Boltek LRX-1 Instrucciones de funcionamiento originales

LRX1ANT50-020819
BOLTEK CORPORATION
Lightning Detection
LRX-1 Lightning Network Detector
ANT-50 Lightning Sensor / GPS
Installation/Operation Guide

LRX1ANT50-020819
B O L T E K L I G H T N I N G D E T E C T I O N
LRX-1 Lightning Network Detector
ANT-50 Lightning Sensor / GPS
Disclaimer
LRX-1 based lightning data is only approximate and should not be used for safety applications. Strike and
storm locations indicated and alarm statuses may be erroneous and should not be used to safeguard
personnel, equipment or data.
Neither Boltek Corporation nor its affiliates shall be liable to the purchaser of this product or third parties
for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of use, misuse,
accident, or abuse.
Notwithstanding the above Boltek Corp’s liability shall not exceed the purchase price of the equipment.
THIS EQUIPMENT IS NOT TO BE USED FOR SAFETY PURPOSES
USE OF THIS PRODUCT SHALL BE DEEMED TO BE ACCEPTANCE OF BOLTEK’S STANDARD TERMS AND
CONDITIONS (ENCLOSED AND AVAILABLE AT WWW.BOLTEK.COM). IF YOU DO NOT AGREE TO BE
BOUND BY THESE TERMS AND CONDITIONS PLEASE RETURN THIS PRODUCT TO THE PLACE OF
PURCHASE FOR A FULL REFUND.
©2021 Boltek Corporation
4 Stonebridge Dr. Unit 2
Port Colborne, ON. L3K 5V5
Canada
Email: info@boltek.com
Web: www.boltek.com
Phone (905) 734-8045 • Fax (905) 734-9049

LRX1ANT50-020819
FCC Compliance Statement
For United States Users
This equipment is tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio or television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause interference to radio and television reception, which can be determined by turning the equipment on and off,
the user is encouraged to try to correct the interference by one or more of the following measures.
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
WARNING
The connection of a non-shielded equipment interface cable to this equipment will invalidate the FCC Certification
of this device and may cause interference levels which exceed the limits established by the FCC for this equipment.
It is the responsibility of the user to use a shielded interface cable with this device. If this equipment has more than
one interface connector, do not leave cables connected to unused interfaces. Changes or modifications not
expressly approved by the manufacturer could void the user’s authority to operate the equipment.
For Canadian Users
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la class B respecte toutes les exigences du Règlement sur le materiel brouilleur du
Canada.

CAUTIONS
LRX-1 based lightning data is only approximate and should not be used for safety
applications. Strike and storm locations indicated and alarm statuses may be
erroneous and should not be used to safeguard personnel, equipment or data.
Install the ANT-50 Sensor on a calm clear day when no thunderstorms are expected.
If you are not experienced in safe antenna installation using appropriate safety
equipment you should refer installation to an experienced antenna installer.
(See Television Antennas or Satellite Antennas in the Yellow Pages)
LIGHTNING HAZARD
ANT-50 connections are not optically isolated from the roof mounted sensors.
Dangerous voltages may occur should lightning strike at or near the sensor.
ELECTROCUTION HAZARD
You can be killed if the ANT-50 mast or its mounting hardware comes in contact with
an electrical power line. WATCH FOR AND STAY AWAY FROM ALL OVERHEAD
WIRES.

Table of Contents
INTRODUCTION...........................................................................................................1
THEORY OF OPERATION ....................................................................................................3
INSTALLATION .............................................................................................................5
CONFIGURING THE LRX-1 ......................................................................................12
OPERATION..................................................................................................................19
MAINTENANCE...........................................................................................................21
TROUBLESHOOTING ................................................................................................23
SPECIFICATIONS ........................................................................................................25

Table of Figures
Figure 1: Lightning Detection Network Diagram
.........................................................................3
Figure 2: LRX-1 / ANT-50 Connection Diagram
.........................................................................6
Figure 3: Front View of LRX-1
.......................................................................................................9
Figure 4: Default LRX Configuration File
/home/lrx/LRX.ini ........................................13
Figure 5: Windows Device Manager
............................................................................................15
Figure 6: PuTTY Configuration
...................................................................................................16
Figure 7: LRX-1 Login Screen
......................................................................................................16
Figure 8: Editing the LRX.ini Configuration File using nano
...................................................17

C H A P T E R 1 - I N T R O D U C T I O N
1
Introduction
Congratulations on your purchase of a Boltek LRX-1 Lightning Detection Network
Detector.
LRX-1 lightning data is only approximate and should not be used for safety
applications. Strike and storm locations indicated and alarm statuses may be
erroneous and should not be used to safeguard personnel, equipment or data.
Chapter
1

C H A P T E R 1 - I N T R O D U C T I O N
2
The standard LRX-1 package contains the following items:
1: LRX-1
2: ANT-50 (Lightning
Sensor & GPS)
3: 10 Ft Network
Patch Cable
4: Lightning Sensor Cable
(CAT6)
5: GPS Cable (CAT6)
6: 120/220V Power
Adapter (N.A. or Int.)
7: 2 x Cable Grips
8: 3 x Large Mounting
Clamps
9: 3 x Medium
Mounting Clamps
Unpack your LRX-1 and check to ensure all parts listed are included before installation.

C H A P T E R 1 - I N T R O D U C T I O N
3
Theory of Operation
…
Figure 1: Lightning Detection Network Diagram

Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Sensor de seguridad de Boltek