Biamp RED-1 Manual de usuario

Biamp Systems, 9300 SW Gemini Drive, Beaverton, OR 97008 U.S.A. (503) 641-7287 www.biamp.com
Audia®& Nexia®
RED-1 & RED-1F
Operation/Installation
Manual

2
TABLE OF CONTENTS
REMOTE ETHERNET DEVICE 1 (RED-1) FEATURES.......................................3
Setup and Use .....................................................................................3
FRONT PANEL ....................................................................................4
Display ...........................................................................................4
Capacitive-touch Scroll Wheel........................................................................4
BACK PANEL .....................................................................................5
Connectors........................................................................................5
SET UP ...........................................................................................6-8
Device Setup Mode .................................................................................6
Edit Network Conguration ..........................................................................7
Edit Lock Code ....................................................................................7
Edit Display Brightness .............................................................................8
Edit Timeouts .....................................................................................8
View Device Information.............................................................................8
Exit ..............................................................................................8
INSTALLATION................................................................................9-12
SPECIFICATIONS................................................................................13
WARRANTY ......................................................................................14

3
REMOTE ETHERNET DEVICE 1 (RED-1)
RED-1 Remote Ethernet Device is a remote control for Audia®and Nexia®systems. It offers a simple, intuitive interface for end users and
can be installed and congured to t the unique needs of a particular application. The device connects via standard Ethernet cabling and is
powered over Ethernet, eliminating the need for custom cabling and local power sources. Multiple remote control panels can be connected
over large distances using standard network technology.
Features
Adjustment and/or initiation of up to 32 selectable system volumes and actions•
Volumes are any individual or grouped system levels, including inputs, outputs, matrix cross-points, etc.•
Actions are any individual or grouped system operations, including presets, source selection, mutes, ducking, combining, etc.•
Control functions are programmed in the Audia and Nexia system design software •
High contrast OLED (Organic Light-Emitting Diode) display with a wide viewing angle•
The display brightness can be adjusted to t the ambient light present in the application and can automatically dim when not in use•
Capacitive touch technology eliminates protruding and moving parts to increase product reliability and longevity while •
simplifying cleaning
RED-1 surface mounts or ush mounts to most walls with a wide variety of mounting holes to accommodate standard US and •
international back boxes. RED-1F ush-mounts to any wall; mounts using the retrot plate (included) or installs in a Raco®254
box for North American installation (not included).
330' (100m) Ethernet cable length can be extended with standard PoE network technology (routers, switches, hubs, •
media converters)
Connects with standard RJ45 or insulation displacement connector (IDC)•
Covered by• Biamp Systems’ ve-year warranty
RED-1F RED-1

4
RED-1 FRONT PANEL
Setup and Use
The Audia and Nexia software provides an intuitive interface for setup and programming of the RED-1. The information supplied by this
manual relates to physical connections and device setup. For more details on software setup, please consult the Audia or Nexia Help File.
Display
A graphic OLED (Organic Light-Emitting Diode) display with white characters on a black background shows a list of all control items avail-
able from that panel, as well as the last selected item. If a control item includes a volume control assignment, the bottom of the display will
show a graphical representation of a volume bar with the current level indicated to the right (percentage of maximum level).
Capacitive-touch Scroll Wheel
The capacitive-touch sensor provides a sleek interface for menu navigation and selection. The glossy-nish nger groove allows for scrolling
through and selecting available control items, as well as adjusting volume.
Select
Latch
Scroll

5
RED-1 BACK PANEL
Connectors
Two Ethernet connectors—one rear-facing RJ45 and one top-facing insulation displacement connector (IDC)—are provided for
connecting to the network. Only one connector may be used. The RJ45 and IDC utilize unshielded twisted pair (UTP) wiring to connect
to an Audia or Nexia system. This connection is made to the Ethernet port of an Audia or Nexia unit, either directly (single station)
or via a network switch, and carries control data over Ethernet.
The RED-1 is powered using IEEE 802.3-2008 Power over Ethernet protocol as Class 1 devices. Either a PoE-capable network switch
or a PoE injector is required to power the device; there are no other provisions for power inlet.
RED-1
Ethernet switch
with PoE
RED-1
Ethernet switch
without PoE
AC Power
PoE
injector

6
RED-1 SET UP
Device Setup Mode
The RED-1 can be congured without connecting to a functional Audia or Nexia network. To enter setup mode, connect the RED-1 to a
PoE source and place the jumper or any metal object across the locksmith pins. When conguration is complete, remove the jumper and
attach it to only one pin to resume normal operation. Please note: many of the conguration settings can be accessed via the Audia or
Nexia software.
The cursor has two modes: select and modify. In select mode, the cursor appears as a gray box. When scrolling through the available
items in the list, the gray box will highlight the current selection.
On elds that can be modied, use the Select button to transition to and from modify mode. In modify mode, the cursor appears as an
outline box. Use the scroll wheel to adjust the setting up or down.
Some screens have additional buttons that are used to accept (OK), reset, or cancel changed settings. Use the scroll wheel to navigate
the cursor to these buttons and press the Select button. The OK button saves the setting and exits the screen. The Reset button clears
the setting and does not save it. The Cancel button exits the screen without saving the setting.
Locksmith: Bridge jumper
pins to enter setup mode
“Select” mode in device
setup menu
“Modify” mode in device
setup menu

7
RED-1 SET UP
Edit Device ID
To name the unit, scroll to the ID Tag icon and press the Select button. Use the scroll wheel and Select button to choose the desired
characters. The Device ID must match that of a corresponding block in the Audia or Nexia design. More than one unit may be identied
with the same design block (same ID). Device IDs may also be assigned via Device Maintenance in the Audia or Nexia software.
Edit Network Conguration
To edit the network conguration, scroll to the Network icon and press the Select button. The default setting (Static) initializes the
IP address to 192.168.1.201, network mask to 255.255.255.0, and gateway to 0.0.0.0. These default settings allow RED-1 to be discovered
by an Audia or Nexia device that also has default settings. Network settings may also be assigned via Device Maintenance in the Audia
or Nexia software.
Edit Lock Code
To set password protection, scroll to the Key icon and press the Select button. Use the scroll wheel and Select button to choose the desired
characters. During normal operation, holding down the Select button for two seconds will lock the unit, and the user will be prompted for
the Lock Code before obtaining access. Lock Codes may also be assigned via Device Maintenance in the Audia or Nexia software.

8
RED-1 SET UP
Edit Display Brightness
To change the brightness of the OLED panel, scroll to the Display Brightness icon and press the Select button. Use the scroll wheel
and Select button to make adjustments. The rst setting represents the normal operational display brightness, and the second setting
represents the dim display brightness. Display brightness cannot be assigned via Device Maintenance in the Audia or Nexia software.
Edit Timeouts
To change the lock, dim, and sleep timeouts, scroll to the Timeout icon and press the Select button. Use the scroll wheel and Select
button to make changes. For lock and dim, the timeout can be none or range from 5 seconds to 30 minutes; for sleep, the timeout cannot
be none. Timeouts may also be assigned via Device Maintenance in the Audia or Nexia software.
View Device Information
To view information about the unit, scroll to the Information icon and press the Select button. The Serial Number, MAC Address,
Firmware Version, and System ID are displayed. This is read-only information. The Serial Number is helpful in identifying physical units/
locations when naming them via Device Maintenance in the Audia or Nexia software. Press the Select button again to exit this screen.
Exit
To exit the setup screen, scroll to the Exit Door icon and press the Select button.

9
RED-1 INSTALLATION
Surface Mount Installation
The RED-1 surface mounts to most walls and has a wide variety of mounting holes that accommodate standard US and International
back boxes.
Use a screw driver or other suitable tool to engage the latch at the bottom of the RED-1 to detach the back enclosure. When installing
the RED-1 using the RJ45 connector, guide the Ethernet cable through the rear opening before attaching the RED-1 to the wall. Connect the
RJ45 and snap the front enclosure into the retention holes. When installing the RED-1 using the IDC, use a drill bit to create a hole
in the top, side, or rear of the back enclosure along the indentations. Remove the Ethernet cable jacket and shielding.
84mm 3.3"
USA, Japan, Australia EUR
including Germany, Sweden,
UK, Netherland
60mm
2.36"
Italy
84mm
3.3"
Indentations
Wire here for use with IDC

10
RED-1 INSTALLATION
Flush Mount Installation
The RED-1F may be ush mounted using the retro-t plate (provided with the product) or a Raco™ 254 box (purchased from an electrical
distributor). To install the RED-1F, a hole must be cut in the wall to accommodate the Raco™ 254 back-box or to use the retro-t plate. See
the gures below.
SECTION A-A
SECTION A-A
11.75cm
12.07cm
4 5/8″
4 3/4″
Wall cut out dimensions
Mounting using a Raco™ 254 back box Mounting using the retro-t plate