Blue Seal Evolushion E512 Manual de usuario

For use in GB & IE
229356-5
ELECTRIC COOKTOP
E512
E514
E516
INSTALLATION AND OPERATION MANUAL

The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in
writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
© Copyright Moffat Ltd. September 2008.
MANUFACTURED BY
Moffat Limited
PO Box 10001
Christchurch
New Zealand
Ph: (03) 389 1007
Fax: (03) 389 1276
WORLD-WIDE BRANCHES
UNITED KINGDOM
Blue Seal
67 Gravelly Business Park
Gravelly Park
Birmingham
West Midlands
B24 8TQ
Ph: (121) 327 5575
Fax: (121) 327 9711
UNITED STATES
Moffat Inc
3765 Champion Blvd
Winston-Salem
North Carolina 27115
Ph: (336) 661 0257
Fax: (336) 661 9546
CANADA
Serve Canada
22 Ashwarren Road
Downview
Ontario M3J1Z5
Toll Free:800 263 1455
Ph: (416) 631 0601
Fax: (416) 631 0315
www.servecanada.com
www.moffat.com
NEW ZEALAND
Christchurch Auckland
Moffat Limited Moffat Limited
PO Box 10-001 4 Waipuna Road
16 Osborne Street Mt Wellington
Christchurch Auckland
Ph: (03) 389 1007 Ph: (09) 574 3150
Fax: (03) 389 1276 Fax: (09) 574 3159
AUSTRALIA
Victoria New South Wales
Moffat Pty Limited Moffat Pty Limited
740 Springvale Road 3/142 James Ruse Drive, Rose Hill
Mulgrave, Melbourne PO Box 913, Smithfield
Victoria 3171 Sydney, N.S.W. 2142
Ph: (03) 9518 3888 Ph: (02) 8833 4111
Fax: (03) 9518 3838 Fax: (02) 8833 4133
Western Australia Queensland
Moffat Pty Limited Moffat Pty Limited
67 Howe Street 30 Prosperity Place
Osbourne Park Geebung, Brisbane
WA 6017 Queensland 4034
Ph: (08) 9202 6820 Ph: (07) 3630 8600
Fax: (08) 9202 6836 Fax (07) 3630 8623

1
Blue Seal Electric Cooktop
E512 Electric Cooktop - 300mm.
E514 Electric Cooktop - 600mm.
E516 Electric Cooktop - 900mm.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification
General
Electrical Supply Requirements
Electrical Connection
Dimensions ................................................................................................ 5
Installation .............................................................................................. 10
Installation Requirements
Unpacking
Location
Clearances
Assembly
Fitting Adjustable Feet / Rear Rollers to Leg Stand Units
Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases
Electrical Connection
Commissioning
Operation ................................................................................................. 13
Operation Guide
Radiant Hotplates
Griddle Plates
Cleaning and Maintenance ...................................................................... 15
General
After Each Use
Daily Cleaning
Weekly Cleaning
Periodic Maintenance
Fault Finding............................................................................................ 18
Circuit Schematics ................................................................................... 19
Replacement Parts List............................................................................ 23
Contents

2
Introduction
We are confident that you will be delighted with your BLUE SEAL ELECTRIC COOKTOP, and it will become a
most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Blue Seal ELECTRIC COOKTOP, there are two
important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
WARNING:
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK
OF FIRE.
• THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
• ITIS RECOMMENDED THAT AREGULAR INSPECTION IS MADE BY ACOMPETENT SERVICEMAN TO ENSURE
CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
• DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
• DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
C
AUTION
:
This appliance is;
•
For professional use and is to be used by qualified persons only.
•
Only authorised service persons are to carry out installation, servicing and
conversion operations.
•
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
•
DO NOT operate the appliance without the legs supplied fitted.

3
Specifications
Model Numbers Covered in this Specification
E512D-B Bench Model 2 Open Radiant Elements.
E512C-B Bench Model 300mm Griddle.
E514D-B Bench Model 4 Open Radiant Elements.
E514D-CB with Cabinet Base 4 Open Radiant Elements.
E514D-LS with Leg Stand 4 Open Radiant Elements.
E514C-B Bench Model 2 Open Radiant Elements / 300mm Griddle.
E514C-CB with Cabinet Base 2 Open Radiant Elements / 300mm Griddle.
E514C-LS with Leg Stand 2 Open Radiant Elements / 300mm Griddle.
E514B-B Bench Model 600mm Griddle.
E514B-CB with Cabinet Base 600mm Griddle.
E514B-LS with Leg Stand 600mm Griddle.
E516D-B Bench Model 6 Open Radiant Elements.
E516D-CB with Cabinet Base 6 Open Radiant Elements.
E516D-LS with Leg Stand 6 Open Radiant Elements.
E516D-RB with Refrigeration Base 6 Open Radiant Elements.
E516C-B Bench Model 4 Open Radiant Elements / 300mm Griddle.
E516C-CB with Cabinet Base 4 Open Radiant Elements / 300mm Griddle.
E516C-LS with Leg Stand 4 Open Radiant Elements / 300mm Griddle.
E516C-RB with Refrigeration Base 4 Open Radiant Elements / 300mm Griddle.
E516B-B Bench Model 2 Open Radiant Elements / 600mm Griddle.
E516B-CB with Cabinet Base 2 Open Radiant Elements / 600mm Griddle.
E516B-LS with Leg Stand 2 Open Radiant Elements / 600mm Griddle.
E516B-RB with Refrigeration Base 2 Open Radiant Elements / 600mm Griddle.
E516A-B Bench Model 900mm Griddle.
E516A-CB with Cabinet Base 900mm Griddle.
E516A-LS with Leg Stand 900mm Griddle.
E516A-RB with Refrigeration Base 900mm Griddle.
Base Stand Options:
-B Bench Model (All Models).
-CB with Cabinet Base (E514 / E516 Models only).
-LS with Leg Stand (E514 / E516 Models only).
-RB with Refrigeration Base (E516 Models Only).
General
A commercial heavy duty, high efficiency Cooktop for modular kitchens, constructed in easy clean
stainless steel external finish. Hinge-up elements and griddle sections and all services are accessed
from the front of the units. It has a high option hob / griddle arrangement with 300mm, 600mm or
900mm griddle or open radiant element options.
It is available on industrial adjustable feet. With 3 models of base unit available from the E512 to
E516 models. (Model E514 is not available with Refrigeration Base option and Model E512 is only
available in Bench Model).

4
Specifications
Electrical Supply Requirements
Electrical Connection
Electrical supply connection point is located at the rear of the appliance, approximately 130mm from
the right hand side and 31mm from the rear of the appliance. 85mm from bench height on bench
models and 740mm from the floor on leg stand and cabinet base models. (Refer to the ‘Dimensions’
section).
When connecting a this electric appliance to the mains supply, ensure that the following is carried
out:-
• An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
• Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
• The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
• A grommet is fitted around the wiring entry hole into the appliance.
• All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
WARNING:
THIS APPLIANCE MUST BE EARTHED. IFTHE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY ASUITABLY
QUALIFIED PERSON IN ORDER TO AVOID AHAZARD.
For the Refrigeration Cabinet Specifications, refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
Model Power Supply Total Power
Input
Amps
Voltage Type Frequency L1 L2 L3
E512D 230-240 Vac 1 P+N+E 50 / 60 Hz 4.8 kW 20.0 --- ---
E512C 230-240 Vac 1 P+N+E 50 / 60 Hz 3.4 kW 14.2 --- ---
E514D 400-415 Vac 2 P+N+E 50 / 60 Hz 9.6 kW 20.0 20.0 ---
E514C 400-415 Vac 2 P+N+E 50 / 60 Hz 8.2 kW 14.2 20.0 ---
E514B 400-415 Vac 2 P+N+E 50 / 60 Hz 6.8 kW 14.2 14.2 ---
E516D 400-415 Vac 3 P+N+E 50 / 60 Hz 14.4 kW 20.0 20.0 20.0
E516C 400-415 Vac 3 P+N+E 50 / 60 Hz 13.2 kW 14.2 20.0 20.0
E516B 400-415 Vac 3 P+N+E 50 / 60 Hz 11.6 kW 14.2 14.2 20.0
E516A 400-415 Vac 3 P+N+E 50 / 60 Hz 10.2 kW 14.2 14.2 14.2

5
Dimensions
Dimensions for Bench Models
E514-B
E512-B
E516-B
= Rating Plate Location for this
option.
R
R

6
Dimensions
Dimensions for Cabinet Base Models
E514-CB
E516-CB
= Rating Plate Location for
this option.
R
R

7
Dimensions
Dimensions for Leg Stand Models
E514-LS
E516-LS
= Rating Plate Location for
this option.
R
R

8
Dimensions
Dimensions for Refrigerated Base Models
E516-RB
E512D
Cooktop Options
E512-C
For the Refrigeration Cabinet Operation refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
= Rating Plate Location for
this option.
R
R
Otros manuales para Evolushion E512
1
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Placa de cocina de Blue Seal

Blue Seal
Blue Seal Evolushion E512 Manual de usuario

Blue Seal
Blue Seal Blue Seal Evolution G518C-B Manual de instrucciones

Blue Seal
Blue Seal G512 Series Manual de usuario

Blue Seal
Blue Seal Evolution Series Manual de usuario

Blue Seal
Blue Seal G50-D Manual

Blue Seal
Blue Seal Blue Seal E512C-B Manual de instrucciones

Blue Seal
Blue Seal IN512 Manual de usuario

Blue Seal
Blue Seal G57 Manual de usuario

Blue Seal
Blue Seal Evolution G512 Manual de usuario

Blue Seal
Blue Seal Blue Seal E516A-B Manual de instrucciones