PART II. Installing the System
1. Connect the source water valve and the water inlet with a tube.
2. Connect another tube to the drain hole of the unit and then run the other end of the drain
tube into the drainage.
3. Wall mount your unit or place it on the decided floor space.
4. Connect the power cord of the voltage rating that matches with that on the rating plate.
5. Filter flushing
The Filters must be flushed initially in the beginning before proceeding to use the Unit/Device for consumption/usage.
Flushing need to be done on External SF, Pre Carbon Filter ,Sediment Filter & Post Carbon Filter.
Steps to Flush the Filter Cartridges:
➢ Connect source water to External SF input and flush for 5-10 minutes.Then connect to the purifier.
➢ Remove the back cover of the device.
➢ Identify the particular filter cartridge and water flow direction as mentioned on the filter cartridge.
➢Pre-Carbon filter : Flush the Pre Carbon filter for 3-5 minutes. Now reverse tubing from input to output and flush for 3-5
minutes. Now again connect to input of the cartridge and flush for 3-5 minutes.
➢Sediment Filter : Remove the existing tubings. Connect the output of Pre Carbon filter to the input of the SF and flush for
the 10 minutes. Connect the tubing as per actual.
➢Post-Carbon filter : Now remove the output of the Post Carbon filter from UV and start the system and flush for the 3-5
minutes. Now connect the output of UF to the output of the Post carbon filter and flush it for 3-5 minutes. Again connect
the output of UF to input of Post Carbon filter and flush it for 3-5 minutes.
➢After the Flushing of the device Install the device with all the tubing in place with QC fittings tightly and all the Water Circuit
and Electrical Circuit in Place and good condition and charge the Device with power and water Supply.
6. Drain the tank two times.