliance.
3. Select the Safety+PLUS®gas
connector with the capacity closest to
but GREATER THAN the input rating of
the appliance (Figure C)
WARNING:
With the Safety+PLUS
valve, the maximum gas input rating
of the appliance must be within
the ow capacity range of the gas
connector. If the Safety+PLUS gas
connector is not properly sized to
the application, the Safety+PLUS
connector may not activate in
the event of a gas line rupture or
disconnect. If the Safety+PLUS gas
connector is undersized for the
appliance, it may activate prematurely
restricting gas ow during normal
operation of the appliance.
4.
Finally, select the connector with the
end ttings that match the outlet of your
manual gas shut-off valve and the gas inlet to the appliance. (Figure D)
Chart 1
Gas Connector Maximum Flow Capacity
Part # ID
Color Code 12 in 18 in 24 in 30 in 36 in 48 in 60 in 72 in
Gas Connector with Standard Fittings
CSSL
1/4 BTU’s 48,000 43,800 40,000 36,400 33,400 28,300 24,900 23,100
Purple Watts 14,067 12,837 11,723 10,668 9,789 8,294 7,297 6,770
CSSD
3/8 BTU’s 102,000 93,100 85,000 77,100 71,100 60,500 53,200 49,100
Green Watts 29,893 27,285 24,911 22,596 20,837 17,731 15,591 14,390
CSSC
1/2 BTU’s 180,000 164,200 150,000 136,000 125,000 106,000 93,200 86,000
Gold Watts 52,752 48,122 43,961 39,858 36,634 31,066 27,314 25,204
Safety+Plus® (Gas Connector with Excess Flow Valve Attached)
CSSL
1/4 BTU’s 42,000* 37,400* 36,800* 36,400 33,400 28,300 24,900 23,100
Purple Watts 12,308* 10,960* 10,784* 10,668 9,789 8,294 7,297 6,770
CSSD
3/8 BTU’s 102,000 93,100 85,000 77,100 71,100 60,500 53,200 49,100
Green Watts 29,893 27,285 24,911 22,596 20,837 17,731 15,591 14,390
CSSC
1/2 BTU’s 122,000* 118,000* 115,000* 111,000* 107,000* 106,000 93,200 86,000
Gold Watts 35,754* 34,581* 33,702* 32,530* 31,358* 31,066 27,314 25,204
*Note: Connecting the safety valve lowers these values below the Z21.24/CSA 6.10 and Z21.75/CSA 6.27 standards
Listings & Certications:
Components CSA listed to ANSI Z21.24 / CSA 6.10 standard “Connectors for
Gas Appliances”
Components CSA listed to ANSI Z21.75 / CSA 6.27 standard “Connectors for
Outdoor Gas Appliances & Manufactured Homes”
NOTE: This connector meets or exceeds the minimum allowable capacity as
determined under test conditions specified in ANSI Z21.24 • CSA 6.10. Straight
length capacity rated in BTU per hr. using: 0.64 SP. Gr., 1000 BTU per Cu Ft. Gas
at 0.50 inch Water Column Pressure Drop. The capacity at 50 Pa (0.2 inch water
column) pressure drop can be determined by multiplying the BTU per hr. listed
in the table above by 0.632
.
CONNECTOR
CAPACITY
36"
33,400
63,000
104,000
71,100
GAS APPLIANCE
INPUT RATING
62,500
CONNECTOR
CAPACITY
36"
33,400
63,000
104,000
71,100
GAS APPLIANCE
INPUT RATING
62,500
CONNECTOR
CAPACITY
36"
33,400
63,000
104,000
71,100
GAS APPLIANCE
INPUT RATING
62,500
Fig. B
Fig. C
Fig. D
* Massachusetts State Plumbing Code Mandates a maximum
connector length of 48 IN. or 4 FT.
* 6 FT. Maximum
GAS SUPPLY PIPE
Tubo de suministro de gas
MANUAL SHUT-OFF VALV E
Vavula manual para cerrar el gas
SAFETY+PLUS APPLIANCE EFV
Valvula Safety+PLUS para exceso de ujo
GAS CONNECTOR
FLARE NUT
Tuerca abocinado del
conector de gas
GAS FLOW
Flujo de gas
Figure A