Boulevard DVLL48BP92N-1 Guía de inicio rápido

INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
DIRECT VENT ZERO CLEARANCE
GAS FIREPLACE HEATER
MODEL SERIES:
MULTIFUNCTION REMOTE (MF)
DVLL48BP92(N,P)-1
DVLL60BP90(N,P)-1
GAS-FIRED
UL FILE NO. MH30033
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certied kit is
used.
WARNING
If not installed, operated and maintained
in accordance with the manufacturer’s
instructions, this product could expose
you to substances in fuel or from fuel
combustion which can cause death or
serious illness.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
— Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
— Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HOT GLASS
DO NOT TOUCH
NEVER
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
NOTE: Barrier required, may be sold separately.

36459-6-0217Page 2
BEFORE YOU START
SAMPLE WARNINGS AND DEFINITIONS:
DANGER
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTICE: Addresses practices not related to personal injury.
1. Read the safety information on pages 57 - 58.
2. If located in the Commonwealth of Massachusetts, please
note the special requirements on page 59.
3. Areyougoingtoinstallablowerintothereplace?See
pages 8 - 10.
4. Whereareyougoingtoinstallthereplace?Seepage13.
5. Frametheopening.Seepage20.
6. Installthegaslines.Seepages16-17.
7. Installthewiring.Seepages18-19.
8. Installtheventing.Seepages24-33.
9. Installthereplace.Seepages20-23.
10. Installtheremotesystem.Seepages38-45.
11. Linerrequirements.Seepage36.
12. Installtheglassmedia.Seepage37.
13. Lightthereplaceandtroubleshoot.Seepages46-48.
14. Showthehomeownerhowtooperatethereplace.
15. Showthehomeownerhowtodothebasicmaintenance.
UNPACKING THE FIREPLACE
1. Cut binding straps and shrink wrap.
2. Remove top board and corner posts.
3. Liftreplaceoffofthepallet.
4. Remove non-combustible boards from pallet and set aside.
5. Verifythatthereplaceandcomponentshavenotbeen
damaged during shipping.
6. Setreplaceinalocationneartoitsnalinstallationlocation.
INSTALLATION CONSIDERATIONS - FIREPLACE
INSTALLATION GUIDELINES
Whenplanningareplaceinstallation,it’snecessaryto
determine:
• Gassupplypiping(rightsideentrance).
• Electricalsupplyrequirements
(120V,60Hz,1Amp)(rightsideentrance)
• DVLL60BPmodelsincludethefactoryinstalledAccentLight
assembly.TheDVLL48BPmodelsdonotincludetheAccent
Lightassembly.However,theLK20AccentLightKitmaybe
purchasedandinstalledduringorafterreplaceinstallation.
Instructions are supplied with the Accent Light kit.
• Properopeningsizeofframingrequiredforinstallationof
thereplace.Theframingofthereplacewilldeterminehow
thereplacenishingmaterialswillbeapplied.Refertothe
installation information pages 20 to 23.
• Theblowerkitiseasiertoinstallatthetimeofreplace
installations.Seeblowerinstallationsectiononpages8to
10.
Inplanningtheinstallationforthereplace,determinewherethe
replaceistobeinstalledandwhetheroptionalaccessoriesare
desired.Gassupplypipingshouldalsobeplannedatthistime.
Thereplacecanbemountedonanyofthesesurfaces:
1. Aathardcombustibleornon-combustiblesurface.
2. A raised platform of combustible or non-combustible
material.
Ifthereplaceisinstalleddirectlyoncarpeting,tileorother
combustiblematerialotherthanwoodooring,itshouldbe
installed on a metal or wood panel extending the full width and
depthofthereplace.
Thereplaceisdesignedtobeinstalledinazero-clearance
enclosure. This means that combustible materials must be
locatedatclearancesspeciedorprovidedbystandoffsor
spacersattachedtothereplace.
Combustible materials can come in contact with the nailing
angesprovided.
HOMEOWNER REFERENCE INFORMATION
Recordthefollowinginformationaboutyourreplace.
Model: ____________________________________ Datepurchased/installed: _________________
SerialNumber: _____________________________ Locationonreplace: ____________________
Dealership: ________________________________ DealerPhone: _________________________
Notes: ______________________________________________________________________________
____________________________________________________________________________________

36459-6-0217 Page 3
CARTON CONTENTS & HARDWARE PACK
1
2
3
6
5
7
4
8
10
9
11
12
1” PHILLIPS SELF DRILLING SCREW
#10 X ½” HEX HEAD SCREW
NAILING FLANGES
Items not shown to scale.
INDEX
NUMBER DESCRIPTION QUANTITY
SUPPLIED
1DoorRemovalTool(attachedto
replace) 1
2 Product Registration Card 1
3 AA Battery 4
4 AAA Battery 3
5WallThimbleSpacer(attachedto
replace) 1
6 Cover Plate, Battery Box 1
7 Remote 1
8 Junction Box Cover 1
9DuplexReceptacle 1
10 Flue Restrictor Assembly 1
11 Battery Box 1
12 Grommet,5/8DIA 1
A#10x1/2Screw 22
B#8x1Self-DrillingScrew* 15
CNailingFlange 4
*Foruseinmountingnon-combustibleboardtostandoffs.
SeePartsListsonpages50fororderingreplacementparts.Do
not order batteries, bolts, screws, washers or nuts. They are
standard hardware items and can be purchased at any local
hardware store.
A
B
C

36459-6-0217Page 4
TABLE OF CONTENTS
INTRODUCTION .................................................................................................... 5
SPECIFICATIONS .................................................................................................. 6
ACCESSORIES ...................................................................................................... 7
FBB20BLOWERINSTALLATION ................................................................... 8 - 10
FIREPLACEDIMENSIONS ...................................................................................11
CLEARANCES...................................................................................................... 12
LOCATINGFIREPLACE....................................................................................... 13
VENTTERMINATIONCLEARANCES........................................................... 14 - 15
GASSUPPLY................................................................................................. 16 - 17
ELECTRICALCONNECTIONS ..................................................................... 18 - 19
INSTALLATION.............................................................................................. 20 - 23
VENTSYSTEMIDENTIFICATION ....................................................................... 24
VENTSYSTEMS .................................................................................................. 24
VENTINGFIREPLACE-TOP........................................................................ 25 - 27
TOPVENT-HORIZONTALTERMINATION......................................................... 28
TOPVENT-VERTICALTERMINATION .............................................................. 29
VERTICALTERMINATION ............................................................................ 30 - 31
DVVK-5FFLEXVENTINSTRUCTIONS ....................................................... 32 - 33
FRAMINGANDFINISHING........................................................................... 34 - 35
LINERINSTALLATION ......................................................................................... 36
GLASSPLACEMENT ........................................................................................... 37
MULTIFUNCTIONREMOTEOPERATINGINSTRUCTIONS........................ 38 - 45
CONTROLSYSTEMTROUBLESHOOTING................................................. 46 - 47
LIGHTINGINSTRUCTIONS ................................................................................. 48
PARTSVIEW ........................................................................................................ 50
PARTSLIST.......................................................................................................... 51
COMPONENTWIRINGDIAGRAM ...................................................................... 52
MAINTENANCEANDSERVICE.................................................................... 53 - 56
IMPORTANTSAFETYINFORMATION ......................................................... 57 - 58
SAFETYINFORMATIONFORUSERSOFLPGAS ............................................ 59
REQUIREMENTSFORMASSACHUSETTS ....................................................... 60
FIREPLACESERVICEHISTORY ........................................................................ 61
MASTERPARTSDISTRIBUTORLIST ................................................................ 62
HOWTOORDERREPAIRPARTS....................................................................... 62
WARRANTY.......................................................................................................... 63
SECTION PAGE

36459-6-0217 Page 5
Instructions to Installer
1. Leave instruction manual with owner.
2. HaveownerlloutandmailProductRegistrationCard
suppliedwiththereplace.
3. Showownerhowtostartandoperatethereplace.
Thisdirect-ventgasreplaceheaterisdesignedtooperatewith
all combustion air being siphoned from the outside of the building
and all exhaust gases expelled to the outside of the building. The
information contained in this manual pertains to all models and
gas control systems unless otherwise noted.
Appliance Certication
WARNING
This replace is not for use with solid fuels. Solid fuels
could cause personal injury or property damage.
ThisreplaceisdesigncertiedinaccordancewithAmerican
NationalStandard/CSAStandardANSIZ21.88/CSA2.33andby
UnderwritersLaboratoriesasaDirectVentGasFireplaceHeater
and shall be installed according to these instructions.
Consult your local building code agency, prior to installation,
to ensure compliance with local codes-including permits and
inspections.
Thereplace,wheninstalled,mustbeelectricallygroundedin
accordance with local codes or, in absence of local codes, with
the National Electric Code ANSI/NFPA 70orCanadianElectric
code,CSAC22.1,ifanexternalelectricalsourceisutilized.
These models may be installed in a bedroom or bed-sitting room
intheU.S.A.andCanada.
Qualied Installing Agency
Installationandreplacementofgaspiping,gasutilization
equipment or accessories and repair and servicing of equipment
shallbeperformedonlybyaqualiedagency.Theterm“qualied
agency”meansanyindividual,rm,corporationorcompany
which either in person or through a representative is engaged
inandisresponsiblefor(a)theinstallationorreplacementof
gaspipingor(b)theconnection,installation,repairorservicing
of equipment, who is experienced in such work, familiar with all
precautions required and has complied with all the requirements
of the authority having jurisdiction.
Commonwealth of Massachusetts: The installation must be
madebyalicensedplumberorgastterintheCommonwealth
of Massachusetts.
WARNING
ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS
CAN BE DANGEROUS.
Improper installation or use of the replace can cause
serious injury or death from re, burns, explosions, or
carbon monoxide poisoning.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code ANSI Z223.1/
NFPA 54* Natural Gas and Propane Installation Code, or CSA
B149.1 in Canada. *Available from the American National
Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
AllcorrespondenceshouldrefertocompleteModelNumber,
SerialNumberandtypeofgas.
High Altitude
Wheninstallingthisreplaceatanelevationabove2000feet
(intheUnitedStates)itmaybenecessarytodecreasetheinput
ratingbychangingtheexistingburneroricetoasmallersize.
Generally,inputshouldbereduced4percentforeach1000
feetabovesealevel.However,iftheheatingvalueofthegas
has been reduced, this general rule may not apply. Check with
EmpireComfortSystemsforproperoricesizeidentication.
Canadian High Altitude
Altitude:0-4500feet(0-1370m)
Wheninstallingthisreplaceatanelevationabove4500feet(in
Canada),checkwithEmpireComfortSystemsforassistancein
determiningtheproperoriceforlocation.
Preparation
Thisdirectventgasreplaceanditscomponentsaretestedand
safe when installed in accordance with this installation manual.
Reporttoyourdealeranypartsdamagedinshipment,specically
checkglasscondition.Donotinstallreplacewithdamaged,
incomplete, or substitute parts. Read all instructions before
starting installation and follow these instructions carefully during
installationtoinsuremaximumbenetandsafety.Failureto
followthemwillvoidyourwarrantyandmaypresentarehazard.
The warranty will be voided by, and the warranter disclaims any
responsibility for the following actions:
• Installationofanydamagedreplaceorventsystem
component.
• Modicationofthereplaceordirectventsystem.
• InstallationotherthanasinstructedbyEmpireComfort
SystemsInc.
• Improperpositioningoftheglassdoor,ordecorative
accessories including logs, rocks, crushed glass or other
approved media.
• Installationand/oruseofanycomponentpartnot
manufactured or approved by manufacturer.
INTRODUCTION

36459-6-0217Page 6
SPECIFICATIONS
DVLL48BP DVLL60BP
NAT LP NAT LP
InputBTU/HrMaximum 38,000 34,000 46,000 42,500
InputBTU/HrMinimum 25,000 27,000 31,000 32,500
KWH(Maximum) 11.13 9.95 13.34 12.33
KWH(Minimum) 7.32 7.90 9.00 9.43
Orice #31 #50 #29(P280) #48(P300)
AirShutterOpening 1/16-in FullyOpen 1/16-in FullyOpen
Heightwithoutstandoff 34-5/16 34-5/16 36-5/16-in 36-5/16-in
Width 69-in 69-in 73-in 73-in
Depth 18-5/8-in 18-5/8-in 18-5/8-in 18-5/8-in
GasInletShutoffValve
(pipe)
1/2-inNPT 1/2-inNPT 1/2-inNPT 1/2-inNPT
VentSize 5 x 8 5 x 8 5 x 8 5 x 8
NOTE: Airshuttersettingsarefactoryminimumsettings.Someventingcongurationsmayrequireminorairshutteradjustmentsfor
optimum performance.
GAS SUPPLY PRESSURES
(dimensions in inches water column - w.c.)
GAS TYPE MAXIMUM MINIMUM MANIFOLD
NAT 14 4.5 3.5
LP 14 11 10

36459-6-0217 Page 7
ACCESSORIES
Description Accessory Model # Color
Fireplace Models DVLL48BP DVLL60BP
RidgebackLiner* DVP48LPZ DVP60LPZ Bronze
PorcelainLiner* DVP48LKR DVP60LKR GlossBlack
TrimKit-Beveled DF48BL DF60BL Black
TrimKit-Beveled DF48HP DF60HP HammeredPewter
Beveled Window Frame - 2 inches DF482NB DF602NB NickelBrushed
DecorativeFront,ForgedIron DFF48FPD DFF60FPD DistressedPewter
RusticContemporaryLogs&Stones LS48THF LS60THF N/A
AccentLightKit LK8 N/A N/A
ConversionKit-LPtoNAT 36435 35470 N/A
ConversionKit-NATtoLP 36434 35469 N/A
*DVLL60BPmodelsrequireeitheraRidgebackLineroraPorcelainLiner.TheDVLL48BPreplaceisshippedwithafactoryinstalled
metalliner.Ifdesired,itcanbereplacedwithoneoftheotherlineroptions.Thereplacemusthavealinerinstalledpriortooperation.
**NOTE:Iftheoptionalblowerkitisdesired,installationintothereplacethroughtherearaccesspaneliseasier,priortoplacingthe
replaceintotheframedoutlocation.
Forapplicationandtheamountofcrushedglasstouse,refertothe“GlassPlacement”sectiononpage37.
ThefollowingaccessorypartscanbeobtainedfromyourEmpireComfortSystemsdealer.ContactyourEmpireDealerformore
accessoryoptions.Ifyouneedadditionalinformationbeyondwhatyourdealercanfurnish,contactEmpireComfortSystemsInc.,918
Freeburg Ave., Belleville, Illinois 62220-2623.
ACCESSORIES

36459-6-0217Page 8
FBB20 BLOWER INSTALLATION
1
1
2
BLOWER ASSEMBLY PARTS LIST
INDEX
NO.
PART
NO DESCRIPTION QTY
1 35727 BlowerAssembly-Single 2
2 R11788 WireHarness 1
TOOLS NEEDED:
5/16inNutdriverorscrewgun
CAUTION
Sharp edges. Use gloves when installing these blowers.
Installation - Prior to Setting Fireplace Into Final Position
1. UnpacktheFBB20Blowerassembly.
2. Usinga5/16inhexdrive,removethe11screwsholdingrear
blower access cover plate, then lay the access plate on the
oor.See Figure 1.
Figure 1
3. Usearagtowipetheinsidebottomofthereplace(where
theblowerswillbeplaced)toremovedirtorconstruction
dust.
4. Placeblowersontheoorbehindthereplace.Position
the blowers with the two black connecting wires and green
ground wire towards the left hand side when facing the back
ofthereplace.See Figure 2.
Figure 2
5. Locate the blower wire terminals inside the bottom of the
replaceandmakethethreeconnectionsasshowninFigure
3.
Figure 3

36459-6-0217 Page 9
FBB20 BLOWER INSTALLATION
6. Begin installing the left blower assembly into the bottom of
thereplace.Oncetheblowerisabouthalfwayin,secure
wiring within the white plastic wire retention clips provided in
thereplace.See Figure 4.
Figure 4
7. Finish installing the left blower so that the left edge of the
blower base bracket is about even with the left edge of the
access opening. Route the wiring away from the blower
wheel. See Figure 5.
Figure 5
8. Next,installtherighthandblowerassemblytowardsthe
right side of the access opening. The right hand edge of the
blower base bracket should be about even with the right
edge of the access opening. Route wiring away from the
blower wheel. See Figure 6.
Figure 6
9. Snapthewireharnessintothewhiteplasticwireretention
cliplocatedatthecenterbottomofthereplace.See Figure
7.
Figure 7

36459-6-0217Page 10
FBB20 BLOWER INSTALLATION
10. Make sure the blower base brackets are pulled rearward
againstthebottomangeofthereplace.Themagnetson
the blower base bracket will keep the blowers in place. See
Figure 8.
Figure 8
11. Re-attach the Blower Access Panel with the 11 screws
removed in step 2. See Figure 1.
12. Blower installation is complete.
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Chimenea de interior de Boulevard

Boulevard
Boulevard LS60THF-1 DVLL60BP90N-1 Guía de inicio rápido

Boulevard
Boulevard VFLL60SP90LN-1 Manual de usuario

Boulevard
Boulevard VFLL72FP90LN-1 Guía de inicio rápido

Boulevard
Boulevard DVLL41FP92N-1 Guía de inicio rápido

Boulevard
Boulevard VFLL60SP90LP-1 Manual de usuario

Boulevard
Boulevard LS60THF-1 DVLL60BP90N-1 Guía de inicio rápido

Boulevard
Boulevard DVLL48SP90N-1 Guía de inicio rápido

Boulevard
Boulevard VFLL60FP90LN-1 Guía de inicio rápido

Boulevard
Boulevard VFLB60SP90-1 Manual de usuario

Boulevard
Boulevard DVLL48NAT Guía de inicio rápido