A range of compact water dispensers, available in four different operational types:
• Chilled & Ambient
• Chilled, Ambient & Sparkling
• Chilled, Ambient & Hot
• Chilled, Hot & Sparkling
All Models
All models are self-contained machineswith robust
steel framed cabinets and attractively injection
moulded plastic front, side and top panels. There
is
sufficient space internally for most filters to be fitted
behind the door panel. An IEC Power Lead is
supplied for connection to the IEC socket found on
the rear of all models (An additional
Schuko type is supplied for the European
market).
The level control system also incorporates a leak
detection device within the cabinet which isolates
the water to the unit in the event of detecting a
water leak.
Chilled
The cold temperature is thermostatically controlled
via the adjustment screw on the back of the
machine. This is factory set and is not necessary to
adjust in most cases (see Controls).
Ambient
Water bypasses the cold tank for the ambient
dispense option.
Sparkling
Water is chilled as it passes through the coil
immediately before dispense or being pumped
under pressure into the carbonator which it fitted
inside the
same coil. The carbonator is also level controlled
and allows the sparkling effect to occur through
saturation with CO2.
Hot
The hot water is provided by hot water tank with
an integrated heater element. The water is
supplied directly into the tank under the pressure as
connected
into the back of the unit. The water fills the tank
and hot water is dispensed. The water flow is
controlled by a solenoid.
Unite, DC15:
Release date 13.05.2018
B5 Install & Operation
Manual
Introduction
Controls
Cold Thermostat
Model Overview

This shows the correct and factory default set
point. Although adjustment is possible (clockwise
reduces the temperature and anti-clockwise
increases the
water temperature), this correct default setting is to
ensure optimum performance and reliability.
Unauthorised alternative settings could cause
technical issues and invalidate the warranty.
Chilled
On/Off Switch: at upper rear of machine,
switches cooling operation on/off.
Cold Thermostat: at rear of machine.
Cold Button: press to dispense cold water.
Green LED (Top): Colours to show cooling
operation is switched on.
Green LED (Bottom): Colours to show when
compressor is operating/water is above set point.
10A Fuse: On rear of machine, integral with IEC
socket.
Ambient
Ambient Button: Press to dispense ambient water.
Sparkling
Soda: Switches sparkling operation on/off.
Sparkling Button: Press to dispense sparkling water
Yellow LED (bottom RH): Colours to show the
sparkling operation is switched on.
Hot
On/Off Switch: The hot water heating mode is
controlled by a switch on the back of the unit, next
to the cooling mode switch. This switch is labelled
“Hot”.
Hot Thermostat: regulated by a pre-set,
nonadjustable sensor on the tank.
Hot Button: press to dispense hot water.
Lock Button: toggles on and off the dispense of hot
water.
Red LED (on hot water icon): Colours to show
heating mode is enabled.
Red LED (marked heating): Colours to show
heating element is active according to thermostatic
demand.
Storage Cabinet

All models are fitted with a lower storage area.
The door panel is hinged and fastened with
magnetic catches. There is a removable cover
protecting the machine parts.
Every DC15 is supplied with a level sensor kit,
comprising:
• Water container
• Level sensor module

Attach the regulator to the
disposable CO2 bottle,
ensuring the regulator is closed.
Connect the assembled CO2
bottle and regulator to the
machine using 1/4 inch pipe.
After completing the water
installation, turn on the soda
power switch and the pump will
run. Do not open the regulator
valve until the carbonated
switch has been turned on.
We recommend between 3.5 –
5 bar. Do not exceed 5 bar
pressure.
Flush through approximately 10
litres of water. Check and adjust
the CO2 pressure accordingly.
It will be necessary to leave the
machine for up to 1 hour for
sparkling water to develop, by
absorbing the CO2.
IMPORTANT! ALWAYS ENSURE SECURITY CLIPS ARE USED ON ALL WATER AND CO2
CONNECTIONS.
Level Sensor Assembly

Check all parts are present. Locate and connect the drainage tubing into the
top of the level sensor connector.
The LED lighting at the base of the faucet will flash
slowly for 1 minute. This is also repeated every
time a
dispense button is pressed.
Empty the waste container to cancel.
A WARNING TONE WILL SOUND WHEN THE WATER RISES. UPON EMPTYING THE CONTAINER
THE WARNING TONE WILL STOP.

Connect and turn on the water
supply.
Plug in the power supply, cold,
hot & sparkling tanks will
automatically fill.
Activate the carbonation & hot
power switch (if present).
Activate cold power switch. Flush through 10 litres of water
before use.
When the cold water switch is
turned on, the cold water and
chilling LED will be on.
Water Connection & Operation
Operation

The temperature of cold water can be set from 4c
to 10c.
When the chilling LED is off the set temperature
has been reached. This can take up to one hour.
When the heating LED is off the pre-set temperature
has been reached. This can take up to 30mins.
Functions & Controls
General Safety


Please make sure the machine is completely
disconnected from electricity before carrying out
any maintenance work.
Turn off the water supply.
To drain the Direct Chill tank, remove the caps on the back of the machine. We recommend it is refitted
immediately upon draining being completed.
Isolation & Removal
Maintenance