BLACK DECKER BDT20WTB Manual de usuario

INSTRUCTION MANUAL
PORTABLE DEHUMIDIFIER
Thank you for choosing BLACK+DECKER!
PLEASE READ BEFORE RETURNING THIS PRODUCT FOR
ANY REASON.
If you have a question or experience a problem with your BLACK+DECKER
purchase, go to www.blackanddecker.com/instantanswers
If you can’t find the answer or do not have access to the Internet, call
844-299-0879 from 10:30 a.m. to 6:30 p.m. EST Mon. - Fri. to speak with an
agent. Please have the catalog number available when you call.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
CATALOG NUMBER
BDT20WTB
BDT30WTB
BDT40WTB
BDT50WTB
BDT50PWTB

Page 2
Thank you for purchasing our
BLACK+DECKER product. This
easy-to-use manual will guide you
in getting the best use of your
portable dehumidier.
Remember to record the model
and serial numbers. They are on a
label on the rear.
Staple your receipt to your manual.
You will need it to obtain warranty service.
Model number
Serial number
Date of purchase
PRODUCT REGISTRATION
CONTENTS
SAFETY INFORMATION
Important Safety Instructions..........................................................................................................................................3-4
Grounding Instructions.........................................................................................................................................................4
Safety Guidelines ....................................................................................................................................................4
Power Cord Operation..........................................................................................................................................4
SET UP & USE
Parts & Features ....................................................................................................................................................................... 5
Control Panel............................................................................................................................................................6
Installation Guide .................................................................................................................................................... 7
Before First Operation.......................................................................................................................................... 8
Operation Instructions.................................................................................................................................... 9-14
Specications ..........................................................................................................................................................15
CLEANING & CARE..............................................................................................................................................16
TROUBLE SHOOTING & WARRANTY
Before You Call For Service...............................................................................................................................17
Customer Service...................................................................................................................................................17
Troubleshooting ...............................................................................................................................................18-19
Limited Warranty.................................................................................................................................................................. 20

Page 3
SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS
1. Always place the unit on a level surface strong enough to support
the unit with a full bucket of water
2. Never use or store gasoline or other ammable vapor or liquid near
this unit
3. Minimum installation clearance: 11.8 inches around the unit and 17.7
inches above the unit. Do not block or cover air inlet or outlet grills.
4. The unit must be connected to a correctly grounded power supply.
5. Do not start or stop the unit by inserting or pulling out the power
plug.
6. Do not use an adapter plug or extension cord.
7. Do not use the unit in the immediate surroundings of a bath, a
shower, swimming pool or clothes dryer.
8. Do not insert anything into the air outlet.
9. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similar qualied person in order to
avoid a hazard.
10. When cleaning the unit, always turn the unit off and unplug the
power cord.
11. Do not use outdoors. Intended for indoor use only.
12. Place the dehumidier in an area where the temperature will not fall
below 41˚ Fahrenheit. The coils can become covered with frost if the
room temperature is too low, which may reduce performance.
13. The appliance shall be installed in accordance with national wiring
regulations.
14. The appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
SAVE THESE INSTRUCTIONS
HOUSEHOLD USE ONLY
WARNING
WARNING - Hazards or unsafe
practices which COULD result in
severe personal injury or death
DANGER
DANGER - Immediate hazards
which WILL result in severe
personal injury or death
CAUTION
CAUTION - Hazards or unsafe
practices which COULD result in
minor personal injury
WARNING
When using electrical appliances, basic safety precautions
should be followed, including the following

Page 4
SAFETY INFORMATION
GROUNDING INSTRUCTIONS
ELECTRICAL REQUIREMENTS
The electrical requirements are a 115 volt 60 Hz, dehumidier only, 15 amp. It is
recommended that a separate circuit serving only the product be provided. The
product is equipped with a 3-wire cord having a 3-prong grounding plug. It must
be plugged into a wall receptacle that is properly installed and grounded.
This appliance must be grounded. In the event of an electrical short circuit,
grounding reduces risk of electric shock by providing an escape wire for the
electric current. The cord provided with this appliance is equipped with a
grounding wire and a grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded.
Avoid the use of three prong adapters or cutting off the third grounding prong
in order to accommodate a two prong outlet. This is a dangerous practice since
it provides no effective grounding for the air conditioner and may result in shock
hazard.
Consult a qualied electrician or serviceman if:
1) The grounding instructions are not completely understood.
2) You are unsure that the appliance is properly grounded.
3) You have any questions about the grounding or electrical instructions.
POWER SUPPLY CORD
1. Avoid the use of an extension cord because of potential safety hazards under
certain conditions. Have a qualied electrician or serviceman to install an
outlet near the appliance.
2. If it is absolutely necessary to use longer cord sets or an extension cord,
extreme care must be exercised.
a) Use only a grounding type 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will accept the plug on the
appliance.
b) The marked electrical rating of the cord set or extension cord must equal
to or greater than the electrical rating of the appliance. The longer cord
should be arranged so that it will not drape over the counter top or table
top where it can be pulled on by children or tripped over unintentionally.
NOTE: Neither BLACK+DECKER nor the dealer can accept any liability for damage to the
product or personal injury resulting from failure to observe the electrical connection
procedures.
WARNING
Improper use of the grounding plug can result in a risk
of electric shock.

Page 5
PARTS & FEATURES
Control Panel & Digital Display
Air Outlet
Water Collection Bucket
Water Level Indicator
Castors (4)
Handle
SET UP & USE
Drain Plug
Filter
Continuous Drain Kit
Additional Pump Drain Kit
(Model BDT50PWTB Only)
Drain Hose
Pump Drain Hose (16.4 ft)
Drain Adapter & Gasket
Pump Adapter & Gasket

Page 6
CONTROL PANEL
Clean Filter
LED Indicator
Timer ON
LED Indicator
Pump LED
Indicator (Model
BDT50PWTB)
SET UP & USE
High Fan Speed
LED Indicator
Continuous
Drain LED
Indicator
Digital
Humidistat
Display
Filter
Button
Fan
Speed
Button
Pump Button
(Model
BDT50PWTB)
Timer Button
Increase Room
Humidity Level Decrease Room
Humidity Level
Power Button
ERROR CODES: (Will appear in the digital humidistat display)
E1: The temperature sensor on the discharge pipe may be faulty and may need to
be changed.
E2: The temperature sensor on the heat exchanger may be faulty and may need
to be changed.
E3: If the E3 error code is shown on the digital display, check to make sure the
room temperature is below 90˚F. If the room temperature is too high, place
the dehumidier in a location where the room temperature is below 90˚F for at
least 2 hours before operating again. If the E3 code appears again, contact the
customer service department.
EH: The humidity sensor may be faulty and may need to be changed.
P1 (Model BDT50PWTB): Bucket is not in the proper position. Make sure the
bucket is in place and securely seated for the dehumidier to operate. If error
code reappears after adjusting the bucket, please contact the customer service
department.
E5 (Model BDT50PWTB): The pump drainage kit may not be installed before
start pump function or users use non-standard drainage pipes. (Manufacturer's
original pipe), or the drain cover is not tightened, or the rubber washer is
missing, or poor connection between drain pipe and drain cover.
If any of these error codes appear and remain in the display, please contact the
customer service department as listed on page 18 of the user manual.
Timer OFF
LED Indicator
Bucket Full
LED Indicator
P
P

Page 7
INSTALLATION GUIDE
When you open the box, you should have received:
Portable dehumidier
User Guide
Castors (4)
Continuous Drain Kit
If you purchased a model with a pump (BDT50PWTB) there will be an additional
pump drain kit
To Install Castors:
1. For the 20 pint model (BDT20WTB) and the 30 pint model (BDT30WTB)
gently lift the lid of the bucket (see g 1).
For the 40 pint model (BDT40WTB) and the 50 pint models (BDT50WTB,
BDT50PWTB) gently lift off the lid of the bucket (see g 2). Do not pull on handle.
2. Tilt the dehumidier no more than
45 degrees and push to insert the castors
into the base of the unit. Make sure the ring
around the castor is ush against the
bottom of the dehumidier. (see g. 3).
SET UP & USE
Fig. 2
Fig. 3
Fig. 1
Bucket
lid
Hole
Buckle lid
Float
1.Using two hands gently remove lid
from the top of the bucket.
2.Remove casters
from bucket
3.Re-install the lid and be
sure that it is securely
clipped into the bucket
Important Note: Verify the plastic float
system on the top of the bucket is still
securely installed and swinging properly
before placing bucket back in the
dehumidifier
Cast or s and
other accessories
DE T
Cast or s and
other accessories

Page 8
BEFORE FIRST OPERATION
1. Grip each side of the bucket and pull to remove the bucket from the
dehumidier (Fig. 4).
2. Check inside the bucket to make sure the oat system is in the correct
position. If not, place the oat in the correct position (Fig. 5).
3. Re-insert the bucket once you have determined the oat system is in the
correct position (Fig. 6)
The oat in the bucket is essential to the “bucket full” system working properly.
Do not remove the oat and make sure the oat can rotate freely.
SET UP & USE
Fig. 4
Fig. 5
Fig. 6

OPERATION INSTRUCTIONS
NOTE: Unit may shut off automatically during 24 hour period if collection bucket
is full (see below). If continuous drainage mode is utilized, and drain hose
is connected, the unit will operate continuously (see page 12).
1. Press the POWER button once to turn the unit on. Press POWER button again
when you’re ready to turn it off.
2. Press the or buttons under the display to select the desired relative
humidity in the room. Each press will change the room humidity by 5%. The
room humidity is selectable from 35-80% or continuous. The unit will cycle on
and off to maintain the humidity level chosen on the digital display. After few
seconds, it will display the ambient humidity. When the ambient humidity is
lower than the set humidity, the compressor will stop running, and after few
minutes the fan will stop running.
3. If you want the dehumidier to operate continuously regardless of the room
humidity, press button until you see “CO” on the display. This will enable
continuous operation and the indicator will light up on the control panel.
4. Press the FAN SPEED button to select between High and Low Speeds. If HIGH
speed is selected the indicator will light up.
TIMER FUNCTION
To program the unit to automatically turn ON, press the TIMER button when
the unit is OFF. Press the or to increase the timer in 30 minute increments
up to 10 hours. After 10 hours, each press of the will increase the timer in 1
hour increments up to 24 hours. Once the desired time is reached, the unit will
automatically turn ON.
To program the unit to automatically turn OFF, press the TIMER button when
the unit is ON. Each press of the or buttons will change the timer setting
in 30 minute increments up to 10 hours. After 10 hours, each press of the or
buttons will increase or decrease the timer in 1 hour increments up to 24 hours.
Once the desired time is over, the unit will automatically power OFF.
FULL WATER COLLECTION BUCKET
When the water collection bucket is full, the unit will shut off automatically, make
a beeping noise and the BUCKET FULL indicator will light. The dehumidier will
not run again until the bucket is emptied and properly placed back inside the
unit.
SET UP & USE
Page 9

Page 10
NOTE: When the bucket is full or removed from the unit, the compressor will turn
off but the fan will continue to run for a few minutes. This is completely
normal. The dehumidier will not be removing moisture from the air at
this time.
Over time, the dehumidier will create a more stable humidity in the area it is
located.
The more moisture the dehumidier removes from the air, the more often you
may have to empty the bucket unless you choose to use the continuous drain
option. The number of times the bucket will need to be emptied daily will depend
on the dehumidier model.
CAUTION: Do not place the water collection bucket on the oor when it is full as
it is uneven on the bottom and may spill.
SET UP & USE
BDT20WTB 20 pints of moisture
removed every 24 hours
empty maximum of 3 times
per day
BDT30WTB 30 pints of moisture
removed every 24 hours
empty maximum of 4 times
per day
BDT40WTB 40 pints of moisture
removed every 24 hours
empty maximum of 3 times
per day
BDT50PWTB/
BDT50WTB
50 pints of moisture
removed every 24 hours
empty maximum of 4 times
per day
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Idiomas:
Otros manuales de Deshumidificador de BLACK DECKER