
8
“Power Inflation”
When you push “IN” button,
air is supplied in the float.
Check whether air is supplied
in float only while pushing the
button.
“Oral Inflation”
Hold a mouthpiece of an
inflator in your mouth firmly, if
you push oral button only
while blowing a breath, air is
supplied into a float. Check
whether air is supplied
certainly.
■Air supply operation
■Exhaust operation
[ Note ]
○Please refer to Page 11 for underwater exhaust operation.
“Deflation by ORAL Button”
When “ORAL” button is
pushed, the valve in the
inflator will be released and
the air in float will fall out
through the mouthpiece. Put
air in a float about 80% and
check whether air is exhausted
only while you push the
“ORAL” button.
"Pull Dump Deflation"
Pulling down the inflator body
will release the valve in the
shoulder housing and let the
air in the float exhaust. Put air
in a float about 80% and check
whether air is exhausted only
while you pull the inflator.
“Power Inflation”
When you push “IN” button, air is
supplied in the float. Check
whether air is supplied in float
only while pushing the button.
“Oral Inflation”
Hold a mouth piece of an inflator
in your mouth firmly, if you push
oral button only while blowing a
breath, air is supplied into a float.
Check whether air is supplied
certainly.
■Air supply operation
■Exhaust operation
Warning
●Exhaust by the “OUT” button is
performed only when an inflator
is set up correctly and air is in
a tank. Air is not supplied
when there is not enough air.
●Please do not pull combination
valve. It causes of breakage and
also operation failure.
[ Note ]
○If you perform the exhaust with the “OUT” button (Power
Deflation), a little air will be exhausted from the root of the “OUT”
button, but it is not failure.
○Please refer to Page 11 for underwater exhaust operation.
“Power Deflation”
When “OUT” button is pushed,
the valve in the housing on a left
shoulder will be released and the
air in float will fall out. Put air in a
float about 80% and check
whether air is exhausted only
while you push the button.
“Deflation by ORAL Button”
When “ORAL” button is pushed,
the valve in the inflator will be
released and the air in float will fall
out through the mouth piece. Put
air in a float about 80% and check
whether air is exhausted only
while you push the “ORAL” button.
1
2
1
2
1
2
1
2
BASIC OPERATION OF AIR SUPPLY EXHAUST & ACTUATION CHECK
Inflator Operation of Air Supply・Exhaust & Actuation Check
Warning
●Air supply by the “IN” button of an inflator (Power Inflation) is performed only when an inflator is set up correctly and air is in
a tank. Air is not supplied when there is not enough air.
●Please do not give a strong shock against an inflator. It causes of breakage and also operation failure.
●When abnormalities are found in the following check, please stop use and consult with your original dealer or authorized
distributor of our company.
Caution
●Please do not continue exhaust operation in the state that there is no air in float of B. C. during diving. A lot of water may
come in the float of B. C.
□Actuation check (In the case of JA3610 combination valve) □Actuation check (In the case of JA3620 standard valve)