BLUE JAY MICO-RACE Manual de usuario

User Manual
Tel: +0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China
MICO-RACE
Wireless temperature monitor
User Manual
Version:2.1

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 1 -
Read me
When you use MICO-RACE wireless temperature monitor, be sure to read this
user manual carefully, and be able to fully understand the implications, the correct
guidance of operations in accordance with user manual, which will help you make
best use of MICO-RACE wireless temperature monitor, and help to solve the
various problems at the scene.
1. Before the MRR receiver turning on the power supply, be sure that the power supply
within the provisions of the instrument;
2. Be sure the MRR wiring consistent with the label marked;
3. MRS remote sensor must be installed in standard distance(less than 100m outside and
less than 20m in room), between sensor and receiver without electromagnetic
shielding layer;
4. Communication port (RS232/RS485 or Ethernet) is strictly prohibited to impose on high
pressure;
5. When commissioning on PC, please make sure use series port(RS232/RS485), or use
serial port simulation tools for conversion.
●Please read this user manual carefully
●Please save this document

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 2 -
Directory
CONTENTS Page
1. - Guide for MRR-E and software operation......................................... - 3 -
1.1- MRR-E wiring................................................................................. - 3 -
1.2-MRR-E configuration....................................................................... - 4 -
1.2.1- Part I: Ethernet Port configuration in MRR-E ........................ - 5 -
1.2.2- Part II: Ethernet Port configuration in MRR-ED..................... - 6 -
1.3. - How to use Microtemp Desktop ................................................... - 7 -
2. - Guide for MRR-R................................................................................ - 14 -
2.1- MRR-R wiring............................................................................... - 14 -
2.2- MRR-R configuration.................................................................... - 15 -
3.- Guide for MRR-M................................................................................. - 16 -
3.1- Front Panel Description................................................................ - 16 -
3.2- System configuration- GPRS router............................................. - 17 -
3.3.- Remote config & check MRR-M.................................................. - 20 -
4. - Access Blue Jay cloud software.......................................................... - 22 -
5.- Trouble shooting.................................................................................. - 23 -

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 3 -
1. - Guide for MRR-E and software operation
1.1- MRR-E wiring
Mico-Race data receiver MRR-E standard use RJ45 port(Ethernet connection) and
6~34VDC power supply;
Blue Jay Technology standard provide 12VDC 1A adapter.
MRR-E
Pictures
Notes:
Ethernet chip will emits some of heat in working, please make sure MRR-E device body in
cool and well-ventilated place!
Package list:
MRR-E
MRR-E device *1
12VDC 1A adapter *1
1.5m 433Mhz Antenna *1

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 4 -
1.2-MRR-E configuration
MRR-E has a built-in Ethernet chip for TCP/IP communication, and there have two version
of MRR-E, standard MRR-E do not support DHCP, advanced MRR-ED type with DHCP
function, please follow the guide step for initial configuration:
1:Close the firewall of your computer system.
2: Please disable the excess NIC(Network Interface Card) in your PC or wireless NIC in
your laptop, leave only one physical NIC connected to MRR.
3: Connect the MRR-E to the Ethernet Router and power ON; please make sure your PC
in same network.
4: Use the configuration software TCP232-E45_V1.4.2(DHCP types) or
TCP232-T24_V5.1.0.1(Standard types) for initial configuration
Ethernet chip had done the initial setting, default parameter as following:
Module IP: 192.168.0.7
Subnet mask: 255.255.255.0
Default Gateway: 192.168.0.1
Destination IP: 192.168.0.2
Destination Port: 16254

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 5 -
1.2.1- Part I: Ethernet Port configuration in MRR-E
Use [TCP232-T24-V5.1.0.1]
Step 1: Run [USR-TCP232-T24 V5.1.0.1.exe] in your PC, press button Search in LAN,
software will auto scan your network to find MRR-E device, device shown in right
box:
Step 2: Double click the searched device can read the configuration parameters in left
chart:
Step 3: Please change the following configuration:
Module IP:
Assign the MRR-E device IP to any one you like in your sub-network, do
not duplicate existing equipment, otherwise there will be a network error.
Default Gateway:
Change Gateway IP that matched with your network setting.
Notes: if you purchase DHCP type please see Part II
Destination IP
Destination port
Change the IP and TCP port that direction to your PC run [Microtemp]
Notes:Please do not change other parameter in Ethernet Port, or MRR-E may unable to
work.
Step4: Press button Set selected item via LAN to end the Set

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 6 -
1.2.2- Part II: Ethernet Port configuration in MRR-ED
Use [TCP232-E45_V1.4.2]
Step1- Press Search Device button for auto find the MRR device
Step2- Choose the MRR device in lists, software will update the device configuration info
Step3- If MRR-E connects to router, you can choose DHCP mode, please make sure
your router can assign IP; if connected directly to host PC, please chose Static IP
mode, and configuration the MRR Ethernet gateway & IP address related your
host PC setting.
Note: Only Port0 is available, and do not change other parameter in Ethernet Port, or
MRR-E may unable to work.
Please do not change the Baud rate(9600)or MRR will not work

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 7 -
1.3. - How to use Microtemp Desktop
Blue Jay Technology provide standard local software "Microtemp.exe" for MRS sensor
setting and test operation, it provide MRS parameter configuration and basic monitor &
record on your Desktop PC, please follow the guide to start.
Notes: Software only have Chinese character, if the software displayed shows garbled
code, please install the windows Chinese Language Pack.
Run "Microtemp.exe" to show temperature data from MRS in your PC
Step 1: Set communication parameter
Click COMM Config, software will automatic detect LAN IP of your PC and show in the
dialog window, please make sure the IP same as preset "Destination IP" in Chart 1.2.1
or Chart 1.2.2, then input the preset " Destination port" (in example we use default is
16254), after that click OK:

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 8 -
Step 2: Add MRS sensor
Click Add MRS,you can add MRS sensor in record list, please make sure your MRS
types, and input the ID on the MRS label, then click OK; repeat this step until all the MRS
sensor added:

User Manual
Tel:+0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China - 9 -
Step 3: Start operation
Click RUN in toolbar, then switch to "Raw_data" page, you should see a upload command,
it contain MRR ID inside, mean connection success. Otherwise, the connection is
unsuccessful, please check the connection of MRR-E or configuration in Chart 1.2.1 or
Chart 1.2.2:
Step 4: basic configuration
In "Curve" page, click each MRS line, you can see record curve drawn by latest 10 record
point. also you can see the "Basic Config" table in the right part of screen. detail of each
parameter please refer to the " Mico Race Data Format_1.6 "
Tabla de contenidos