Bosch MIC 612 Series Manual de usuario

MIC612 Thermal Camera
MIC612
en Operation Manual


Table of contents
1Safety 5
1.1 About this Manual 5
1.2 Legal Information 5
1.3 Safety Precautions 5
1.4 Important Safety Instructions 5
1.5 Customer Support and Service 7
2Unpacking 8
2.1 Parts List 8
2.2 Additional Products Required 8
2.3 Additional Tools Required 9
3Product Description 10
4Electrical Connections 11
4.1 About the MIC Shielded Composite Cable 11
4.2 Composite Cable Color-coding 12
5Install the MIC (standard) PSU 14
5.1 MIC PSU Overview 14
5.2 About the MIC Shielded Composite Cable 14
5.3 Composite Cable Color-coding 15
5.4 Earth Link on PCB 16
5.5 Fuse Ratings 17
5.6 Alarm Inputs 17
5.7 Layout of MIC Power Supply Units (PSUs) 17
5.8 Installation Warnings and Prerequisites 19
5.9 Installation Instructions (Power Supply) 20
5.10 Commissioning the Camera with Heater Option Fitted 28
5.11 Simultaneous IP and Analog Video/Control ("Hybrid" Operation) 30
6Fit the Sunshield (MIC612) 31
7Getting Started 33
7.1 Establishing Control of the Camera 33
7.1.1 Establishing Control of the Camera via Biphase Protocol 33
7.1.2 Establishing Control of the Camera via RS-485 Protocol 33
7.2 Powering On 34
7.3 About Setting the Camera Address via FastAddress 34
7.4 Setting the Addresses of the Two Cameras of the MIC612 35
7.5 FastAddress, Bosch Protocol 35
7.6 FastAddress, Pelco Protocols 36
7.7 Active Commands in FastAddress 37
7.8 Setting Passwords 37
7.8.1 Special Passwords 37
7.8.2 Setting Passwords, Bosch Protocol 37
8Controlling the Camera 38
8.1 Basic Keyboard Operation 38
8.2 Navigating the On-Screen Display (OSD) Menus 38
8.3 Keyboard Commands, Bosch Protocol 39
8.4 Keyboard Commands, Pelco Protocol 39
8.5 Special Preset Commands, Pelco Protocol 40
MIC612 Thermal Camera Table of Contents | en 3
Bosch Security Systems Operation Manual 2016.03 | 2.2 | F.01U.249.416

9On-Screen Display (OSD) Menus (Bosch Protocol) 42
9.1 Camera Setup Menu 44
9.2 Thermal Camera Setup Menu 46
9.3 Lens Setup Menu 48
9.4 PTZ Setup Menu 50
9.5 Display Setup Menu 52
9.6 Communication Setup Menu 54
9.7 Alarm Setup 55
9.8 Language Menu 61
9.9 Diagnostics Menu 62
10 On-Screen Display (OSD) Menus (Pelco Protocol) 66
10.1 Bosch Menu 68
10.2 Camera Setup 69
10.3 PTZ Setup 70
10.4 AUX Setup Menu 72
10.5 Other Menus 73
11 Operation of the Thermal Camera 74
11.1 Switching Video 74
11.2 Flat-Field Correction (FFC) 74
11.3 Displaying Thermal Camera Temperature 74
11.4 Triggering Alarms On Detection of Objects Outside of Set Thermal Temperature
Threshold
75
12 Common User Commands 76
12.1 Configuring Preposition Tours 76
12.2 Recording Tours 76
12.3 Using the Wiper/Washer (Bosch Protocol) 77
13 Advanced Features 78
13.1 Alarm Rules 78
13.1.1 Controlling Alarm Rules 78
13.1.2 Alarm Rule Examples 78
13.2 Pre-position Tour 79
13.3 Privacy Masking 79
13.4 Image Stabilization 80
13.5 Azimuth, Elevation, and Compass Directions 80
13.5.1 Setting the Azimuth Zero Point 81
13.5.2 Displaying Azimuth, Elevation, and Compass Headings 81
14 Maintenance and Troubleshooting 82
15 Technical data 85
16 Appendices 86
16.1 Keyboard Commands (Bosch Protocol) By Number 86
16.1.1 Commands, Optical Camera 86
16.1.2 Commands, Thermal Camera 89
4en | Table of Contents MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems

Safety
About this Manual
This manual has been compiled with great care and the information it contains has been
thoroughly verified. The text was complete and correct at the time of printing. Because of the
ongoing development of products, the content of the manual may change without notice.
Bosch Security Systems accepts no liability for damage resulting directly or indirectly from
faults, incompleteness, or discrepancies between the manual and the product described.
Legal Information
Copyright
This manual is the intellectual property of Bosch Security Systems, Inc. and is protected by
copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
Safety Precautions
In this manual, the following symbols and notations are used to draw attention to special
situations:
Danger!
High risk: This symbol indicates an imminently hazardous situation such as “Dangerous
Voltage” inside the product. If not avoided, this will result in an electrical shock, serious bodily
injury, or death.
!
Warning!
Medium risk: Indicates a potentially hazardous situation. If not avoided, this may result in
minor or moderate injury.
!
Caution!
Low risk: Indicates a potentially hazardous situation. If not avoided, this may result in
property damage or risk of damage to the unit.
Notice!
This symbol indicates information or a company policy that relates directly or indirectly to the
safety of personnel or protection of property.
Important Safety Instructions
Read, follow, and retain all of the following safety instructions. Heed all warnings on the unit
and in the operating instructions before operation.
1
1.1
1.2
1.3
1.4
MIC612 Thermal Camera Safety | en 5
Bosch Security Systems Operation Manual 2016.03 | 2.2 | F.01U.249.416

!
Caution!
TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT THE POWER SUPPLY BEFORE
OPENING THE POWER SUPPLY UNIT.
POWER DISCONNECT: POWER SUPPLY UNITS HAVE POWER SUPPLIED WHENEVER THE
POWER CORD IS INSERTED INTO THE POWER SOURCE.
!
Warning!
INSTALLATION SHOULD BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY, IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, ANSI/NFPA, CANADIAN ELECTRICAL
CODE, AND ALL LOCAL COUNTRY CODES.
!
Warning!
INSTALL EXTERNAL INTERCONNECTING CABLES IN ACCORDANCE TO NEC, ANSI/NFPA70
(FOR US APPLICATION) AND CANADIAN ELECTRICAL CODE, PART I, CSA C22.1 (FOR CAN
APPLICATION) AND IN ACCORDANCE TO LOCAL COUNTRY CODES FOR ALL OTHER
COUNTRIES. BRANCH CIRCUIT PROTECTION INCORPORATING A 20 A, 2-POLE LISTED
CIRCUIT BREAKER OR BRANCH RATED FUSES ARE REQUIRED AS PART OF THE BUILDING
INSTALLATION. A READILY ACCESSIBLE 2-POLE DISCONNECT DEVICE WITH A CONTACT
SEPARATION OF AT LEAST 3 mm MUST BE INCORPORATED.
!
Warning!
ROUTING OF EXTERNAL WIRING MUST BE DONE THROUGH A PERMANENTLY EARTHED
METAL CONDUIT.
!
Warning!
THE CAMERA MUST BE MOUNTED DIRECTLY AND PERMANENTLY TO A NON-COMBUSTIBLE
SURFACE.
– Do not place a canted (45°) camera upright; it can fall over easily. Place the canted
camera on its side.
– Do not open the camera unit. Doing so will invalidate the warranty.
– Ensure that the unit case is properly earthed. If the product is likely to be struck by
lightning, ensure that earth bonding connections are made correctly to the mounting of
the base of the unit.
– Do not point the camera at the sun. Bosch Security Systems will not be liable for any
damage to cameras that have been pointed directly at the sun.
– Do not manually back drive the pan or tilt axis of the camera. Doing so will damage the
motor drive gear train and will invalidate the warranty.
– Before transporting, power on the camera and rotate the ball so that the window points
toward the base. This will help to protect the wiper and the window during transit.
6en | Safety MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems

Customer Support and Service
If this unit needs service, contact the nearest Bosch Security Systems Service Center for
authorization to return and shipping instructions.
Service Centers
USA
Telephone: 800-366-2283 or 585-340-4162
Fax: 800-366-1329
Email: [email protected]
Customer Service
Telephone: 888-289-0096
Fax: 585-223-9180
Email: [email protected]
Technical Support
Telephone: 800-326-1450
Fax: 585-223-3508 or 717-735-6560
Email: [email protected]
Repair Center
Telephone: 585-421-4220
Fax: 585-223-9180 or 717-735-6561
Email: [email protected]
Canada
Telephone: 514-738-2434
Fax: 514-738-8480
Europe, Middle East & Africa Region
Please contact your local distributor or Bosch sales office. Use this link:
http://www.boschsecurity.com/startpage/html/europe.htm
Asia Pacific Region
Please contact your local distributor or Bosch sales office. Use this link:
http://www.boschsecurity.com/startpage/html/asia_pacific.htm
More Information
For more information please contact the nearest Bosch Security Systems location or visit
www.boschsecurity.com
1.5
MIC612 Thermal Camera Safety | en 7
Bosch Security Systems Operation Manual 2016.03 | 2.2 | F.01U.249.416

Unpacking
– This equipment should be unpacked and handled with care. Check the exterior of the
packaging for visible damage. If an item appears to have been damaged in shipment,
notify the shipper immediately.
– Verify that all the parts listed in the Parts List below are included. If any items are
missing, notify your Bosch Security Systems Sales or Customer Service Representative.
– Do not use this product if any component appears to be damaged. Please contact Bosch
Security Systems in the event of damaged goods.
– The original packing carton is the safest container in which to transport the unit and must
be used if returning the unit for service. Save it for possible future use.
!
Caution!
Take extra care lifting or moving MIC612 cameras because of their weight (10.66 kg (23.5
lb)).
Parts List
Quantity Part
1 MIC550 Camera
1 Installation Manual
4 M8 stainless screws and washers
1 Nebar gasket
Quantity Part
1 MIC550IR Camera
1 Installation Manual
4 M8 stainless screws and washers
1 Nebar gasket
Quantity Part
1 MIC612 Camera
1 Installation Manual
4 M8 stainless screws and washers
1 Nebar gasket
Additional Products Required
Mounting accessories are sold separately by Bosch. (Refer to the chapter Product Description
for a list.) Users must supply all wiring/cabling for power, video, and telemetry.
The following table lists additional products, sold separately by Bosch, required to operate
each MIC camera:
2
2.1
2.2
8en | Unpacking MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems

Quantity Product Part Number Size
1 per camera
Shielded Composite Cable for MIC612 cameras
(See the model numbers and lengths at right.)
MIC-THERCBL-2M 2 m
MIC-THERCBL-10M 10 m
MIC-THERCBL-20M 20 m
MIC-THERCBL-20M 25 m
Quantity Product Part Number
1 per camera Power Supply Unit (PSU) for MIC cameras
MIC-240PSU-2,
MIC-115PSU-2,
MIC-24PSU-2
Additional Tools Required
The following table lists additional tools (not supplied by Bosch) that are or may be required
to install a MIC camera:
Quantity Part
1 13 mm wrench for the mounting bolts
1 3 mm screwdriver for the terminal blocks in the MIC PSU
1 8 mm screwdriver for captive screws for the MIC PSU enclosure
1 Silicone sealant for ensuring a water tight seal [if not using the Nebar gasket]
1 Roll of PTFE tape
2.3
MIC612 Thermal Camera Unpacking | en 9
Bosch Security Systems Operation Manual 2016.03 | 2.2 | F.01U.249.416

Product Description
MIC Series 612 cameras are high-performance, weatherproof, ruggedized, fully functional day/
night PTZ cameras that have been designed to offer a reliable, robust, and high-quality
surveillance solution for extreme security applications.
MIC612 models have a 36x optical zoom (12x digital) and flexible mounting options (upright
or inverted) to achieve the perfect field of view.
Precision-engineered to exacting standards, MIC cameras offer numerous benefits over
traditional dome and PTZ cameras. Rated to an industry-leading IP68, the compact, vandal-
resistant, cast aluminum camera housing is pre-treated and then painted with polyester
powder coat paint (black, white, or grey). Brushless motor technology ensures ultra-reliable
operation with full 360° continuous pan and up to 320° tilt control. The optically perfect, flat
viewing window and integrated wiper ensure that razor-sharp images are captured in even the
most demanding environmental conditions.
A long-life silicone wiper blade mounted on a spring-loaded arm is standard on all MIC
cameras.
The following table identifies the optional accessories for MIC cameras. Refer to the
datasheets of each accessory for details. Some accessories may not be available in all regions.
Accessories Description
MIC-DCA Deep Conduit Adapter
MIC-SCA Shallow Conduit Adapter
MIC-CMB Corner Mount Bracket
MIC-PMB Pole Mount Bracket
MIC-WMB Wall Mount Bracket
MIC-SPR Spreader Plate
MIC-ALM Alarm and washer pump drive card for non-IR PSU; 8 inputs.
MIC-WKT Washer kit, containing mounting bracket, nozzle, and washer pump drive card.
MIC-BP4 Bosch Biphase converter card for MIC power supplies with an available
expansion slot.
MIC412SUNSHIELD
A two-part plastic sunshield to provide additional protection in sunny climates
for MIC cameras Comes with stainless steel bosses, washers, and retaining
screws.
3
10 en | Product Description MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems
Otros manuales para MIC 612 Series
4
Tabla de contenidos
Otros manuales de Cámara térmica de Bosch

Bosch
Bosch MIC 612 Series Manual de usuario

Bosch
Bosch Professional GIS 500 Manual de usuario

Bosch
Bosch MIC412TIBUP13636N Manual de usuario

Bosch
Bosch GTC 400 C Professional Manual de usuario

Bosch
Bosch MIC 612 Series Manual de usuario

Bosch
Bosch GTC 400 C Instrucciones de montaje

Bosch
Bosch MIC 612 Series Manual de usuario

Bosch
Bosch GTC 400 C Professional Manual de usuario

Bosch
Bosch GTC 400 C Professional Manual de usuario

Bosch
Bosch MIC 612 Series Manual de usuario